• Nie Znaleziono Wyników

Badanie właściwości metrologicznych elektrod jonoselektywnych typu solid contact z wybranymi warstwami mediacyjnymi

N/A
N/A
Protected

Academic year: 2021

Share "Badanie właściwości metrologicznych elektrod jonoselektywnych typu solid contact z wybranymi warstwami mediacyjnymi"

Copied!
1
0
0

Pełen tekst

(1)

Analit 2 (2016) 130

130 Strona czasopisma: http://analit.agh.edu.pl/

Badanie właściwości metrologicznych elektrod

jonoselektywnych typu solid contact z wybranymi

warstwami mediacyjnymi

Investigation of the metrological parameters of the solid contact ion

selective electrodes (SC-ISE) with different solid contacts as ion to

electron transducers

Dominika Trela

[a]

, Migdalski Jan

[a]

[a] AGH Akademia Górniczo-Hutnicza, Wydział Inżynierii Materiałowej i Ceramiki, al. Mickiewicza 30, 30-059 Kraków, Polska

ABSTRAKT: Celem pracy było wykonanie elektrod jonoselektywnych typu solid contact wykazujących czułość w stosunku do jonów potasowych, chlorkowych i wodorowęglanowych w oparciu o własne warstwy mediacyjne i komercyjne jonoselektywne membrany. Badano właściwości metrologiczne elektrod np.: powtarzalność i stabilność potencjału standardowego, nachylenie charakterystyki, czas odpowiedzi, a także czas życia.

Docelowo, elektrody będą przeznaczone do ilościowego oznaczania jonów K+, Cl- i HCO

3- w ciekłych tkankach

oraz płynach ustrojowych człowieka. Wszystkie jonoselektywne elektrody solid contact z warstwą mediacyjną wytwarzaną w oparciu o bromkowe i chlorkowe sole srebra, sodu i/lub potasu, pokryte komercyjnymi membranami czułymi na jony potasowe i chlorkowe charakteryzowały się stabilnym, powtarzalnym potencjałem standardowym, nachyleniem zbliżonym do Nernstowskiego oraz szybkim czasem odpowiedzi. Próby przystosowania wspomnianych powyżej warstw mediacyjnych dotowanych dodatkowo kwaśnymi węglanami do współpracy z membranami zawierającymi różne jonofory węglanowe zakończyły się niepowodzeniem. Otrzymywane w ten sposób jonoselektywne elektrody solid contact wykazywały w trakcie kalibracji, w roztworach kwaśnych węglanów, również czułość kationową. Nieselektywną odpowiedź na zmiany stężenia kwaśnych węglanów obserwowano dla elektrod z membranami zawierającymi jonofor chlorkowy lub mieszaninę jonoforu chlorkowego i węglanowego po ich uprzednim kondycjonowaniu w roztworze NaHCO3.

ABSTRACT: The main aim of the study was fabricating the solid contact ion selective electrodes (SC-ISE) sensitive to potassium, chloride and bicarbonate ions with the use of different kinds of solid contacts as ion – to – electron transducers and commercial membranes sensitive to above mentioned ions. Metrological parameters such as slope, repeatability, stability of the potential, response time and lifetime of the electrodes were investigated.

The purpose of the study was to obtain electrodes that could be used in the future measurements of concentration of K+, Cl- and HCO3- ions in body fluids.

Electrodes with solid contacts based on bromide or chloride salts of silver, sodium and / or potassium covered with commercial membranes sensitive to potassium or chloride ions exhibited repeatability of potential, Nerstian response, fast response time and long – term potential stability. Attempts to the use of the solid contacts mentioned above (containing additionally bicarbonate ions) with ion selective membranes with different ionophores failed. These electrodes, during the calibration process in bicarbonate solutions, exhibited cationic sensitivity. On the other hand, the electrodes with chloride ionophore or mixture of chloride and bicarbonate ionophore exhibited nonselective response to bicarbonate concentration changes after conditioning process in NaHCO3 solution.

Cytaty

Powiązane dokumenty

A first-principles relativistic many-body investigation of magnetic hyperfine fields has been carried out for the ground states 4 2 S 1/2 of the alkali atom K and doubly charged ion

[r]

Selective embryo termination was performed at 7 weeks of gestation by local ultrasound guided injection of KCl into the GS implanted in the caesarean scar.. After the procedure

Computed tomogra- phy angiography revealed the presence of dis- seminated, hyperdense deposits in segmental and subsegmental branches of both pulmonary arteries (Figure

Six fresh solutions of Fludarabine Teva® were prepared by dilution of 1700 μl of concentrate with 100 ml of sodium chloride 0.9% to a final fludarabine phosphate concentra- tion

The selectivity of electrodes made of sodium-alluminium silica glasses, indicating sodium or potassium function, depends essentially only on the ratio Na20/A1,O^ or.. Na+/ Al * +

with allergic contact dermatitis due to both the active drug, Dorzolamide, and the excipient benzalkonium chlo- ride 0.1%.. The eye drops were suspended and switched to an

Najważniejsze z nich to: Studio nad życiem i działalnością naukową Mariana Raciborskiego - sesja z okazji 120 rocznicy urodzin uczonego (Kraków, Biblioteka Instytutu Botaniki PAN