• Nie Znaleziono Wyników

Badania struktury i własności fizykochemicznych Ti i stopu Ti6Al4V ELI stosowanych na implanty w protetyce stomatologicznej; Examination of structure and physicochemical properties of Ti and Ti6Al4V ELI alloy used for implants in dental prosthetics - Digi

N/A
N/A
Protected

Academic year: 2021

Share "Badania struktury i własności fizykochemicznych Ti i stopu Ti6Al4V ELI stosowanych na implanty w protetyce stomatologicznej; Examination of structure and physicochemical properties of Ti and Ti6Al4V ELI alloy used for implants in dental prosthetics - Digi"

Copied!
2
0
0

Pełen tekst

(1)

POLITECHNIKA ŚLĄSKA

WYDZIAŁ MECHANICZNY TECHNOLOGICZNY

PRACA DOKTORSKA

Badania struktury i własności fizykochemicznych Ti i stopu

Ti6Al4V ELI stosowanych na implanty w protetyce stomatologicznej

mgr inż. Sonia Loska

PROMOTOR

Prof. dr hab. inż. Zbigniew Paszenda

(2)

Examination of structure and physicochemical properties of Ti

and Ti6Al4V ELI alloy used for implants in dental prosthetics

Abstract

The work presents the results of numerical simulations and research on issues of shaping the functional properties of prefabricated endodontic posts, the applied metallic biomateri-als and conditions of their surface treatment. In preliminary considerations for selected ge-ometric form of prefabricated endodontic posts numerical analysis was performed with the use of the finite element method. On this basis, the state of displacements and stresses in the post and core - tooth configuration and forces at the border of the post - layer of dental cement connection were analyzed. The analysis was the basis for selection of mechanical properties of the material used to manufacture the conventional endodontic posts.

Two metallic biomaterials: CP Grade 4 Ti and Ti-6Al-4V ELI were selected. At first, several studies of initial material and technology of the surface modification were conducted. The surface modification was realized by means of a jet machining, and an electrochemical method. Then the usefulness of the selected methods of surface modification was verified in electrochemical, mechanical and surface topography studies. On the basis of the electro-chemical research the corrosion resistance of the selected metallic biomaterials in the initial state and with the modified surface was estimated (resistance to pitting and crevice corro-sion, electrochemical impedance spectroscopy).However, in the context of mechanical test-ing, dental cement adhesion to the modified surface of the metallic biomaterial was exam-ined. The topography of the surface-modified metal biomaterials with the use of the optical profilograph was also analyzed.

The conducted research shows the link between the structure quality and physico-chemical properties of biomaterials surface with the terms of conducting surface treatment of fixed dentures used in dental prosthetics.

Cytaty

Powiązane dokumenty

In the past, the bi-layer coating was prepared [47] by gas oxidation of titanium alloy and then electrochemical oxidation resulting in nanotubular layers grown on the previous

There is presented laser treatment with remelting and/or alloying of X40CrMoV5-1 and 32CrMoV12-28 hot work tool steels with carbide powders as well as results of laser

For this reason, an analysis has been carried out in the subject research work on an implant’s surface roughness impact and a steam sterilization process impact on

The adhesive performance was in line with the apparent contact angle measurement results and was higher at the samples with higher surface roughness but just

Purpose: In this work there are presented the investigation results of mechanical properties and microstructure concerning mainly intermetallic phases of the aluminium – titanium

Hardness and electrical conductivity changes versus ageing time at temperature of 500 o C (in which the highest hardness and electrical conductivity values

For such samples, surface topography was examined and roughness parameters such as R a (arithmetic means deviation of profile ordinates from the mean line),R z (average roughness

The commonly used carburizers were selected for the experiments (anthracite, natural and synthetic graphite, petroleum coke of various grades), cupola coke and