KSUPS 2015: Abstracts / Extended abstracts / Synchrotron Radiation in Natural Science Vol. 14, No. 1-2 (2015)

32 O-11 Thu. 03. 09., 1020-1040

Micro-X-Ray fluorescence spectrometer with X-ray single bounce metallic capillary optics for light element analysis

R. Mroczka1*, A. Sykuła1, E. A.Stefaniak1,2

1 Laboratory of X-ray Optics, Centre for Interdisciplinary Research, The John Paul II Catholic University of Lublin, Konstantynów 1, 20-708 Lublin, Poland,

2 Department of Chemistry, The John Paul II Catholic University of Lublin, Konstantynów 1, 20-708 Lublin, Poland,

Keywords: micro-XRF spectrometer, X-ray metallic capillary optics, light elements analysis

*e-mail: rmroczka@kul.pl

In the last 20 years, due to the rapid development of X-ray optics, micro X-ray fluorescence spectrometry (micro-XRF) has become a powerful tool to determine the spatial distribution of major, minor, and trace ele- ments within a sample.

Micro-X-ray fluorescence (micro-XRF) spectrome- ters for light element analysis (6 ≤ Z ≤ 14) using glass polycapillary optics are usually designed and applied to confocal geometry. Two such X-ray optics systems are used in this setup. The first one focuses the primary beam on the sample; the second restricts the field of view of the detector. In order to be able to analyze a wider range of elements especialy with (6 ≤ Z ≤ 14), both sample and detector are under vacuum. Depth resolution varies be- tween 100 μm at 1 keV fluorescence energy (Na-Kα) and 30 μm for 17.5 keV (Mo-Kα) [1,2].

In order to improve resolution at energies below 9 keV, our group designed similar spectrometer (in coop-

eration with PREVAC) but instead of primary polycapil- lary optics we applied single bounce metallic capillaries optics, designed and manufactured in our Laboratory.

The vacuum chumber is currently under construction and is expected to be fully operational in September this year.

Single bounce gold capillaries with elliptic internal shape have recently been redesigned and developed in our Laboratory. Surface roughness was reduced up to 0.5 nm and slope error to 0.3 mrad. For these capillaries an expected depth resolution varies from 3 µm (1 keV) and 10 µm for 9 keV (Cu-Kα).

The spectrometer equipped with gold capillaries of- fers the possibility of elemental analysis with better depth resolution than is offerred by glass polycapillaries at energies below 9 keV.

To further extend analytical capabilities of single bounce metallic capillaries, we will present a design of a micro-XRF spectrometer using synchrotron radiation (SR). Capillaries with parabolic shape will be applied in order to focus SR. This proposal can be considered as a part of our Polish Synchrotron SOLARIS.

Furthermore, we will compare the capabilities and limitations of this spectrometer with others, that use laboratory and/or synchrotron sources.

Acknowledgments: This work was supported and co-funded by the European Union as part of the Operational Programme Development of Eastern Poland for 2007–2013, Priority I Innovative Economy, Measure I.3. Support for Innovations and The National Centre for Research and Development, Project no.

TANGO1,267102/NCBR/2015.

________________________________________________

[1] S. Smolek, B.Pemmer, M. Folser, C. Streli, P. Wobrauschek, Review of Scientific Instruments 83 (2012) 083703.

[2] S. Smolek , T. Nakazawa, A. Tabe, K. Nakano, K. Tsuji, C. Streli , P. Wobrauschek, X-ray Spectrometry 43 (2014) 93.

Cytaty

Powiązane dokumenty

Particle Induced X-ray Emission (PIXE) enables quantitative element-specific analysis based on characteristic K and L x-rays emitted from the sample after excitation by MeV He+ or

In anisotropic media, ei- ther uniaxial or biaxial, the Poynting and wave vectors are not parallel in general, since the electric field vector E and the electric flux density vector

Figure 3 shows the temporal behavior of the XL/ afterglow intensity of undoped and Eu-doped barium halides after switching on 共for 5 min兲 and off the x-ray excitation at RT;

In contrast to BaCl 2 and BaBr 2 , the x-ray scintillation efficiency for 0.1% Ce-doped BaI 2 is smaller than the corre- sponding ␥ -ray light yield value obtained from pulse

3 Institute of Chemistry, Jan Kochanowski University, ´ Swi¸ etokrzyska 15, 25–406 Kielce, Poland Keywords: X-ray fluorescence, X-ray powder diffraction, halloysite samples.. ∗ e-mail

5 Physics Department, National University of Singapore, 2 Science Drive 3, 117542 Singapore Keywords: synchrotron radiation, XRF, fluorescence spectroscopy, R platform,

X-ray absorption anisotropy (XAA) recorded using a white synchrotron beam contains an unique information about local atomic structure.. For a crystal, fine-structures in

It is therefore essential to gather now the potential Polish scientific users of the European XFEL and work jointly towards successful beamtime proposals and