• Nie Znaleziono Wyników

Intracoronary adenosine-induced torsades de pointes during fractional flow reserve measurement

N/A
N/A
Protected

Academic year: 2022

Share "Intracoronary adenosine-induced torsades de pointes during fractional flow reserve measurement"

Copied!
2
0
0

Pełen tekst

(1)

Address for correspondence: Sophie Degrauwe, MD, Department of Cardiology, Hôpitaux Universitaires Genève, Rue Gabrielle-Perret-Gentil 4, 1205 Genève, Switzerland, tel: +41 79 553 02 94, fax: +41 22 372 72 29, e-mail: sophie.degrauwe@hcuge.ch

Received: 13.05.20199 Accepted: 19.08.2019

Intracoronary adenosine-induced torsades de pointes during

fractional flow reserve measurement

Sophie Degrauwe

1

, Alessia Azzano

2

, Juan F. Iglesias

1

, Carlo Zivelonghi

2

, Stefan Verheye

2

, Carl Convens

2

, Paul Vermeersch

2

, Benjamin Scott

2

1Department of Cardiology, Geneva University Hospital, Geneva, Switzerland

2Department of Cardiology, ZNA Middelheim, Antwerp, Belgium

We report a 58-year-old woman with multiple cardiovascular risk factors presenting with stable angina. Echocardiography demonstrated normal systolic left ventricular function (ejection fraction 65%), with the absence of structural abnormalities.

The patient was referred for coronary angiography, demonstrating angiographic intermediate stenosis in the proximal segment of the intermediate artery (IA) and left anterior descending artery (LAD) (Fig. 1).

Fractional flow reserve (FFR) measurement using adenosine (240 µg, volume 20 mL) was performed in the IA as well as LAD, both measures were nega- tive, respectively 0.97 and 0.84 (Fig. 2). Following immediate intracoronary (IC) adenosine adminis- tration in the LAD the patient developed torsades de pointes (TdP) with circulatory collapse (Fig. 2).

Intra-procedural electrocardiogram revealed su- praventricular extra-systoles with short coupling

Figure 1. Coronary angiogram demonstrating angiographic intermediate stenosis of the proximal left anterior descending artery.

INTERVENTIONAL CARDIOLOGY

Cardiology Journal 2019, Vol. 26, No. 5, 612–613

DOI: 10.5603/CJ.2019.0103 Copyright © 2019 Via Medica

ISSN 1897–5593

612 www.cardiologyjournal.org

IMAGE IN CARDIOVASCULAR MEDICINE

(2)

Figure 3. Electrocardiogram and arterial pressure following immediate intra-coronary adenosine administration for fractional flow reserve measurement of the left anterior descending artery, leading to torsades de pointes, with spon- taneous self-termination.

Figure 2. Fractional flow reserve (FFR) console screenshot demonstrating FFR values measured in the intermediate artery (0.97) and left anterior descending artery (0.84).

at the time of adenosine injection, preceding the onset of TdP (Fig. 3).

Recognized adenosine-induced ventricular ar- rhythmias (VA) include (1) ventricular fibrillation (VF) in pre-excited atrial fibrillation, (2) polymorphic ventricular tachycardia (VT) in long Q-T syndromes, (3) degeneration of VT to VF and (4) non-sustained VT following termination of supraventricular tachy- cardia. VA induced by adenosine for FFR assess- ment is a rare complication described in 5 cases in available literature, occurring after adenosine administration in patients with FFR positive and negative lesions, suggesting a lack of causality between myocardial ischemia and the onset of VA.

The mechanisms of VA induced by IC adenosine

administration might be related to adenosine dose and concentration, saline bolus injection volume, or pharmacological effect of adenosine (induces VF by “R on T” phenomenon with or without atrioventricular block). This is the first description of IC adenosine induced TdP with circulatory col- lapse. The mechanism seems to be at least partially linked to adenosine induced enhanced ventricular automaticity. FFR is currently considered the gold standard for the functional assessment of coronary stenosis; however, its measurement warrants the need of adenosine. The present case highlights that caution is of the essence when performing adeno- sine injection for an FFR measurement in a patient presenting extrasystoles with short coupling.

Conflict of interest: None declared

www.cardiologyjournal.org 613

Sophie Degrauwe et al., Intracoronary adenosine-induced torsades de pointes during FFR measurement

Cytaty

Powiązane dokumenty

METHODS We enrolled consecutive patients with borderline coronary lesions that were assessed by FFR with the use of intracoronary adenosine bolus (100 µg, 200 µg, 400 µg, and 600

Minimisation of the risk of errors (which can result in significant signal drift > 3 mmHg and reclassification of even ~18% of FFR measurements) includes, among others,

Results: The mean height from coronary ostium to distal left anterior descending (LAD) was +5.26 cm, distal circumflex (Cx) –3.35 cm, distal right coronary artery-posterior

The present study received grants from the National Key R&D Program of China (2017YFC0910004 and 2017YFB0702500), the National Natural Science Foundation of China (grant

The key messages of this study can be sum- marised as follows: 1) predicted FFR for each lesion in sequential coronary stenosis can be accurately calculated by a novel

RXi microcatheters allow the FFR measurement after revascularization using the same wire which was used during stent implantation, eliminating the need to re- cross the

Following administration of intra-coronary adenosine for fractional flow reserve (FFR) assessment, the patient developed atrial fibrillation (AF).. While well de- scribed

Fractional flow reserve (FFR) is an index of the physiological significance of a coronary stenosis, and is defined as the ratio of maximal blood flow in a stenotic artery to