Usefulness of CorMatrix-based tricuspid valve repair in the treatment of infective endocarditis

N/A
N/A
Protected

Academic year: 2022

Share "Usefulness of CorMatrix-based tricuspid valve repair in the treatment of infective endocarditis"

Copied!
1
0
0

Pełen tekst

(1)

www.kardiologiapolska.pl

Kardiologia Polska 2018; 76, 2: 476; DOI: 10.5603/KP.2018.0047 ISSN 0022–9032

STUDIUM PRZYPADKU / CLINICAL VIGNETTE

Address for correspondence:

Paweł S. Czub, MD, Department of Cardiac Surgery, Medical University of Warsaw, SPCSK, ul. Banacha 1A, 02–097 Warszawa, Poland, e-mail: pczub73@gmail.com Conflict of interest: none declared

Special acknowledgment to our mentor Professor Romuald Cichoń and colleagues: Anna Słowikowska, Radosław Wilimski, and Zbigniew Popiel.

Kardiologia Polska Copyright © Polskie Towarzystwo Kardiologiczne 2018

Usefulness of CorMatrix-based tricuspid valve repair in the treatment of infective endocarditis

Zastosowanie macierzy CorMatrix w leczeniu infekcyjnego zapalenia wsierdzia z zajęciem zastawki trójdzielnej

Paweł S. Czub

1

, Adam Arendarczyk

1

, Marek Kopala

2

, Monika Budnik

3

, Piotr Hendzel

1

1Department of Cardiac Surgery, Medical University of Warsaw, Warsaw, Poland

2Cardiac Surgery Department, Polish Mother’s Health Centre — Research institute, Warsaw, Poland

31st Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland

A 34-year-old man addicted to heroin and mephedrone was transported to the cardiac surgery unit from the Isolation Hospital due to infective endocarditis (IE) of the tricuspid valve (TV) with severe regurgitation. Blood cultures indicated an increase in Staphylococcus aureus MSSA — a targeted antibiotic treatment with cloxacillin 6 × 2 g IV was added. The echocardiography revealed a large vegetation on the anterior leaflet of the TV, 31 × 20 mm in size, right atrium enlargement, and severe TV regurgitation (Fig. 1). Until recently, the only treatment options for IE causing significant damage to the TV were replacement of the valve with a biological or mechanical implant or advanced valvuloplasty. These methods, however, carry a risk of reinfection, dysfunction of the artificial prosthesis, as well as the potential complications inherent to aggressive treatment with vitamin K antagonists (VKA). Employing a CorMatrix patch may present an alternative method for treating IE. CorMatrix is an extracted extracellular matrix to which growth factors, matricellular proteins, glycosaminoglycans, and adhesion factors were applied. After implantation into human tissue, CorMatrix functions as a scaffold onto which the body’s own cells migrate, depending on the location of the implant. The material also promotes the migration of leukocytes — a crucial property when treating IE because it prevents further reinfection. Before opening the patient’s chest, the surgeon crafts a tubular CorMatrix patch, using the dimensions of the TV established during the pre-surgery cardiac echo as a template (the tricuspid annular diameter and the distance from the annulus to the papillary muscles in diastole). After sternotomy and removing the native TV, the surgeon implants the newly crafted valve to the native annulus and the papillary muscles. A CorMatrix-reconstructed TV (15 × 7 cm patch) was implanted.

The intraoperative transoesophageal echocardiogram indicated the proper functioning of the CorMatrix prosthesis with only an insig- nificant regurgitation (Fig. 2). The patient was discharged from the intensive care unit two days after the surgery. During the following days, a gradual normalisation of biochemical parameters was observed. In good overall condition, the patient was transferred to the Isolation Hospital to continue intravenous antibiotic treatment. Six months after the surgery, a follow-up cardiac echo showed no tricuspid regurgitation and no reinfection. Until now, IE of the TV carried a high risk of reinfection. Additionally, there are no valves dedicated specifically to the tricuspid configuration available. The long-term outcomes of the implantation of a CorMatrix valve shed a new light on the treatment of IE of the TV. An additional advantage of the method is that it does not require any anticoagulant treatment with all abbreviation should be spelled out VKA, which often has a great impact on the quality of life of young patients.

Figure 1. A. Two-dimensional echocardiography; B. Three-dimensio- nal echocardiography; C, D. Intraoperative view. The arrows show the bacterial vegetation on the anterior leaflet of the tricuspid valve

A B

C D Figure 2. A. Two-dimensional transthoracic echocardiography;

B. Two-dimensional transoesophageal echocardiography;

C. CorMatrix patch; D. Intraoperative view

A B

C D

Cytaty

Powiązane dokumenty

Only 1 report of a patient with fungal tricuspid endocarditis (Candida parapsi- losis) 2 years after abdominal surgery was found in the literature.

During the first hospitalisation transthoracic echocardiography (TTE) revealed a round mobile echogenic mass attached to the arterial side of the pulmonary valve, without

According to the current European Society of Cardiology (ESC) guidelines for the management of valvular heart disease, a percutaneous edge-to-edge procedure may be considered

A 67-year-old patient after DDD pacemaker implantation due to complete atrioventricular block (17.04.2014), dislocated right atrial lead (RAL) reposition and pacemaker

Five months prior to admission the patient underwent tricuspid valve replacement with a 31-mm Edwards Lifesciences bioprosthesis due to staphylococcal endocarditis and severe

Po udarze mózgu należy rozważyć leczenie operacyjne bez opóźnienia w przypadku wskazań w postaci niewydolności serca, niekontrolowanego zakażenia, ropnia lub utrzymującego się

Tissue fragments encapsulating endocardial lead body except the vegetation were mainly connective tissue with partial hyalinisation, with features of vasculogenesis (Fig.. Fragments

W kontrolnej TEE wykonanej po 3 tygodniach utrzymywała się opisywana struktura na brzegu przedniego płatka zastawki mitralnej i na ciągłości mitroaortalnej (bez mian na