Kardiologia Polska 2016; 74, 4: 393; DOI: 10.5603/KP.2016.0050 ISSN 0022–9032

STUDIUM PRZYPADKU / CLINICAL VIGNETTE

Address for correspondence:

Prof. Marko Noc, Centre for Intensive Internal Medicine, University Medical Centre, Zaloska 7, 1000 Ljubljana, Slovenia, e-mail: marko.noc@mf.uni-lj.si Conflict of interest: none declared

Kardiologia Polska Copyright © Polskie Towarzystwo Kardiologiczne 2016

Veno-arterial extracorporeal membrane oxygenation and embolectomy in massive pulmonary thromboembolism

Tętniczo-żylne pozaustrojowe utlenowanie krwi i embolektomia w masywnej zatorowości płucnej

Jus Ksela

1

, Rihard Knafelj

2

, Maja Sostaric

1

, Marko Noc

1

1Department of Cardiovascular Surgery, University Medical Centre, Ljubljana, Slovenia

2Centre for Intensive Internal Medicine, University Medical Centre, Ljubljana, Slovenia

A 44-year-old man with varicose syndrome presented after collapse followed by refractory cardiac arrest. Advanced cardiac life support was started, and due to suspected massive pulmonary thromboembolism, intravenous recombinant tissue plasminogen activator — rt-PA (Actylise, Boehringer Ingelheim, Germany) was administered. After 40 min of resuscita- tion, spontaneous circulation was re-established, but profound circulatory shock with recurrent cardiac arrests persisted.

The patient was transferred to catheterisation laboratory for percutaneous implantation of veno-arterial extracorporeal membrane oxygenation (VA ECMO) (Cardiohelp, Maquet Getinge group). A 21 Fr short cannula was inserted through the right femoral artery with the tip at the aortic bifurcation, an 8 Fr 11 cm anterograde sheath for ipsilateral limb perfusion, and a 25 Fr long venous cannula through the right femoral vein with the tip at the right atrium. With 3.5 L/min of ECMO flow, haemodynamic stabilisation was achieved and the patient was immediately transferred for pulmonary computed tomography angiography, which showed that except for the right upper segment, pulmonary circulation was essentially obstructed (Fig. 1A). Immediate surgical embolectomy was performed and two large thrombotic columns were removed from the left and right pulmonary arteries (Fig. 1B). The postoperative course was unremarkable and the patient was discharged without any neurological sequel despite more than 40 min of refractory cardiac arrest.

Figure 1. Pulmonary computed tomography angiography showing complete obstruction of left side and large part of right side of pulmonary circulation (A, arrows). Corresponding thrombotic columns were removed by immediate surgical embo- lectomy from left and right pulmonary arteries (B)

A B

Cytaty

Powiązane dokumenty

While standard images gave precise characterization of the stenosis, three-dimensional reconstruction images accurately visualized multiple stenosis, highlighting the anatomy of

[8] in EOLIA trial stated that the analysis of the primary end point (mortality at 60 days) in their trial involving patients with very severe acute respiratory distress syndrome

Demographic, clinical, and haemodynamic data at the time of lung HRCT for the whole study group and for subgroups depending on the HRCT findings are shown in table 1. There were

compartment syndrome, as was the case with our patient, but usually it is a severe and late complication. There are multiple reasons for the development of hyperperfusion syndrome

Intermediate– –high-risk PELMWH, vasopressors followed by CDT Absolute contraindica-tions to thrombolysisPrimary CDT: Unilateral + balloon angioplasty with peripheral catheter 6.0

A 63-year-old patient, with a body mass index (BMI) of 29 kg/m 2 , clinically unstable, with massive pulmonary embolism caused by deep vein thrombosis, was transferred to the

Background: Patients suffering from cardiogenic shock, with no response to conventional therapy, may significantly improve when put on support devices such as extracorporeal

Transthoracic echocardiography (TTE) revealed no embolism in the heart ventricles and no changes in right ventricular function. 6 days on from the first admission), the