• Nie Znaleziono Wyników

Nanotubularne warstwy tlenkowe na stopie Ti6Al4V jako matryce elektrochemicznego biosensora; Nanotubular oxide layer on the Ti6Al4V alloy as a matrix for electrochemical biosensor - Digital Library of the Silesian University of Technology

N/A
N/A
Protected

Academic year: 2021

Share "Nanotubularne warstwy tlenkowe na stopie Ti6Al4V jako matryce elektrochemicznego biosensora; Nanotubular oxide layer on the Ti6Al4V alloy as a matrix for electrochemical biosensor - Digital Library of the Silesian University of Technology"

Copied!
2
0
0

Pełen tekst

(1)

POLITECHNIKA ŚLĄSKA W GLIWICACH

Wydział Mechaniczny Technologiczny

mgr inż. Agnieszka Kaczmarek

ROZPRAWA DOKTORSKA

Nanotubularne warstwy tlenkowe na stopie Ti6Al4V jako matryce

elektrochemicznego biosensora

Promotor:

Dr hab. inż. Elżbieta Krasicka- Cydzik, prof. UZ

(2)

Abstract

Nanotubular oxide layer on the Ti6Al4V alloy as a matrix for electrochemical biosensor

The work presents a novel application of anodically formed nanotubular oxide layer on the Ti6Al4V alloy. The results confirm that this nanotubular oxide layer, made of vanadium, titanium and aluminum oxides enables quick and reliable electrochemical detection of bone alkaline phosphatase within 1-10 ng/ml concentration. To prepare the biosensor electrode based on the Ti6Al4V alloy, the optimalization of anodizing process, and the explanation of the influence of electrolyte composition on nanotubular oxide layer morphology, was required. Uniform nanotubular oxide layer with nanotubes of 50 nm diameter and 1µm thickness on the Ti6Al4V alloy was obtained in ethylene glycol electrolyte with 1% wt. of H2O and 0.6% wt. NH4F by anodizing at 22V for 20 min. To increase

electrical conductivity of nanotubular oxide layer containing TiO2, Al2O3, VO2 and V2O5,

the thermal modification was carried out at 600 ̊C for 2 h in argon, nitrogen or air. Vanadium diffusion through nanotubular oxides upon both phases was observed during heating in nitrogen. The SEM, EDS, XRD, XPS and electrochemical tests of nanotube layers in PBS solution confirmed their unique electrical properties. The nanotubular oxide layer on the Ti6Al4V alloy with 50nm diameter and 1µm thickness after thermal modification in nitrogen and functionalization by bALP antibody revealed to be suitable for the amperometric and impedimetric detection of bALP antigen.

Cytaty

Powiązane dokumenty

Obliczenie prawdopodobie stwa powstawania warstwy kompozytowej o okre lonej grubo ci dla zało onych parametrów technologicznych i materiałów preformy.. Zało enia

focused on mechanical wear, which can be divided into the subcate- gories of abrasive wear and strength (emergency or fatigue) wear. Several tool tooth wear criteria can

This paper presents a multi-factorial approach to the tool wear evolution when machining Ti6Al4V titanium alloy using high temperature resistant AlTiN coated cutting tools..

For such samples, surface topography was examined and roughness parameters such as R a (arithmetic means deviation of profile ordinates from the mean line),R z (average roughness

The best process deposition parameters for the tested composite chitosan–nanosilver coating, the nanotubular oxide layer, and the Ti13Zr13Nb alloy as a substrate, used as

For this reason, an analysis has been carried out in the subject research work on an implant’s surface roughness impact and a steam sterilization process impact on

On the ground of the performed test it can be proved that the process of application of TiO 2 layer by means of sol-gel method performed in order to ensure proper procedures

Wprawdzie współczesne metody symulacji komputerowej umożliwiają szybkie i bardzo dokładne obliczenia błędu bez potrzeby uciekania się do jakichkolwiek przybliżeń,