Cardiology Journal 2020, Vol. 27, No. 4, 376–383 DOI: 10.5603/CJ.a2018.0118 Copyright © 2020 Via Medica

ISSN 1897–5593

ORIGINAL ARTICLE

High-sensitive troponin T increase after hemodialysis is associated with left ventricular global longitudinal strain and ultrafiltration rate

Serkan Ünlü1, 2, 3, Asife Şahinarslan1, Burak Sezenöz1,Orhan Mecit Uludağ3, Gökhan Gökalp1, Özden Seçkin1, Selim Turgay Arınsoy4,

Özlem Gülbahar5, Nuri Bülent Boyacı1

1Department of Cardiology, Faculty of Medicine, Gazi University, Ankara, Turkey

2Department of Cardiology, Atatürk Chest Diseases and Chest Surgery Education and Research Hospital, Ankara, Turkey

3Department of Pharmacology, Faculty of Pharmacy, Gazi University, Ankara, Turkey

4Department of Nephrology, Faculty of Medicine, Gazi University, Ankara, Turkey

5Department of Medical Biochemistry, Faculty of Medicine, Gazi University, Ankara, Turkey

Abstract

Background: Circulating troponin levels are both stable and higher in patients with end-stage renal disease, even in the absence of acute coronary syndrome. These patients commonly have underlying cardiac problems that frequently cause troponin elevation. The effect of hemodialysis (HD) on troponin levels has not been well elucidated. Thus, investigated herein is the relationship between the changes in troponin levels along with left ventricular deformation and volume depletion in patients with end-stage renal disease.

Methods: Patients included were between 18 and 85 years of age and were receiving hemodialysis for at least 6 months. High sensitive cardiac troponin T (hs-cTnT) levels were studied in blood samples taken at the beginning and end of HD. Two-dimensional speckle tracking strain imaging was used to evaluate myocardial contractility.

Results: Seventy patients (50.7 ± 16.9 years of age, 27 women) were included in study. The mean volume of ultrafiltration was 3260 ± 990 mL. A significant increase in circulating hs-cTnT levels was observed, as well as a prominent decrease in left ventricular global longitudinal strain (GLS) after HD (52.4 ± 40.2 ng/L vs. 66.8 ± 48.5 ng/L, p < 0.001 and 20.1 ± 3.6% vs. 16.8 ± 3.8% p < 0.001, respectively). Moreover, ultrafiltration rate and GLS were found as the strongest independent variables in relation to the relative increase in hs-cTnT.

Conclusions: Hemodialysis can cause a significant increase in hsTnT. This can jeopardize the accu- racy of clinical diagnoses based on hs-TnT measurements. GLS may be used as a determinant of this hs-TnT increase. The influence of HD on the cardiovascular system should be kept in mind to prevent unnecessary interventions. (Cardiol J 2020; 27, 4: 376–383)

Key words: dialysis, high-sensitive, load, speckle, troponin

Introduction

Troponins (Tn) are structural proteins in- volved in the regulation of skeletal and cardiac

muscle contractility and cardiac troponins (cTn) are being used as sensitive and specific markers of cardiac injury [1]. Recently developed, new gen- eration, high-sensitive cardiac troponin (hs-cTn)

(2)

assays [2, 3] made it possible to detect cTn levels in lower concentrations and provided faster diag- nostic information, which resulted in a reduced duration of patient hospitalization [4]. However, a variety of conditions can cause an increase in hs- cTn in the absence of ischemic heart disease [1], one of these conditions being, patients with end- stage kidney disease who were shown to have higher circulating Tn levels compared to the normal population [5–12]. In these patients, un- derlying cardiac problems that frequently lead to cTn elevation are also common. However, the relationship between renal function disorders and the cTn increment is still not fully understood. The effect of dialysis on cTn levels has also not been robustly elucidated. Long-term cTn measurements in patients receiving dialysis therapy were shown to be higher than reference values without acute exacerbations [7, 8, 12, 13]. There are, however, few studies examining the acute effect of dialysis on cTn levels. Moreover, end-stage renal disease increases the likelihood of having concomitant heart disease and structural abnormalities such as left ventricular (LV) hypertrophy which also causes electrocardiographic findings that mimic ischemia.

Thus, clinicians are obliged to depend on Tn meas- urements to diagnose acute coronary syndromes.

In addition, higher ultrafiltration volumes may result in myocardial stunning [14–16] and show an impact on cTn levels. LV global longitudinal strain (GLS) — a marker of LV systolic function

— is associated with poor prognosis and has been suggested to be a better prognostic indicator than conventional LV ejection fraction (EF) in patients with chronic kidney disease [17, 18]. Therefore, the present study was to investigate (i) the change in circulating hs-cTnT levels with hemodialysis (HD);

(ii) the relationship between changes in hs-cTnT levels and volume depletion and (iii) changes in LV deformation as assessed by two-dimensional (2D) strain echocardiography with HD.

Methods Study population

This study had a cohort of 70 patients, who were followed up in the Hemodialysis Unit of Gazi University Medical School Nephrology Depart- ment. Patients between 18 and 85 years of age, who were receiving systemic bicarbonate HD 3 times a week for at least 6 months were included.

Patients with LV systolic dysfunction (< 53%) [19], evident coronary artery disease and moderate to

severe valvular heart disease, atrial fibrillation, acute coronary syndrome, infectious and inflam- matory conditions and pulmonary embolism were excluded from the study. This study was approved by the local ethical committee.

Study protocol

Blood samples and echocardiographic acqui- sitions were obtained by providing 72 h between HD sessions in order to achieve higher volume changes. Dry weight is targeted for each patient during HD sessions. Blood pressure, weight and heart rate were measured before and after HD.

The ultrafiltration volume and rate were recorded.

Blood samples

Blood samples were collected immediately before and after HD. HsTnT levels were measured with a high sensitive troponin assay (Elecsys® Troponin T hs, Roche Diagnostics) with lower de- tection and upper reference (99th percentile) limits of 3 ng/L and 14 ng/L, respectively.

Echocardiography

All images were acquired and measurements were performed by an experienced sonographer (SÜ) with a GE Vivid 7 Dimension ultrasonogra- phy machine (GE Vingmed Ultrasound, Horten, Norway) equipped with a 3.5 MHz transducer, immediately before and after HD. Electrocardio- gram and respiration of patients were monitored.

Echocardiographic images with at least three cardiac cycles were recorded at the end of expira- tion. The images were then transferred to a ven- dor-specific workstation and analysed with EchoPAC, BT 13 (GE Vingmed Ultrasound, Hort- en, Norway) software. All echocardiographic meas- urements were performed according to recent guidelines [19].

LV strain and strain rate analysis

Apical 4-, 3-, 2-chamber views were acquired with high frame rate (> 60 fps) for 2D speckle tracking strain analysis. To define the region of interest, the endocardial surface was identified by manually placing at least 15 markings in all apical views. End-diastole was indicated by the peak of the R-wave on the electrocardiogram.

Average GLS were measured as the mean of GLS from 4-, 3-, 2-chamber apical views. All strain and echocardiographic measurements were performed by SÜ, who has a long experience with deforma- tion imaging.

(3)

Statistical analysis

Continuous variables are presented as mean

± standard deviation and categorical data are presented as percentages or frequencies. Kolmog- orov-Smirnov was used to check for normality of distribution for continuous variables. The paired t-test and Wilcoxon test were used to compare parametric and nonparametric continuous vari- ables, respectively, before and after HD. Categori- cal variables were compared by the c2 test. The Pearson correlation test was used to evaluate the relationship among changes in hs-cTnT levels, GLS and fluid volume withdrawal. Univariate lin- ear regression analysis with conventional clinical variables (age, gender etc.) and contributors with a significant correlation were entered in a multi- ple linear regression model. Possible collinearity was checked by using a tolerance and variance inflation factor. Variables with a tolerance of less than 0.10 and a variance inflation factor of 10 and above were withdrawn from the multivariate linear regression model. A two-tailed p-value of < 0.05 was considered as statistically significant. All data were analysed with SPSS v.23.0.

Results

Among 80 patients screened, 70 of them were included in this study. Seven patients were excluded because of newly diagnosed LV systolic dysfunction, it was not possible to collect blood samples after HD in 3 patients. The baseline char- acteristics of participants are presented in Table 1.

A decrease in both systolic and diastolic blood pressures and an increase in heart rate after HD was observed. However, no significant tachycardia (> 100 bpm) was detected after HD, except in 3 patients. The mean volume of ultrafiltration was 3260 ± 990 mL. Comparison of clinical vital signs before and after HD is shown in Table 2.

A significant increase in serum hs-cTnT levels after HD was observed (52.4 ± 40.2 ng/L vs. 66.8 ±

± 48.5 ng/L, p < 0.001; Fig. 1). A relative change in hs-cTnT and ultrafiltration rate showed a sig- nificant correlation (Fig. 2).

The size of LV and left atrium decreased after HD, whereas LV EF remained unchanged.

LV GLS also notably decreased after HD. Data of echocardiographic parameters are listed in Table 3.

The relative change in GLS showed strong correla- tions with relative change in hs-cTnT (Fig. 3) and ultrafiltrated volume (Fig. 4).

In a linear regression analyses, relative change in GLS, ultrafiltration rate ultrafiltrated volume, and relative change in heart rate were significantly correlated with the relative change in hs-cTnT. Ul- trafiltrated volume was removed from multivariate analysis since a high collinearity was found with ultrafiltration rate. Multivariate linear regression analysis revealed that the ultrafiltration rate and the relative change of LV GLS were the strongest independent variables associated with an increase in hs-cTnT levels (Table 4).

Discussion

In this study, the acute impact of HD on hs- cTnT levels were investigated. The main findings can be summarized as follows: (i) hs-cTnT levels

Table 1. Baseline characteristics of the participants.

Parameters Mean/Frequency

(n = 81)

Age [year] 50.7 ± 16.9

Gender (male) 43 (61.4%)

BMI [kg/m2] 23.5 ± 4.4

Duration of HD [month] 78.2 ± 58.7 Ultra-filtrated volume [mL] 3260 ± 990 Ultrafiltration rate [mL/kg/h] 11.6 ± 3.0

Hypertension 27 (33.3%)

Hyperlipidemia 24 (29.6%)

Diabetes mellitus 14 (17.2%)

Glomerulonephritis 10 (12.3%)

Other 13 (16.1%)

Primary unknown renal failure 7 (8.6%)

BMI — body mass index; HD — hemodialysis; Other — polycystic kidney disease, amyloidosis, nephrolithiasis, vesicoureteral reflux, pyelonephritis, autoimmune diseases, toxic nephropathy

Table 2. Vital clinical parameters before and after hemodialysis (HD).

Parameters Before HD After HD P

Systolic blood pressure [mmHg] 123.3 ± 21.7 104.2 ± 21.6 < 0.001

Diastolic blood pressure [mmHg] 74.4 ± 12.9 62.6 ± 13.1 < 0.001

Heart rate [bpm] 78 ± 15 86 ± 16 < 0.001

Weight [kg] 70.4 ± 17.6 66.6 ± 15.2 < 0.001

(4)

Table 3. Echocardiographic measurements before and after hemodialysis (HD).

Parameters Before HD After HD P

Dimensions. areas and volumes of left heart

LV end-diastolic diameter (cm) 4.4 ± 0.7 4.0 ± 0.8 < 0.001

LV end-diastolic volume (ml) 75.3 ± 22.7 68.5 ± 29.7 < 0.001

LV end-systolic volume [mL] 26 ± 11.2 23.8 ± 17.8 0.401

LV ejection fraction [%] 66.0 ± 11.5 64.2± 10.6 0.071

LA diameter [cm] 5.1 ± 1.4 4.7± 1.4 < 0.001

LA area [cm2] 29.9± 10.6 19.9 ± 10.3 < 0.001

LA volume index [mL/m2] 48.7 ± 16.3 33.4 ± 16.1 < 0.001

Doppler measurements of left ventricle

E [cm/s] 99 ± 24.8 65.5 ± 23.1 < 0.001

A [cm/s] 94 ± 92.1 76.7 ± 26.9 < 0.001

E/A 1.18 ± 0.6 0.92 ± 0.34 < 0.001

Tissue Doppler measurements of left ventricle

E’lateral [cm/s] 11.1 ± 2.8 10.1 ± 2.8 0.001

A’lateral [cm/s] 12.5 ± 4.1 10.2 ± 3.4 < 0.001

S’lateral [cm/s] 11.1 ± 10.2 9.6 ± 2.9 < 0.001

E/E’lateral 8.8 ± 3.8 6.3 ± 2.9 < 0.001

E’septal [cm/s] 10.9 ± 2.5 10.1 ± 2.8 0.001

A’septal [cm/s] 8.8 ± 2 7.9 ± 2.4 < 0.001

S’septal [cm/s] 10 ± 3.6 8 ± 2.6 < 0.001

E/E’septal 9.6 ± 3.7 8.0 ± 2.4 < 0.001

Speckle tracking echocardiography

LV GLS [%] –20.1 ± 3.6 –16.8 ± 3.8 < 0.001

GLS — global longitudinal strain; LA — left atrium; LV — left ventricle

Figure 1. High-sensitive cardiac troponin T (hs-cTnT) levels before and after hemodialysis (HD). Comparison between mean values before and after HD is presented.

Significance is indicated on the graph.

Figure 2. Comparison between relative change of high- sensitive cardiac troponin T (hs-cTnT) (y-axis) and the ultrafiltration rate (x-axis). The correlation coefficient (R) is indicated. P value is < 0.001.

–40 –20 0

0 5 10 15 20 25

20 40 60 80 100 120

Ultafiltration rate [mL/kg/h]

Relative change in hs-cTnT [%]

R = 0.80

(5)

show a statistically significant increase after HD, (ii) relative change in hs-cTnT levels shows strong correlation with ultrafiltration rate, (iii) LV systolic function evaluated by 2D speckle tracking analysis deteriorates with high rapid volume depletion, (iv) the relative change in GLS and ultrafiltration rate are independently associated with a relative hs- cTnT increase after HD.

Selection of study population

There have been several studies which aimed to investigate the impact of HD on cTn levels [7, 8, 10–13, 20–23]. According to available re- search, none of the studies evaluated the relation of ultrafıltration rate, deformation indices and

changes in circulating cTn levels. Therefore, it was decided to investigate patients with end-stage kidney disease at a time when the highest volume change can be achieved. By having 3200 mL of average ultrafiltration volume, it was believed that this would obtain the highest possible volume changes in the literature. In addition, patients without significant cardiac diseases, except LV hypertrophy, were enrolled to avoid possible effects of cardiac pathologies on changes in cTn levels.

Changes in vital signs and cardiac function with HD

In the present study, both systolic and dias- tolic blood pressures decreased after HD, which is

Figure 3. Comparison between relative change of global longitudinal strain (GLS) measurements (y-axis) and rela- tive change in high-sensitive cardiac troponin T (hs-cTnT) (x-axis). The correlation coefficient (R) is indicated.

P value is < 0.001.

0–50 0 50 100 150

20 10 30 40

50 R = 0.70

Relative change in hs-cTnT [%]

Relative change in GLS [%]

Figure 4. Comparison between relative change of global longitudinal strain (GLS) measurements (y-axis) and the ultrafiltrated volume (x-axis). The correlation coefficient (R) is indicated. P value is < 0.001.

Table 4. Determinants of relative increase in high sensitive troponin T levels after hemodialysis.

Parameters Univariate Multivariate

r p R2 p

Age [year] –0.200 0.159

0.826

Gender –0.187 0.282

Change in systolic BP 0.386 0.10

Change in diastolic BP 0.248 0.147

Change in heart rate 0.49 0.045

Change in LV GLS 0.70 < 0.0001 0.001

Change in LV EDV 0.350 0.106

Ultrafiltration rate [mL/kg/h] 0.80 < 0.0001 < 0.0001

BP — blood pressure; EDV — end-systolic volume; GLS — global longitudinal strain; LV — left ventricle

(6)

a physiologic and expected response to a loss of fluid and modest decrease in afterload. The heart rate of subjects studied increased after HD as a phy- siologic response to reduced circulating volume.

Impact of HD on circulating hs-cTn levels In present study, an almost 30% relative in- crease in hs-cTn levels was found. In available literature, conflicting results have been presented about cTn change with HD [7, 8, 10–13, 20–22]. The current perception is to expect a modest relative decrease in circulating cTn levels after HD [13].

However, the rate of ultrafiltrated volume could also have an impact on cTn change. The current study showed that ultrafiltrated volume showed a strong correlation with the relative change in hs-cTn levels.

Elevated cTn concentrations after HD may reflect increased concentration due to reduced clearance with limited residual renal function [24].

Recurrent myocardial damage could be a potent reason for cTn elevation [15]. Since the present population had a mean of almost 7 years for receiv- ing HD, chronicity of renal replacement therapy could have caused cardiac and renal structural damage which could lead to a cTn increase in each session of HD. Moreover, it has been claimed that HD can lead to myocardial stunning especially in high ultrafiltration rates which can also lead to acute elevation of hs-cTn T levels [14, 25]. Since these patients are at greater risk of coronary artery disease development, high volume depletion may cause reflex tachycardia and ischemia as a result of supply-demand mismatch during HD sessions, which may contribute to cTn elevation as well as LV hypertrophy.

Impact of HD on echocardiographic parameters

Although LV and left atrial dimensions, areas and volumes were significantly reduced, no sig- nificant change in LV EF was observed. Since EF is a relative measurement, volume change is not expected to affect EF measurements in individuals with normal systolic function. Nonetheless, there are conflicting findings about LV EF change with volume depletion evidenced in research literature, which could be due to differing sample sizes and methodologies of the studies.

Two-dimensional speckle tracking is a method developed for functional assessment of LV. 2D speckle tracking derived GLS has now emerged as a new index of LV function [19, 26]. GLS appears to be robust and more sensitive for detection of subtle functional changes, providing complementary and

superior information over conventional LV EF meas- urements [27, 28]. In the present study, a significant reduction in LV GLS by being highly affected from volume change was found. Myocardial stunning could also lead to a decrease in LV GLS by having an impact on myocardial contractility. LV systolic func- tion evaluated with GLS during and after HD may present cardiac systolic dysfunction. Thus patients should be closely monitored and clinicians should be aware of possible transient, cardiac decompensation, considering concomitant hs-cTn elevation.

Clinical perspective of hs-cTnT increase after HD

Chest pain is the most common cause of visits to emergency department and almost one-quarter of these patients are diagnosed with acute coro- nary syndrome [1, 4]. To exclude acute myocardial infarction in patients with acute onset of chest pain, 6–12 h of follow-up was needed with older generations of cTn assays [4, 29]. It was therefore raising a significant burden on the health care system and the possibility of developing faster diagnostic algorithms would be a great advantage [4]. Patients with end stage kidney disease have increased circulating cTn levels. In the present population cTn levels were shown to be high but stable compared to reference values. However, conflicting findings are present on the acute effect of HD on cTn levels [8, 13, 24, 30]. Nevertheless, clinicians must mainly rely on cTn measurements since patients with chronic kidney disease also have the most cardiovascular risk factors and ischemic findings on electrocardiography which could be present due to LV hypertrophy. High blood pressure, hyperdynamic circulation due to arteriovenous shunt, volume overload and increa- sed pulse pressure can cause myocardial strain and result in elevated cTn in this population [14, 15, 25]. Moreover, recurrent myocardial damage due to decreased myocardial blood flow caused by HD plays an important role in cardiac remodeling [14, 16]. Thus, high ultrafiltration rates and volumes are especially shown to be associated with myocar- dial stunning [25]. Herein an almost 30% relative increase in hs-cTnT levels with HD and it was demonstrated that this increase is highly correlated with the ultrafiltration rate. It was also shown that high ultrafiltration volumes have a substantial impact on systolic function of LV. Relative change in LV GLS also showed a very strong correlation with the ultrafiltrated rate. Moreover, LV GLS was found to be one of the strongest independent variables in relation to a relative hs-cTnT increase.

(7)

Therefore, it can be claimed that the rate of ul- trafiltration has a substantial impact on hs-cTnT change and myocardial contractility which can be also related to an hs-cTnT increase. As suggested in the recent guidelines [25], ultrafiltration rates and volumes should be minimized to suit what is best for patients to achieve hemodynamic stabil- ity and tolerability. Additional HD sessions should be considered for patients instead of extensive ultrafiltration rates [25]. Patients on HD therapy presenting with chest pain must still be managed by measuring serial cTn levels, the change in cTn may help in clinical decision making as to whether it is acute coronary syndrome or not.

Limitations of the study

In this present study it was endeavoured to enrol an adequate number of patients to represent a population with end-stage kidney disease. There was no possibility of telemetric monitoring or ob- taining electrocardiogram records which may have played an additional role on possible causes of cTn elevation before and after HD, however it was not needed clinically since none of subjects had related symptoms. Since patients with coronary artery disease were excluded and the present population included patients without previous coronary an- giogram, an inability to evaluate the possible role of significant coronary stenosis causing ischemia in these patients might have interfered with the results. The aim of this study was to investigate the acute effects of HD on hs-cTnT levels and its rela- tion with ultrafiltration rate and therefore, hs-cTnT measurements on 12th or 24th h after HD could not be presented. Moreover, HD has various effects on cardiovascular dynamics, although we found ultrafiltration rate and LV GLS as independent variables related to a relative increase of hs-cTnT, exact mechanisms of this increase in hs-cTnT level require further investigation and cannot be quin- tessentially elucidated with the present findings.

To avoid possible variability in measurements of echocardiographic parameters, a single observer (SÜ), who has substantial experience in echocar- diography and deformation imaging, performed all echocardiographic analyses of the image datasets.

Conclusions

In the present study, it was shown that hs- -cTnT levels show a significant increase after HD which can jeopardize the accuracy of clinical diag- noses based on hs-cTnT measurements. A strong correlation was present among relative changes in

hs-cTnT levels, LV GLS, and ultrafiltration rate. LV GLS was found to be one of the strongest independ- ent variables associated with the relative hs-cTnT increase. Rapid volume depletion substantially effected myocardial contractility and resulted in possible myocardial damage. The rate of ultrafiltra- tion should be minimized to avoid possible negative consequences. Considering the effect of HD with high ultrafiltration rate on circulating hs-cTnT levels, it could be of use to prevent misdiagnosis.

Conflict of interest: None declared

References

1. Thygesen K, Alpert J, Jaffe A, et al. Third universal definition of myocardial infarction. Nat Rev Cardiol. 2012; 9(11): 620–633, doi:10.1038/nrcardio.2012.122.

2. Westermann D, Neumann JT, Sörensen NA, et al. High-sensitiv- ity assays for troponin in patients with cardiac disease. Nat Rev Cardiol. 2017; 14(8): 472–483, doi: 10.1038/nrcardio.2017.48, indexed in Pubmed: 28383022.

3. Apple FS, Collinson PO. Analytical characteristics of high-sensi- tivity cardiac troponin assays. Clin Chem. 2012; 58(1): 54–61, doi:

10.1373/clinchem.2011.165795, indexed in Pubmed: 21965555.

4. Roffi M, Patrono C, Collet JP, et al. 2015 ESC Guidelines for the management of acute coronary syndromes in patients present- ing without persistent ST-segment elevation: Task Force for the Management of Acute Coronary Syndromes in Patients Present- ing without Persistent ST-Segment Elevation of the European Society of Cardiology (ESC). Eur Heart J. 2016; 37(3): 267–315, doi: 10.1093/eurheartj/ehv320, indexed in Pubmed: 26320110.

5. Hassan HC, Howlin K, Jefferys A, et al. High-sensitivity troponin as a predictor of cardiac events and mortality in the stable dialy- sis population. Clin Chem. 2014; 60(2): 389–398, doi: 10.1373/

/clinchem.2013.207142, indexed in Pubmed: 24185551.

6. Mishra RK, Li Y, DeFilippi C, et al. CRIC Study Investigators.

Association of cardiac troponin T with left ventricular struc- ture and function in CKD. Am J Kidney Dis. 2013; 61(5):

701–709, doi: 10.1053/j.ajkd.2012.11.034, indexed in Pubmed:

23291148.

7. Pianta TJ, Horvath AR, Ellis VM, et al. Cardiac high-sensitivity troponin T measurement: a layer of complexity in managing haemodialysis patients. Nephrology (Carlton). 2012; 17(7):

636–641, doi: 10.1111/j.1440-1797.2012.01625.x, indexed in Pubmed: 22694299.

8. Kumar N, Michelis MF, DeVita MV, et al. Troponin I levels in asymptomatic patients on haemodialysis using a high-sen- sitivity assay. Nephrol Dial Transplant. 2011; 26(2): 665–670, doi: 10.1093/ndt/gfq442, indexed in Pubmed: 20656755.

9. deFilippi C, Wasserman S, Rosanio S, et al. Cardiac troponin T and C-reactive protein for predicting prognosis, coronary ath- erosclerosis, and cardiomyopathy in patients undergoing long- term hemodialysis. JAMA. 2003; 290(3): 353–359, doi: 10.1001/

/jama.290.3.353, indexed in Pubmed: 12865376.

10. Yakupoglu U, Ozdemir FN, Arat Z, et al. Can troponin-I predict cardiovascular mortality due to myocardial injury in hemodialysis patients? Transplant Proc. 2002; 34(6): 2033–2034, indexed in Pubmed: 12270303.

(8)

11. Apple FS, Murakami MM, Pearce LA, et al. Predictive value of cardiac troponin I and T for subsequent death in end-stage renal disease. Circulation. 2002; 106(23): 2941–2945, indexed in Pubmed: 12460876.

12. Fredericks S, Chang R, Gregson H, et al. Circulating cardi- ac troponin-T in patients before and after renal transplanta- tion. Clin Chim Acta. 2001; 310(2): 199–203, indexed in Pub- med: 11498086.

13. Chen M, Gerson H, Eintracht S, et al. Effect of Hemodialysis on Levels of High-Sensitivity Cardiac Troponin T. Am J Cardiol.

2017; 120(11): 2061–2064, doi: 10.1016/j.amjcard.2017.08.026, indexed in Pubmed: 29033047.

14. Dasselaar JJ, Slart RH, Knip M, et al. Haemodialysis is associ- ated with a pronounced fall in myocardial perfusion. Nephrol Dial Transplant. 2009; 24(2): 604–610, doi: 10.1093/ndt/gfn501, indexed in Pubmed: 18775808.

15. Burton JO, Jefferies HJ, Selby NM, et al. Hemodialysis-induced cardiac injury: determinants and associated outcomes. Clin J Am Soc Nephrol. 2009; 4(5): 914–920, doi: 10.2215/CJN.03900808, indexed in Pubmed: 19357245.

16. Bemelmans RHH, Boerma EC, Barendregt J, et al. Changes in the volume status of haemodialysis patients are reflected in sublingual microvascular perfusion. Nephrol Dial Transplant.

2009; 24(11): 3487–3492, doi: 10.1093/ndt/gfp267, indexed in Pubmed: 19515801.

17. Hensen LCR, Goossens K, Delgado V, et al. Prognostic im- plications of left ventricular global longitudinal strain in pre- dialysis and dialysis patients. Am J Cardiol. 2017; 120(3):

500–504, doi: 10.1016/j.amjcard.2017.04.054, indexed in Pub- med: 28579125.

18. Krishnasamy R, Isbel NM, Hawley CM, et al. Left ventricular global longitudinal strain (GLS) is a superior predictor of all- cause and cardiovascular mortality when compared to ejection fraction in advanced chronic kidney disease. PLoS One. 2015;

10(5): e0127044, doi: 10.1371/journal.pone.0127044, indexed in Pubmed: 25978372.

19. Lang R, Badano L, Mor-Avi V, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the Euro- pean Association of Cardiovascular Imaging. Eur Heart J Cardio- vasc Imaging. 2015; 16(3): 233–271, doi: 10.1093/ehjci/jev014.

20. Peetz D, Schütt S, Sucké B, et al. Prognostic value of troponin T, troponin I, and CK-MBmass in patients with chronic renal failure.

Med Klin (Munich). 2003; 98(4): 188–192, doi: 10.1007/s00063- 003-1243-3, indexed in Pubmed: 12715142.

21. Schmidt A, Stefenelli T, Schuster E, et al. Informational contribu- tion of noninvasive screening tests for coronary artery disease in patients on chronic renal replacement therapy. Am J Kidney Dis.

2001; 37(1): 56–63, indexed in Pubmed: 11136168.

22. Conway B, McLaughlin M, Sharpe P, et al. Use of cardiac tro- ponin T in diagnosis and prognosis of cardiac events in pa- tients on chronic haemodialysis. Nephrol Dial Transplant. 2005;

20(12): 2759–2764, doi: 10.1093/ndt/gfi125, indexed in Pub- med: 16188899.

23. Mavrakanas TA, Sniderman AD, Barré PE, et al. High ultrafiltra- tion rates increase troponin levels in stable hemodialysis patients.

Am J Nephrol. 2016; 43(3): 173–178, doi: 10.1159/000445360, indexed in Pubmed: 27064739.

24. Ellis K, Dreisbach AW, Lertora JL. Plasma elimination of cardiac troponin I in end-stage renal disease. South Med J. 2001; 94(10):

993–996, indexed in Pubmed: 11702827.

25. Daugirdas J, Depner T, Inrig J, et al. KDOQI Clinical Practice Guideline for Hemodialysis Adequacy: 2015 Update. Am J Kid- ney Dis. 2015; 66(5): 884–930, doi: 10.1053/j.ajkd.2015.07.015.

26. Voigt JU, Pedrizzetti G, Lysyansky P, et al. Definitions for a Common Standard for 2D Speckle Tracking Echocardiography:

Consensus Document of the EACVI/ASE/Industry Task Force to Standardize Deformation Imaging. J Am Soc Echocardiogr. 2015;

28(2): 183–193, doi: 10.1016/j.echo.2014.11.003.

27. Galderisi M, Cosyns B, Edvardsen T, et al. Standardization of adult transthoracic echocardiography reporting in agreement with recent chamber quantification, diastolic function, and heart valve disease recommendations: an expert consensus docu- ment of the European Association of Cardiovascular Imaging.

Eur Heart J Cardiovasc Imaging. 2017; 18(12): 1301–1310, doi: 10.1093/ehjci/jex244, indexed in Pubmed: 29045589.

28. Farsalinos KE, Daraban AM, Ünlü S, et al. Head-to-Head Com- parison of Global Longitudinal Strain Measurements among Nine Different Vendors: The EACVI/ASE Inter-Vendor Comparison Study. J Am Soc Echocardiogr. 2015; 28(10): 1171–1181, e2, doi: 10.1016/j.echo.2015.06.011, indexed in Pubmed: 26209911.

29. Saenger AK, Beyrau R, Braun S, et al. Multicenter analyti- cal evaluation of a high-sensitivity troponin T assay. Clin Chim Acta. 2011; 412(9-10): 748–754, doi: 10.1016/j.cca.2010.12.034, indexed in Pubmed: 21219893.

30. Fahim MA, Hayen AD, Horvath AR, et al. Biological variation of high sensitivity cardiac troponin-T in stable dialysis patients:

implications for clinical practice. Clin Chem Lab Med. 2015;

53(5): 715–722, doi: 10.1515/cclm-2014-0838, indexed in Pub- med: 25527812.

Cytaty

Powiązane dokumenty

In subgroup analyses of MetS patients, the presence of fQRS on ECG had a higher E/E’ ratio and lower E’ velocity, indicating pronounced diastolic dysfunction, as well as

Our study population comprised 3392 patients who met the following criteria: were alive on dis- charge from the hospital, received statin, 30-day MACE rate was available,

The rela- tive wall thickness and LV muscle mass measurements were performed with magnetic reso- nance imaging and patients were subdivided into four groups: Group 1 with normal

Background: The impact of radiofrequency current ablation (RFCA) on left ventricular (LV) systolic and diastolic function in patients with atrioventricular nodal re-entrant

did not observe any associations between visfatin le- vels and fasting glucose and insulin concentrations or HOMA, while our group noted a significant correlation between visfatin

The attempt proved to be successful in case of 16 women (61.53%), and they gave birth to healthy children. The first pregnancy occurred after 6 months and the last after 35 months.

The following Holter ECG parameters were measured: mean heart rate, ventricular and supraventricular extrasystoles, and parameters of HRV, including standard deviation of all normal

Methods: The ASAS group consisted of 50 patients (26 women and 24 men, aged 38.4 ± 18.1 years) meeting the echocardio- graphic criteria of severe aortic stenosis (AVA &lt; 1 cm 2 ,