Transcatheter aortic valve implantation (TAVI) in a patient with severe aortic insufficiency of aortic valve homograft

Przezcewnikowa implantacja zastawki aortalnej u pacjenta z ciężką niedomykalnością homograftu aortalnego

Zenon Huczek, Janusz Kochman, Piotr Scisło, Bartosz Rymuza, Robert Kowalik, Grzegorz Opolski

1st Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland

We present the case of a 64-year-old female who was admitted to our centre with severe aortic insufficiency and advanced heart failure symptoms (NYHA class III–IV). Her medical history included: surgical homograft aortic valve replacement due to severe aortic insufficiency 14 years ago, chronic atrial fibrillation, and hypothyroidism. The patient’s logistic EuroSCORE was 32%, EuroSCORE II 9.1%, and STS score 3.95%. Preprocedural transthoracic echocardiographic examination revealed akinesis of the basal and mid segments of interventricular septum, global hypokinesis of remaining segments with ejection fraction of 19%, enlargement of the left ventricle and atrium (diameter of 68 and 43 mm, respectively), regurgitant orifice area of 0.3 cm2, regurgitant volume of 58 mL, and regurgi-

tant jet width to left ventricular outflow tract ratio of 66%

(Fig. 1). An additional transoesophageal echocardiographic examination was performed for more precise measurement:

this showed aortic annulus diameter of 24 mm. Angiography and computed tomography were also performed, showing no lesions in either the coronary or peripheral arteries. On the basis of the abovementioned clinical conditions, the Heart Team decided to refer the patient to transcatheter aortic valve implantation (TAVI) via femoral access. The procedure was performed under general anaesthesia with a temporary pacemaker placed through the jugular vein and vascular access obtained with 18 Fr sheath by puncture of the right femoral artery. Due to lack of calcifications, two pig-tail catheters were placed in order to mark the plane of the annulus (Fig. 2) and 29 mm Medtronic CoreValveTM bioprosthesis was implanted under rapid pacing. Despite these preventive measures, the final position of prosthesis was too low with moderate-to-severe aortic insufficiency (Fig. 3) that persisted even after postdilatation with a 28 mm balloon. Therefore, the decision to implant another 29 mm CoreValve 10 to 15 mm higher was made. Finally, in control imaging, only a mild paravalvular leak was present (Fig. 4), and on discharge the ejection fraction had improved to 43%.

TAVI is an effective treatment option for severe aortic ste- nosis in inoperable and high-risk patients. However, failure (mostly insufficiency) of a previous homograft aortic valve poses a challenge for any interventional treatment. In se- lected patients, TAVI can be a feasible alternative for high risk re-operation. TAVI may also be considered in some cases of native aortic insufficiency where there is favour- able anatomy.

Address for correspondence:

Zenon Huczek, MD, PhD, 1st Chair and Department of Cardiology, Medical University of Warsaw, ul. Banacha 1A, 02–097 Warszawa, Poland, e-mail: zenon.huczek@wum.edu.pl

Conflict of interest: none declared

Figure 1. Severe homograft aortic insufficiency in colour Doppler imaging

Figure 2. Two pigtail catheters marking annulus plane (arrows)

Figure 3. Significant residual insufficiency in (A) angiography and (B) echocardiography after implantation of first prosthesis

Figure 4. Good result after placement of the second CoreValve in both angiography and echocardiography (A and B, respectively) with only a trace of regurgitation

A

A

B

B

Cytaty

Powiązane dokumenty

Aortography after insertion of a Lunderquist Extra-Stiff Wire Guide in left ventricle (LV) reveals severe AR and immobile right coronary leaflet (Suppl. Immediately after removal

1) Sustained hemodynamic changes are observed as peak velocity and transvalvular gradient dif- ferences between discharge and follow-up within 1 year after the procedure; 2) BAV

The aim of the study was to assess the risk of bleedings, their influence on early prognosis of TAVI patients and utility of the TIMI and GUSTO scales in the evaluation of bleeding

Transcatheter aortic valve implantation and hybrid coronary revascularization in a patient with severe aortic stenosis, complex coronary artery dis- ease, and porcelain aorta..

ence of >48° angle between the aortic annulus Transcatheter aortic valve implantation (TAVI)4. is a well ‑established modern treatment of severe symptomatic

dergoing aortic valve repair (BAV > TAV) suggests that many patients with AI are still considered for aortic valve repair, except for young patients with a congenital BAV.

In a sta- ble patient, the approach is to control the posi- tion of a stiff guidewire, verify the valve shape and re-balloon in the case of distortion, as well as increase

Computed tomography showed an aortic annulus area of 293 mm 2 and significant abdominal aortic stenosis with severe calcification (indicated with a yel-.. low