Simultaneous valve-in-valve procedure and life-saving coronary angioplasty in a patient with low coronary artery ostia

N/A
N/A
Protected

Academic year: 2022

Share "Simultaneous valve-in-valve procedure and life-saving coronary angioplasty in a patient with low coronary artery ostia"

Copied!
2
0
0

Pełen tekst

(1)

234 Creative Commons licenses: This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY -NC -SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/).

Image in intervention

Corresponding author:

Janusz Kochman, 1st Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland, e-mail: jkochman@wum.edu.pl Received: 6.04.2021, accepted: 8.05.2021.

Simultaneous valve-in-valve procedure and life-saving coronary angioplasty in a patient with low coronary artery ostia

Michał Walczewski, Aleksandra Gąsecka, Piotr Pęczek, Michał Marchel, Bartosz Rymuza, Janusz Kochman

1st Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland

Adv Interv Cardiol 2021; 17, 2 (64): 234–235 DOI: https://doi.org/10.5114/aic.2021.107511

A  75-year-old woman with hypertension, diabetes mellitus type 2, permanent atrial fibrillation, and chronic kidney disease was admitted to the hospital due to ex- acerbation of chronic heart failure, vertigo, and syncopal events. Transoesophageal and transthoracic echocardi- ography revealed severe stenosis and calcification of the prosthetic aortic valve (Trifecta 21 mm), mid-range left ventricle ejection fraction (LVEF) of 49%, moderate insuf- ficiency of the mitral valve, and tricuspid insufficiency with a  high probability of pulmonary hypertension. Re- garding multiple comorbidities and a high peri-operative risk (logistic EuroScore 48.6%), valve-in-valve (ViV) tran- scatheter aortic valve implantation (TAVI) was proposed by the heart team.

The pre-operative computed tomography (CT) re- vealed a  very short distance from the bioprosthesis to the coronary ostia (Figures 1 A, B: 3.0 mm and 3.9 mm to the left and right coronary artery, respectively). TAVI was performed via the right femoral artery access, us- ing transoesophageal echocardiography (TOE) guidance.

The pig-tail catheter for aortography was inserted via the left radial artery. Considering the high risk of coronary obstruction, the ostia of the right and left coronary ar- teries were engaged with JR 4.0 and JR 3.5 guiding cath- eters via the right femoral artery and left radial artery, respectively. Two undeployed drug-eluting stents (4.0 × 28 mm and 3.0 × 28 mm) were inserted into the median segments of the left anterior descending (LAD) and right coronary artery (RCA; Figure 1 C; Video S1). This tech- nique has previously been suggested as a feasible way of protecting coronary arteries in high-risk cases [1–3]. The Evolut R bioprosthesis was chosen due to lower postop- erative gradients and possible haemodynamic advantage over other models due to its supra-annular design [4].

Following the implantation of the Evolut R 23 mm, the

patient experienced ventricular fibrillation and sudden cardiac arrest. Both stents were immediately moved to the ostia of the RCA and left main and deployed using the double-chimney technique, allowing restoration of coronary blood flow (Figure 1 D; Video S2). After sever- al defibrillation attempts, the haemodynamically stable rhythm returned. Control aortography showed normal coronary blood flow (Figure 1 E; Video S3) and a  aor- tic valve peak-to-peak gradient of 10–12 mm Hg. TOE showed a fully expanded Evolut R valve, with no evidence of paravalvular leak (Figures 1 F, G). Following closure of the femoral artery with the ProGlide system, an occlu- sion of the deep femoral artery was visible on routine angiography check-up (Figure 1 H), which was success- fully treated with a percutaneous angioplasty (compliant balloon 5.0 × 15 mm; Figure 1 I). Following the procedure, the patient’s condition improved, showing no symptoms of overt heart failure and no neurological defects. Control echocardiography showed appropriate function of the prosthetic valve and LVEF of 47%.

Considering the growing popularity of TAVI and the ongoing demographic changes, there is a  need for the development of guidelines that will enable safe TAVI in specific subpopulations of patients, such as those with low coronary arteries or undergoing ViV procedures, which have an increased risk of potentially fatal coronary obstruction [5].

In our patient, a thorough CT-based preparation en- abled the deployment of coronary stents as a life-saving treatment of coronary artery obstruction following bio- prosthesis implantation. Furthermore, this case high- lights that TAVI carries a risk of vascular site complica- tions, especially if the puncture site is not optimal, as in our patient. Ultrasonography-guided puncture might help to choose the optimal puncture site.

(2)

Michał Walczewski et al. ViV and PCI in a patient with low coronary artery ostia

235

Advances in Interventional Cardiology 2021; 17, 2 (64)

Conflict of interest

The authors declare no conflict of interest.

References

1. Kabach M, Alrifai A, Lovitz L, et al. Successful coronary protec- tion during TAVI in heavily calcified aortic leaflets in patient with short and low left coronary system. Case Reports Cardiol 2018;

2018: 2758170.

2. Gonzálvez-Garcia A, Hernández-Matamoros H, Jurado-Román A, et al. Valve in valve procedure and left main stent: to deliver or not to deliver. Cardiol J 2020; 27: 87-8.

3. Armijo G, Nombela-Franco L. Transcatheter aortic valve implan- tation in extremely low coronary arteries. EMJ Int Cardiol 2018;

6: 53-4.

4. Bapat V. Technical pitfalls and tips for the valve-in-valve proce- dure. Ann Cardiothorac Surg 2017; 6: 541-52.

5. Baumgartner H, Falk V, Bax JJ, et al. 2017 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J 2017;

38: 2739-91.

Figure 1. A, B – Distance between the bioprosthesis and coronary arteries; C – undeployed stents in the mid segments of left anterior descending and right coronary arteries; D – deployed stents after Evolut R implan- tation, complicated with sudden cardiac arrest; E – patent coronary tree; F, G – degenerated Trifecta biopros- thesis (*) and newly implanted, fully expanded Evolut R valve (**), with no evidence for paravalvular leak in the long-axis and short-axis views in transoesophageal echocardiography; H – occluded deep femoral artery;

I – patent deep femoral artery following balloon angioplasty

A B

C D E

F G H I

Cytaty

Powiązane dokumenty

A 65-year-old female patient with hypertension, obesity, dyslipidaemia, and stable angina, who was treated with primary percutaneous coronary intervention (PCI) of the left

Acute myocardial infarction was diagnosed, and the patient underwent immediate coronary angiography, which revealed normal left coronary artery (LCA) (Fig. 2) and thrombotic

Taking into consideration the persistent huge thrombus and the risk of “no-flow” phenomenon we decided to insert a Filter-Wire (Boston Scientific) for distal protec- tion and to use

Acute coronary syndrome in a patient with an anomaly of the right coronary artery, which originated from the medial part of the left anterior descending artery.. Ostry

Patient 2: An 82-year-old male patient with a history of chronic left bundle branch block and ST elevation ACS 12 years ago, treated with primary PCI of the left anterior

Anna Posadzy-Małaczyńska, MD, PhD, Department of Hypertensiology, Angiology and Internal Diseases, Poznan University of Medical Sciences, ul. RCA with the fistulous connection to

najczęstsze anomalie wieńcowe to: rozdzielenie prawej tętnicy wieńcowej (podwójny przebieg tętnicy tylnej zstępu- jącej) (1,23%), ektopowa prawa tętnica wieńcowa (1,13%),

Key words: abnormal origin of right coronary artery, ventricular tachycardia, implantable cardioverter-defibrillator, endomyocardial biopsy, arrhythmogenic right