• Nie Znaleziono Wyników

Giant intrathoracic haematoma compressing the left atrium after PCI for degenerated saphenous vein graft

N/A
N/A
Protected

Academic year: 2022

Share "Giant intrathoracic haematoma compressing the left atrium after PCI for degenerated saphenous vein graft"

Copied!
1
0
0

Pełen tekst

(1)

www.kardiologiapolska.pl

Kardiologia Polska 2014; 72, 10: 984; DOI: 10.5603/KP.2014.0195 ISSN 0022–9032

Studium przypadku / CliniCal Vignette

Giant intrathoracic haematoma compressing the left atrium after PCI for degenerated

saphenous vein graft

Angioplastyka zdegenerowanego graftu żylnego powikłana olbrzymim krwiakiem śródpiersia uciskającym lewy przedsionek

Maksymilian Mielczarek

1

, Miłosz Jaguszewski

1, 2

, Joanna Wdowczyk

1

, Dariusz Ciećwierz

1

, Marcin Gruchała

1

11st Department of Cardiology, Medical University of Gdansk, Gdansk, Poland

2University Heart Centre, University Hospital of Zurich, Zurich, Switzerland

A 61-year-old male patient with a 17-year history of coronary multi-vessel disease and coronary artery bypass graft (CABG) was admitted for the exacerbation of angina. Bedside echocardiography demonstrated hypokinesis in basal, posterior and lateral segments of the left ventricle (LV). Coronary angiography revealed a chronic occlusion of both native coronary arteries and two critical lesions in saphenous vein graft (SVG) to posterolateral branch of the circumflex coronary artery. Therefore, we subsequently attempted percutaneous coronary intervention (PCI) for the degenerated SVG utilising Judkins R4 8 French guiding catheter and SpideRX Embolic Protection Device for distal embolic protection. Both lesions were predilated using a 4.0 × 20 mm Maverick balloon. The distal lesion was covered with bare-metal stent (5.0 × 13 mm Pro-Kinetic) fol- lowed by self-expanding 7.0 × 30 mm Wallstent implanted to cover the proximal stenosis. A second stent was postdilated with a 5.0 × 15 mm Maverick balloon. The periprocedural course was uneventful and a satisfactory angiographic result was achieved. Several hours after the PCI, the patient complained of chest pain. Serial electrocardiographic records did not reveal new ischaemic changes, and echocardiography identified neither new segmental LV systolic dysfunction nor hydropericardium. Due to a positive troponin test and the fulfilled criteria of periprocedural myocardial infarction (MI), hospitalisation was prolonged. A three-day-echocardiography documented a structure suggesting a large thrombus in the left atrium (LA) or a large mass pressing upon the LA from outside (Figs. 1A, B). Computed tomography angiography (CTA) identified a large mass of 80 mm × 82 mm × 86 mm adjoining the right wall of treated SVG (Fig. 1C). Urgent coronary angiography excluded SVG perforation. The patient remained asymptomatic with no haemodynamic compromise, and a conservative treatment strategy was applied. A CTA per-

formed after ten days showed a reduction of mediastinal haematoma. Due to frequent episodes of paroxysmal atrial fibrillation and non-sustained supraventricular tachycardia, therapy with sotalol and warfarin was implemented. The patient was discharged home on the 26th day. A month later, echocardiography (Fig. 1D) and CTA documented further haematoma resolution. The patient continues to do well 12 months after the index event. SVG degeneration is the drawback of this commonly used technique of CABG. Poten- tially life-threatening SVG rupture remains a rare complica- tion and can be discovered incidentally. The initial strategy is to prevent blood leakage by prolonged inflation of the balloon prior to rupture. Frequently, final implantation of stent graft is necessary. Successful treatment may however be hampered by the lack of an appropriate stent graft ‘off the shelf’, because of the abnormally large diameter of degenerated SVG. We here present a case of particular clinical significance where an intrathoracic haematoma that compressed the LA occurred after PCI of SVG with a clinical presentation of periprocedural MI but with no haemodynamic compromise, and thus treated conservatively with an elegant result.

Address for correspondence:

Maksymilian Mielczarek, MD, 1st Department of Cardiology, Medical University of Gdansk, ul. Dębinki 7, 80–952 Gdańsk, Poland, e-mail: max.mielczarek@gmail.com Conflict of interest: none declared

Figure 1. A. Parasternal long axis view; B. Apical four-cham- ber view; C. Computed tomography angiography transverse plane; D. Apical four-chamber view; asterisk — intrathoracic haematoma; LA — left atrium; LV — left ventricle

A

D C

B

Cytaty

Powiązane dokumenty

Saphenous vein graft (SVG) to the left anterior descending artery: significant stenosis of proximal, medial, and distal segments (red arrow).. Non-compliant balloon underexpansion

Based on the fact that no ‑reflow phenomenon is characterized by thromboembolic pathophysiology, we investigated the relationship between the CHA 2 DS 2 ‑VASc score and no

men: 1) the length of the course of the oblique vein (measured from its ostium until the most prominent extension of the main trunk of the vessel was no longer visible);

tuous, fistula was observed from the circumflex artery to the bronchial arteries of the left lower lobe.. Due to the high number of

flex coronary artery (LCx) origin is the most common (18.3% of all CAFs

Compared with patients who underwent bypass graft PCI, those who underwent native coronary artery PCI were more likely to undergo PCI of a chronic total occlusion (CTO) or to

A giant aorta (AO)-left artery descending graft aneurysm demonstrated by transthoracic echocardiography (A, B), angiography (C, arrow) and three-dimensional computed

Ascending aortic pseudoaneurysms are very rare entities generally occurring after heart surgery associated with cannulation for cardiopulmonary pump or aorta-coronary artery