• Nie Znaleziono Wyników

Characterising fire hazard from temporal sequences of thermal infrared MODIS measurements (poster)

N/A
N/A
Protected

Academic year: 2021

Share "Characterising fire hazard from temporal sequences of thermal infrared MODIS measurements (poster)"

Copied!
1
0
0

Pełen tekst

(1)

Characterising Fire Hazard from Temporal Sequences of

Thermal Infrared MODIS Measurements

Carmine Maffei

1

, Silvia Alfieri

2

, Massimo Menenti

1

1)  Department of Geoscience and Remote Sensing, Delft University of Technology (Netherlands)

2)  Institute for Agricultural and Forest Systems in the Mediterranean, National Research Council (Italy)

Vegetation moisture and temperature are the most variable factors determining fire hazard. Prolonged heat and absence of rainfall drive vegetation into water stress conditions; this leads to an increase (anomaly) of vegetation temperature that can be recorded by remote sensing instruments. Since stressed vegetation is more prone to fire, there might be a potential role for Earth observation technologies in mapping fire hazard.

To identify anomalies, reference temperatures against which evaluate current measurements must be defined. The HANTS (Harmonic ANalysis of Time Series) algorithm may accomplish this task, but its effectiveness in providing a reference useful for the assessment of fire hazard is still unexplored.

The objective of the present research was to characterise fire hazard from anomalies of daily land surface temperature (LST) derived from MODIS measurements. Since maps of HANTS coefficients provide a detailed characterisation of the spatial and temporal pattern of surface temperatures, their potential to explain spatial patterns of fire events was also investigated.

1 Introduction

Yearly maps of Fourier coefficients were classified by segmenting their values. Spatial patterns of fire number and burnt area were assessed in terms of selectivity, i.e. by understanding whether in each class fire incidence is higher (preferred) or lower (avoided) than expected from a random null model.

Daily maps of thermal anomalies (TA) were computed by subtracting the daily reference temperature from current MODIS LST. Cumulated thermal anomalies (CTA) were calculated as the sum of all the observed thermal anomalies from the day when the thermal anomaly was first recorded in a pixel up to the current day.

The values of TA and CTA were sampled at fire’s location in the day previous to the event, and evaluated against fire size by calculating the conditional mean fire size observed when the TA (CTA) was larger of the considered value. Similarly, the conditional proportion of large fires (> 16 ha) was calculated.

2 Materials and methods

Mean annual temperature and the amplitudes of the three harmonics used in the Fourier analysis determine spatial patterns of fire occurrence. The only phase component of the Fourier analysis related to fires incidence is that of the first harmonic: a larger number of fires is observed where the phase is higher, i.e. when a prolonged warm season occurs.

Anomalies of LST are related to the fire size that can be expected in a given area, with CTAs being more sensitive than TAs. CTA is a measure of heat “accumulated” in a certain area, providing more direct information on the prolonged exposure of vegetation to stress conditions. This is reflected in the prediction of expected mean fire size over two orders of magnitude, allowing the production of more meaningful fire hazard maps as compared to TA.

4 Discussion

T h e r e s e a r c h f o c u s s e d o n Campania, Italy (13595 km2). The

Italian Forest Corps provided a dataset of more than 4400 fire records covering years between 2000 and 2006. Data included date and time, coordinates, duration, extent and presumed causes of each event. A collection of daily Terra-MODIS LST data from 2000 to 2006 was used for our analyses. 270 280 290 300 310 320 50 100 150 200 250 300 350 Temperature (K)

Day of the year

The HANTS algorithm handles the Fourier analysis as a curve-fitting problem. Basing on an iterative approach, invalid observations are removed and the best fitting series is identified. Series comprising three harmonics (365, 180 and 120 days) were fit to the data with two methods: separately on each yearly sequence of LST data; on the whole 2000-2006 dataset to construct daily maps of reference temperature.

Fires are selective towards Fourier coefficients, and tend to prefer areas where the mean temperature and the amplitude of the first harmonic have higher values, and to avoid low values. Fires also prefer areas where the amplitudes of the second and third harmonic are low, and where the phase of the second harmonic is high. Mean fire size shows selectivity only towards the amplitude of the second harmonic (see table below).

Daily maps of thermal anomalies (left, below) and cumulated thermal anomalies (right) carry different information (date is 15 July 2001 in the example).

With increasing values of thermal anomaly, the conditional mean fire size increases (left, below). A similar trend is observed with the conditional fraction of fires larger than 16 ha (right).

Increasing values of cumulated thermal anomaly lead to larger fires (left, below). As opposed to TA, the ranges of values of mean fire size and fraction of large fires that can be mapped from CTA are considerably larger.

5 5.5 6 6.5 7 7.5 8 8.5 9 0 1 2 3 4 5 6 7 8

Mean fire size | TA>x (ha)

Thermal anomaly (K) 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0 1 2 3 4 5 6 7 8

Fraction of fires > 16 ha | TA>x

Thermal anomaly (K) 0 50 100 150 200 250 0 10 20 30 40 50 60 70 80

Mean fire size | CTA>x (ha)

Cumulated thermal anomaly (K)

0.05 0.1 0.15 0.2 0.25 0.3 0.35 0 10 20 30 40 50 60 70 80

Fraction of fires > 16 ha | CTA>x

Cumulated thermal anomaly (K)

3 Results

Amplitude of the second harmonic (180 days) Class (K) Number of fires Mean fire size (ha)

0-1 2083 +++ 3.52 ---

1-2 1723 - 6.01 ++

2-3 570 --- 7.24 ++

>3 28 --- 1.,85 ++

Selectivity of fires towards classes of amplitude of the second harmonic. Symbol “+” means preference, “-” avoidance. One symbol: selectivity non significant. Two symbols: significant P<0.05. Three symbols: significant P<0.01. C u mu la te d th e rma l a n o ma ly (K) " T h e rma l a n o ma ly (K) "

Cytaty

Powiązane dokumenty

Ponadto grupa badana wykazuje wyższy niż grupa kontrolna poziom lęku jako stanu i lęku jako cechy, a także wyższy poziom motywu transgresyjnego oraz wyższy

The aim of the present paper, which presents the fifth part of the case study, was to explore the influence of lexical and syntactic complexity on the development of fluency

eksplozję klasy średniej na świecie. powstanie blisko 2 mld do- datkowej oprócz obecnej klasy średniej. W samych Chinach do tego czasu liczba osób należących do

Three-dimensional spatial filtering and measurement noise associated with experimental particle image velocimetry (PIV) measurements of wall-bounded flows are investigated via

W artykule omówiono dostępne w literaturze krajowej oraz zagranicznej wskaźniki emisji dla kotłów i innych urządzeń zasilanych gazem ziemnym, które pozwalają na

Zwracał również uwagę na tak istotne czynniki, jak skonsolidowanie elementów dotyczących kwestii edukacji, zatrudnienia, zdrowia i zamieszkania Romów podkreślając, iż

I padri conciliari, preoc- cupandosi della formazione pastorale degli alunni, scrivono, che è necessa- rio l’accurato insegnamento dell’arte di dirigere anime, per mezzo della qua- le

Jako iż trudno wyobrazić sobie sytuację, w której Turcja mogłaby stać się człon- kiem UE, nie uznając jednego z państw członkowskich podczas konferencji prasowej z