• Nie Znaleziono Wyników

2.7 An Example of Deterministic Analysis of Cable-Stayed Bridges

2.7.3 Geometry and Material Properties of Structural Members

In this section a short descriptions of cross-sectional areas chosen for main elements of the structures are presented. Additionally the geometrical and material characteristics for particular members of the object [7,10,19,21,41,47] that are put to the program at the stage of creating the model. All details of the equation that were used by determining the obtained values can be found in [63].

2.7.3.1 Pylon

Seri Wawasan Bridge becomes an inspiration of making this examples, however in the process of creating the model, the concept of the pylon with the shape of an inverted-Y, is rejected. For simplification of the scheme the caisson cross-section, that is presented n Fig.2.24, is assumed.

z y

Figure 2.24 Adopted caisson cross-section of the pylon [m]

For the proper giving the characteristics of the adopted cross-section, that are input data to the numerical programm, the local axis ordination of the element needs to be defined. Therefore they can be found in Fig. 2.25.

An Example of Deterministic Analysis of Cable-Stayed Bridges • 47

O

x

z y

Figure 2.25 Pylon’s local coordinate system

Moments of inertia with respect to local axis [52], presented in Fig. 2.25, read Jpy = Jpz = 5× 53

12 − 3× 33

12 = 45, 33(3) m4 Jpx = 45, 33 + 45, 33 = 90, 66 m4

The cross-section area of the considered element is expressed by the equation Ap = 5 × 5 − 3 × 3 = 16 m2

Assuming that γpm = 25 kN/m3is the self weight of reinforced concrete, and γf is the safety coefficient, the characteristic Gpk and computational Gpd values of pylon’s dead load are equal respectively

Gpk = Apγpm = 16 × 25 = 400 kN/m

Gpd = Apγpmγf = 16 × 25 × 1, 2 = 480 kN/m

2.7.3.2 Arches

It is possible to model lengthwise variable cross-section of the arches by using shell elements, but this approach will make the computation much more complicated. Therefore, the constant values of the arches’ cross-section area are adopted to the input data — see Fig. 2.26.

y

z

y z

Figure 2.26 Accepted pipe cross-section of the arches [m]

The characteristics for the described beam element are obtained on the basis of following local coordinate system — Fig. 2.27.

x

O z

y

Figure 2.27 Local axis ordination in the arches’ beam elements

Moments of inertia received for local axes from Fig. 2.27 are equal Jay2 = Jz2 = π

4(1, 754− 1, 724)= 0, 4922684758 m4

Jax2 = 0, 4922684758 + 0, 4922684758 = 0, 9845369516 m4 The cross-section area of the single arch is given by the below formula

Aa = π(1, 752− 1, 722)= 0, 32704 m2

It should be noticed that the most suitable material for the structure with this kind of shape is steel. Therefore for gaining the characteristic and computational values of arch’s dead load — Gak and Gad, the unit-volume weight γam = 78, 5 kN/m3is assumed

Gak = Aaγam = 0, 32704 × 78, 5 = 25, 67 kN/m

Gad = Aaγaf = 0, 32704 × 78, 5 × 1, 2 = 30, 81 kN/m

2.7.3.3 Span

In the created model of suspended bridge, the following dimensions of main span are adopted:

width — 40 m, total length — 220 m. At first, it was designed as a reinforced concrete plate with the thickness equal 30 cm. Due to the large values of obtained vertical displacements from the static loads, the plate is strengthened with longitudinal and crosswise steel ribs. When enter-ing the model to the program some simplifications are applied. We assumed that the thickness center of the plate coincide with the middle points of the ribs’ hight — mentioned problem is illustrated in Fig. 2.28. Accurate reflection of the span’s work and connection between the ele-ments may encounter many problems and makes the computations much more time-consuming.

The necessary input data for the plate are the components of constitutive matrix (see section 2.1), that can be expressed by the equation

 σx x σyy σxs

=

Cx x Cx y Cxs Cyy Cys

sym. Gx y

 ǫx x ǫyy γxs

An Example of Deterministic Analysis of Cable-Stayed Bridges • 49

During following data processing, the maximum vertical displacement of the plate turns out to be to large. Therefore by the council from the experts, we took characteristics of special composite material:E =10000 kN

cm2 and ν = 0, 25 for research. Using this values the particular terms of constitutive matrix are obtained

Cx x = Cyy = E

1− ν2 = 10666, 67kN cm2 Cx y = E ν

1− ν2 = 2666, 67kN cm2 Cxs = Cys = 0

Gx y = E

2(1+ ν) = 4000 kN cm2

Assuming γplm = 25 kN/m3, and plate’s thickness d = 30cm, we obtain the characteristic and computational values of plate’s dead load

Gplk = dγplm = 0, 30 × 25 = 7, 5 kN/m2

Gpld = dγplmγf = 0, 30 × 25 × 1, 2 = 9, 00 kN/m2

Figure 2.28 Simplified view of plate model design for the experiment

2.7.3.4 Ribs

The plate is strengthened by steel instead of reinforced concrete ribs, according to Fig. 2.29.

Figure 2.29 Dimensions of rib’s cross-sections [cm]

Geometry properties are adopted on the basis of [8]. Moments of inertia are equal respectively

Jr y = 3395400 cm4 (2.161)

Jr z = 54210 cm4

Jr x = Jr y + Jr z = 3449610 cm4

Cross-section area for element from Fig. 2.23 is Ar = 532 cm2

Values of rib’s dead load are given in the form Gr k = = 4, 256 kN/m

Gr d = Gr kγf = 4, 256 × 25 × 1, 2 = 5, 1072 kN/m

2.7.3.5 Cables

In data processing the ropes in the form of seven galvanized wires φ5mm in the HDPE coat, are adopted — see Fig. 2.30. This type of cables are the most widespread. The main material characteristics are assumed on the basis of [7,38]: yield stress — σc = 1670 MPa, breaking strength — Rpk = 1870 MPa, and elasticity modulus — Ec = 200 GPa.

Appointing the necessary values of cross-section areas the main cables is a quite complex issue and for this example it is shown in details in [63]. This values for particular cables are between 25, 57cm2and 38, 29cm2. For simplification, the constant values of cross-section areas of these suspension structures are adopted. In receiving the necessary areas of cables, the load of the reinforced ribs is not included, the larger cross-section is accepted in the computations Ac = 63, 02 cm2.

5 mm Galwanized wires

Covering pipe from HDPE

Figure 2.30 Exemplary cable’s cross-section

The second ties’ group that connect the pylon and arches is less strenuous than the main cables, therefore the solid bar with 36mm diameter is adopted to the computation , Ac2 = 10, 18 cm2. According to [7], the Young’h modulus E = 210GPa for these elements is implied.

An Example of Deterministic Analysis of Cable-Stayed Bridges • 51