• Nie Znaleziono Wyników

An experiment with continuous-pulsed excitation of a conventional low-power CO₂ gas laser

N/A
N/A
Protected

Academic year: 2021

Share "An experiment with continuous-pulsed excitation of a conventional low-power CO₂ gas laser"

Copied!
10
0
0

Pełen tekst

(1)

An experiment with continuous-pulsed excitation

o f a conventional low-power COa gas laser

"Wo jc ie c h Mic h a l s k i

Institute of Telecommunication and Acoustics, Technical University of W rocław , W ybrzeże W yspiańskiego 27, 50-370 W roclaw , Poland.

Operation of a conventional C 0 2 gas laser in discharge conditions when current pulses are superimposed on arbitrary value of DC discharge current has been described. This type o f supply has been named continuous-pulsed (CP) excitation. The properties o f the same C 0 2 gas laser at the CP excitation and at the “ pure” CW one have been also compared. A t the continuous-pulsed excitation the mean value of the output increased m ore than two times com pared to the CW output power.

1 . Introduction

A conventional C 0 2 gas laser can operate both in the regime of the direct current excitation and in conditions of excitation by pulses of arbitrary length and repetition rate. In the latter case considerable increase of the output power can be obtained in comparison to the OW operation [1, 2]. Certain modification of both the types of supply is the excitation called here the continuous-pulsed (CP) one. The essence of the CP excitation lies in formation of current pulses in supply circuit of a conventional C 0 2 gas laser. These pulses are superimposed on an arbitrary value of DC current. This optionally fixed value of DC current determines initial discharge conditions at the given total gas pressure. At the CP excitation the output power, instead of being continuous, is in the form of pulses imposed on a CW output power level. This level is defined by fixed initial discharge conditions, it is by the DC current and total gas pressure in discharge tube. The continuous-pulsed excitation differs from that described in papers [3-10], where current pulses started from zero-amper level, i.e., from the level at which discharge was switched off.

An experiment with the CP excitation of a C 0 2 laser will be described be­ low . The purpose of the experiment was to study the properties of a C 0 2 gas

(2)

358 W . Michalski laser in a wide range of the plasma discharge parameters, for various pulsing parameters. A comparison of properties of the same C 0 2 laser at the CP excita­ tion and the CW one is also given. A wide discussion of the obtained results- connected with the analysis of the phenomena occurring in a C 02-mix discharge plasma during the CP excitation will be given in the subsequent paper.

2 . Description of experiment

2*1. Construction o f the C 02 laser

A two-sectional C 0 2-mixture gas laser was used in the experiment. Brewster- angle water-cooled discharge tube had 14 mm in diameter and 1.2 m in length. The windows were made of polished sodium chloride crystal. The laser inter­ ferometer consisted of a pair of gold coated mirrors. One of them, a 10 m curved mirror, had a 3 mm hole output power coupling and was mounted on a piezo­ ceramic driver for a precise adjustment of the laser cavity. Diameter of the hole was optimum for the CW work of the C 0 2 gas laser. The other one was flak and had zero transmission. The total length of the interferometer was 1.8 m. Power supply system of the C 0 2 laser is presented in Pig. 1. A high voltage

Fig. 1. Supply circuit o f the C 0 2 laser. 1 - high voltage power supply, 2 - discharge current stabilizer, 3 - DC supply of piezoceramic driver, 4 - P Z T driver

power supply was used for the excitation of the gases in the tube equipped with three electrodes, the central one being the anode (A) and the other two - the cathodes (C). The electric current capacity of this power supply was 100 mA and the voltage was varied from zero to 10 kV. The electrical supply circuits of both the sections contained independent discharge | current stabilizers. Dynamic impedance of each of the current stabilizers approached 10 MO.

(3)

2 .2 . Experim ental procedure

In order to obtain the CP operation of the C 0 2 gas laser the current pulses of rectangular shape were formed in the supply circuit of each of the tube sec­ tion. These pulses were shaped by means of the stabilizers to which a square wave generator was connected. The possibility of such an additional use of the current stabilizers was checked in auxiliary circuit in which, instead of each of the tube sections, a passive impedance was included. Oscilloscopic observations of the current pulses were made at various DC currents at the amplitude of the pulses ranging within 0-40 m l . When repetition frequency of the pulses ranged from 30 Hz to 20 kHz that the observed current pulses had a rectangular waveform.

Fig. 2. Block-diagram of the measuring system. 1 - high voltage power supply, 2 - current stabilizer identical for both sections, 3 - square-wave generator, 4 - lock-in nanovoltm eter for measurements o f current pulse amplitude, 5 - mechanical chopper, 6 - lamp for reference beam, 7 - visible light detector, 8 - (Hg, Cd)Te detector, 9 - lock-in nanovoltmeter for measu­ rements o f the output power level P 0 (switch S in position 2) as well as output peak power P p (swith S in position 1), 10 - dual-beam oscilloscope

The CP operation of the C 0 2 laser has been studied in a measuring system of the block-diagram which is presented in Fig. 2. For each fixed value of total gas pressure and each value of DC current, three quantities were measured, namely:

— output light DC component, P 0, — amplitude of the current pulses, Ip,

— amplitude of the output pulses, P p, corresponding to the given amplitudo of the current pulses I p.

(4)

360 W . Michalski These measurements were made according to the following procedure. First­ ly, the glow discharge was switched-on at optional fixed mix pressure in the laser tube and desirable, the same in both the tube sections, value of DO current was fixed. Next, a mechanical chopper of the laser beam was switched-on and the output power level P 0 was measured in arbitrary units. Subsequently, the mechanical choppering was turned-off and the current pulses with different amplitudes were overlapped on the fixed value of DC current. In both the tube sections the amplitudes of the pulses were the same. Last of all, the dependence of the P p on the I p was measured. The above procedure was repeated for various initial discharge parameters, it is, for different mix pressures and DC currents. Eepetition rate of the current pulses in these measurements was the same and equalled 200 Hz (see explanation in Sec. 2.3). The amplitude of the pulses was changed from zero to 30 mA.

The measurements of the P 0, I p, and P p quantities have been based on phase sensitive detection technique which made it precise and independent of the chan­ ges of infrared detector parameters with temperature. The possibility of the use of such a technique results from the fact that all three types of pulses, the amplitudes of which have been subjected to measurements, were of rectangular waveform. Therefore, their amplitudes could be calculated by measuring rms of the first harmonic component.

All the measurements have been made for gas mixture composition C 02 : N 2 : He = 1 :1 : 4 in no-flow conditions. This species composition was opti­ mum for the C'W work of the C 0 2 gas laser. Total mix pressure was changed within 8-16 hPa, whereas the values of DC current were changed from 2 to 25 mA.

2 .3 . Auxiliary measurements

As a result of auxiliary measurements two different problems have been solved: pressure-current conditions for the CW operation of the C 0 2 laser and optimum repetition frequencies of the current pulses. The CW-conditions have been defi­ ned by measuiing of the output power P 0, for different total gas pressures and various DC currents. During the measurements the laser cavity was precisely adjusted by means of the piezoceramic driver. The obtained results are presented in Fig. 3 as dependence of P 0 on DC current at various mix pressures as a para­ meter. Best conditions for the CW operation have been found for total pressure of about 13.3 hPa and for DC current in each of the tube sections equal to 10 mA.

A range of repetition frequencies of the current pulses in which the output pulses were of rectangular waveform and had extreme peak power has been determined by the auxiliary measurements. These measurements have confirm­ ed that both the requirements are fulfilled within the frequency range of 150-250 Hz. Below the frequency of 150 Hz and also above the frequency of 250 Hz the rectangular shape of the output pulses was strongly distorted.

(5)

Additionally, above 250 Hz the output peak power decreased fast. For the above reasons further studies have been performed at the frequency of 200 Hz. Duration of the current pulses was one half of the period, it is 2.5 ms.

3 . Experimental results

Initial observations and measurements of the CP operation of the C 0 2 laser have yielded two interesting results. Firstly, above the optimum 10-15 mA range of DC currents the output power P 0 decreases and so does the output peak power P p. Furthermore, amplitude of these pulses is strongly unstable. Secondly, at mix pressure greater than 16 hPa, a stable CP operation of the C 02 laser was possible only at continuous and precise manual adjustment of the laser cavity by means of the piezoceramic driver. That is why the detailed studies performed in mix pressure ranging within 8-16 hPa, were confined to DC currents lower than or at most equal to the optimum values of DC current. The amplitude of the current pulses was changed from zero to the maximum value of 30 mA.

In accordance with the experimental procedure described in Sec. 2.2, the amplitude variations of the output pulses vs. the amplitude of the current pulses have been measured for different mix pressures as well as initial DC currents. The obtained results are shown in Figs. 4-7 for the pressures of 8, 10.7, 13.3, and 16 hPa, respectively, where different values of DC current are the parameter and the output peak power P p is given in arbitrary units.

A few interesting properties of the C 0 2 laser with the CP excitation result from the experimental data. Irrespective of the total pressures fixed in the discharge tube, the output peak power P p increases initially with the current amplitude I p. The output peak power ceases to increase when a certain value

0 5 10 15 20 25

I0 [mA]

Fig. 3. Output power level P 0 against the DC current I 0 for different total gas m ixture pressures

(6)

362 W . Michalski of the 7p is exceeded, and in some cases it even drops when the I p further in­ creases. As a rule, at the same amplitude of the current pulses, the reference DC current is the greater the smaller is the amplitude of the output pulses. Moreover, monotonic increase of the output peak power can be observed when gas pressure

grows.

Fig. 4. Output peak pow er P p vs. the current pulse am plitude Jp for a few values o f the DC current Z0 at total gas pressure of 8 hP a

4 . Continuous-pulsed and C W excitation

Certain comparison of the output parameters of the C 0 2 gas laser at the CP and CW excitations can be based on the results presented above. It is of particular interest for farther interpretation of the experimental results. As to the CP excitation this comparison can concern both the output peak power P p and the mean value of the output power, called P m. Taking into account that the output

(7)

pulses were of rectangular waveform, the values of the P m can be easily calculat- id from formula P m = P 0 + 0.5 Pp. It is evident that the optimal values of the P„, P p and P m occur at various discharge parameters. The Table includes optimal values of these three parameters of the output calculated for the four total pressures.

The maximum values of the output peak power exceed the maximum level jf the P 0 from about two times at the pressure of 16 hPa to four times at the pressure of 8 hPa. The maximum of the mean output power P m, however,

Fig. 6. Same as Fig. 4 at total gas pressure o f 13.3 hPa

Fig. 7. Same as Fig. 5 at total gas pressure og 16 hPa

(8)

364 W . Michalski Comparison o f optim al values o f the output power P 0 at the CW excitation with the output peak power P p and the mean values o f output P m at the CP excitation for various total gas pressures

Total gas pressure

[hPa] 8.0 10.6 13.3 16.0

Optimum discharge current

CW excitation [m A ] 8.0 12.5 10.0 12.0

M axim um output power P 0

(arb. unit) 2.1 4.63 5.7 5.4

Parameters o f excitation I 0 = 2 m A = 5 m A = 4 m A = 5 m A <o

co Optimum values l p = 18 m A = 24 m A = 27 m A = 25 m A

P. g of the P p Maximum output peak

•H

CO - g power (arh. unit) 8.65 8.8 12.0 12.0

I

· - Parameters o f excitation I 0 = 5 m A = 10 m A = 4 m A = 10 m A

e M Optimum mean I p = 18 m A = 21 mA = 28 m A = 22 m A

Ö

o power Maximum values of the

o P m (arh. unit) 4.5 7.7 10.0 10.8

exceeds the maximum output power P 0 from about 1.7 times at the pressure of 10.6 hPa to about 2.2 times at the pressure of 8 hPa.

It is interesting to compare optional mean value of the output power P m (measured at given DO current I 0 and at arbitrary value of the current pulse amplitude I p) with the output power P 0, for DC current (I0 + I B)· The correspond­ ing dependences calculated from the experimental data have been illustrated in Pig. 8.

Fig. 8. Comparison o f the mean output power Pm at the CP excitation (continuous line) with the output power P 0 at the CW one (dotted line) at various total pressures: · - 8 hPa, A - 10.6 hPa, x - 13.3 hPa, o - 16 hPa, and initial DC currents (at the CP excitation ): 5 m A, 10, m A, 4 m A , 10 m A, respectively

(9)

It is very characteristic that the mean values of the output at the OP exci­ tation always exceed the output power P 0 at the CW excitation, provided that the comparison concerns the same total pressure.

5 . Conclusions

The presented experiment is interesting for two reasons. Firstly, it shows that the output power of a conventional C 02 gas laser can be increased in a simple and cheap manner. Using the CP excitation and appropriately choosing the initial discharge condition (i.e., total pressure and DC current) as well as pulsing parameters (i.e., repetition rate of the current pulses and their amplitude) the mean output power can be considerably increased, in particular, above twofold increase of the output has been measured in the presented experiment. Secondly, this experiment is of importance for studies of some processes in the COa-mix discharge plasma (see next paper).

Certain part of the experimental results can be elucidated with a relative ease. Thus (see Figs. 4-7), the observed variations of the P p vs. the / p can be simply explained. When there occurs any current pulse, then the electron concentration grows in volume of the discharge and, consequently, electron impact excitation of the C 0 2 molecules on the upper laser level increases consi­ derably. It explains initial, often linear, increase of the P p vs. the Jp. Farther growth of the I p causes more slower and slower increase of the P p. The maxima or “ saturation effects” observed in these dependences can be explained by the growing influence of the electrons on the life time of the CO2(00°l) level. Ch i n h

Da n g et al. [11] have ascertained recently that electron deexcitation makes

a substantial contribution to the relaxation rate of the CO2(00°l) and dominates other relaxation processes at high current. The fall of the P p with increase of the initial DC current, observed at the given total pressure, can be explained by the growth of the gas temperature and as a consequence by the decrease of the lifetime of the (00°l)CO2.

The answers to the questions why the output pulses were of rectangular shape only within the frequency range of 150-250 Hz, as well as why the mean output power P m at the CP excitation always exceeded the level of the output power at the CW excitation (see Fig. 8) are much more complicated. Wide ex­ planation of these two facts, based on analysis of time-dependence of the gas temperature and on C 0 2 dissociation kinetics, has been given in subsequent

paper.

References

[1] Cl a r k P . 0 ., Sm it h M. R ., A ppl. Phys. L ett. 9 (1966), 369.

[2] Bi r y u k o v A . S., Go r d ie t z B. F ., Sh e l e p in L . A ., Zh. Eksp. Teor. Fiz. (USSR) 57 (1969), 585.

[3] Ty t e D. C., A dv . Quant. Electron 1 (1970), 129. [4] McKn ig h t W . B ., J. A ppl. Phys. 40 (1969), 2810.

(10)

366 W . Michalski [5] Le v in s o nG. R ., Sv ir id o vA . N., Ty c h in s k iiV. P ., Fr o l o v aV. G., Zh. Prikl. Spektrosk.

(USSR) 10 (1969), 425.

[6] Cr a f e r R . C., Gib s o nA . F ., Ke n tM. J., Kim m it t M. F., Brit. J. Appl. Phys. (J. P hys. D) 2 (1969), 183.

£7] Bo o th D . J ., Sm it h A . L . S., P hys. L ett. 31A (1970), 241.

£8] Ka r l o v N . Y ., Ko n e v Yu. B., Ko o zm in G. P ., Pr o k h o r o v A . M., IE E E J. Quant.

Electron. Q E -5 (1969), 137.

[9] Da y G. W ., Ga d d y O. L ., Ju n g l in g K . C., IE E E J. Quant. Electron. QE-5 (1969), 423. £10] Sm it hA . L . S., Au st in J. M., J. Phys. D : A ppl. Phys. 7 (1974), 314.

£11] Ch in h Da n g, Re id J ., Ga r s id e B . K ., IE E E J. Quant. Electron. QE-19 (1983), 755.

Received February 14, 1985, in revised form June 10, 1985

Эксперимент со стационарно-импульсным возбуждением разрядного С 0 2 лазера Описана работа С 0 2 лазера в условиях возбуждения, когда на стационарный ток разряда наложены токовые импульсы. Этот род возбуждения назван стационарно-импульсным (С-И). Сравнены свой­ ства С 0 2 лазера при С-И возбуждении и стационарном возбуждении. Средняя мощность излучения при С-И возбуждении всегда превышает выходную мощность при чисто стационарном возбуждении, максимально в два раза.

Cytaty

Powiązane dokumenty

Another way of operating a spark at a moderately low voltage, typically a few kV compared with the 60 kV which is necessary in an average high voltage high vacuum

High-speed rail and extended inter-modality can improve the regional and local public transportation system, which can be a frame for high quality, sustainable urban development..

Thus, two images of particles distribution on the surface acquired at the investigated test parameters in some time interval  t provides an information allowing

Но так как в последнее время (nouissimo tempore) придет и вечное воздаяние святым и наказание нечестивым, то им велено ждать» 79. 877;

Nieustannie pragnął się uczyć nowości, a jeśli nawet sam nie podejmował się tego trudu, z wypiekami na twarzy słuchał swoich fachowców, którzy zaznajamiali go z

[r]

The allomorphy in the plural morpheme of Old English disyllabic neuter a- stems which is revealed in the corpus texts is characterized by (1) unfailing regular vocalic-plural