SDRIVE 100 Series, most compact drive, with exclusive joystick parameter setting system, for A.C. 230V II motor control.

ELECTRICAL SPECIFICATIONS

SDRIVE

VARIABLE SPEED DRIVE

100 Series

Voltage supply 200 to 230V/AC ±10 single phase

0,4KW - 2,2KW.

Input frequency 50 - 60 Hz. ±5%

Input power factor > 0,98 (over fundamental frequency) Momentary power loss < 15 mS (continuous operation).

> 15 mS (autoreset).

Motor output voltage 0 to input voltage

Current overload capacity 150% during 60sec.

200% during 1 sec.

Frequency range 0 to ±400Hz

Efficiency (full load) > 98%

Modulation method Vector space modulation

Modulation frequency 15 kHz maximum

Degree of protection IP20

Operation temperature -10ºC to 50°C

Storage temperature -20ºC to +65°C

Relative humidity < 90%, no condensation

Altitude 1000m

Altitude loss factor (>1000m) -1% per 100m; max. 3000m.

Vibration Max. 5.9m/sec2 (0.6G)

Application site Protected from corrosive gas, combustible gas, oil mist or dust.

Drive trip Over-voltage.

Under-voltage.

Over-current.

Ground fault current detection.

Over-temperature of inverter and motor.

Output phase open.

Overload.

Communication error.

Loss of frequency command.

H / W fault.

Alarm condition Stall prevention

Overload

Control method V /Hz, Vector sensorless

Analogue inputs 1 input 0 - 10Vcc and 1 input 0- 20mA

Digital inputs 5 multifunction inputs

Analogue outputs 1 output 0 - 10V

Digital output 1 multifunction output, open collector.

Relay output 1 fault relay 2A 30Vdc 0.5A 125Vac

Communications port RS485 and Modbus RTU protocol (as accesory) Operation features PID control, 3-wire, up-down operation.

Standards CE, ISO9001and ISO14000

(2)

DIMMENSIONS AND STANDARD RATINGS

REFERENCE I (A) KW HP V SD1103 3 0,55 0,75 230II SD1103F 3 0,55 0,75 230II

SD1105 5 1,1 1,5 230II

SD1105F 5 1,1 1,5 230II

SD1108 8 2,2 3 230II

SD1108F 8 2,2 3 230II

SD1112 12 3 4 230II

SD1112F 12 3 4 230II

* Filters RFI industrial environmental.

REFERENCE Dimmensions H W D

SD1103 79 143 143 0.87

SD1103F 79 143 143 0.95

SD1105 79 143 143 0.89

SD1105F 79 143 143 0.97 SD1108 156 143 143 1.79 SD1108F 156 143 143 1.94 SD1112 156 143 143 1.85

SD1112F 156 143 143 2

Weight (Kg)

P4 P5 VR V1 C M I AM

MOEXTGP24 P1 P2 CM P3 30A 30B 30C

NP N

P NP

L 1 N + + 1 _

U V W

min m ax

RUN STOP /RST

FWD RE V

SDRIVE

V AR IA BL E S P EE D DR IVE 100 S er i es

79

m in m a x

R U N S T O P /R S T

F WD R E V

WARNING

SDRIV E

VA RI AB LE SP EE D DR IV E 1 0 0 S e r i es

WARNING

1 56

min max

RUN STOP/RST

FWDREV

143

SDRIVE

VARIABLE SPEED DRIVE 100 Series

CONTROL AND POWER WIRING

POWER ELECTRONICS DEUTSCHLAND Gmbh

Co nr a dtystr a sse, 41 · 9 04 41 · N ÜRNBE RG · DE UTS CHLA ND · Tel . ( +49 ) 911 99 4 3 99 0 · Fax . (+4 9) 9 11 9 9 43 9 99 · www.p ed -g mb h.d e POWER ELECTRONICS E SPAÑA

Leonardo da Vinci, 24-26 · Parque Tecnológico · 46980 · PATERNA · VALENCIA · ESPAÑA · Tel. (+34) 96 136 65 57 · Fax. (+34) 96 131 82 01 · www.power-electronics.com L1

N + +1 _

U V W G AM CM MO

EXT G

3 0A 3 0B 30C P1 P2 P3 P4 P5 P 24

VR V1 I CM

0-10V Multi-funct ion analog output terminal 0V common terminal for AM t erminal

Multi-function open collector output ??24Vdc 50mA.

Ground T/ M for MO O pen Clos ed

30A and 30B common Fault Relay

2A 30 Vdc 0.5A 125Vac Mult ifunction input t erminal

FX: Forward run RX: Reverse run BX: Emergency st op JO G: J OG operat ion RST: Fault Reset 24V power for P1 - P5

12V power supply for potent iomet er 10mA 0-10V Analog input terminal

0-20mA Analog input t erminal 0V common terminal for P1-P5, AM, P24 10K

AC line voltage input

Terminal for inverter DC P/S

Motor Motor

G round

+ +1 U V W Filter EMI

Class B 200 - 230V

L1

N

_

Cytaty

Powiązane dokumenty

current The inverter turns off its output when a ground fault occurs and the ground fault current is more than the internal setting value of the inverter.. I OL

The protection will be enabled if the current is below the value adjusted in this parameter when the operating frequency is twice the motor rated slip speed.. The protection will be

F61 NO INPUT V This fault will be shown in the display of the SD700 when the start command is activated and the input voltage applied to the drive is lost, and the drive is powered

Drive will trip (it turns off the output to the motor) because of fault ‘F13 HI V IN’ when average voltage, measured at the input of the equipment, is higher than the value set

Although the control board is insulated galvanically, for safety reasons it is recommended not to modify the wiring while the equipment is connected to the input power

Abstract—Cyberphysical systems, with their interdependence between physical behaviour and digital control, need insights from frequency domain control engineering, state space

Urządzenia Sentera wymieniają informacje za pośrednictwem sieci o nazwie Modbus RTU.. Modbus to szeregowy protokół komunikacyjny opracowany przez Modicon® w 1979

W oknie konfiguracji sprzętu „Project tree” w PLC_2[CPU 1214 DC/DC/DC] należy rozwinąć zakładkę Program blocks i dwukrotnie kliknąć lewym przyciskiem myszy na zakładkę