Optimal drug-eluting stent implantation with the aid of optical coherence tomography in the stenotic lesion of ectatic coronary artery

N/A
N/A
Protected

Academic year: 2022

Share "Optimal drug-eluting stent implantation with the aid of optical coherence tomography in the stenotic lesion of ectatic coronary artery"

Copied!
2
0
0

Pełen tekst

(1)

Address for correspondence: Myung Ho Jeong, MD, Cardiovascular Convergence Research Center of Chonnam National University Hospital, Gwangju 501-757, Republic of Korea, tel: 82-62-220-6243, fax: 82-62-228-7174, e-mail: myungho@chollian.net

Received: 24.11.2017 Accepted: 25.12.2017

INTERVENTIONAL CARDIOLOGY

Cardiology Journal 2018, Vol. 25, No. 4, 534–535

DOI: 10.5603/CJ.2018.0085 Copyright © 2018 Via Medica

ISSN 1897–5593

534 www.cardiologyjournal.org

IMAGE IN CARDIOVASCULAR MEDICINE

Optimal drug-eluting stent implantation with the aid of optical coherence tomography in the stenotic lesion of ectatic coronary artery

Yongcheol Kim, Myung Ho Jeong, Min Chul Kim, Doo Sun Sim, Young Joon Hong, Ju Han Kim, Youngkeun Ahn

Division of Cardiology, Chonnam National University Hospital, Gwangju, Korea

A 59-year-old man presented with 1 day his- tory of intermittent angina and an elevated high sensitivity troponin measurement. He had received stent implantation with a 4.5 × 16 mm bare metal stent (BMS) at the proximal portion of the ectatic right coronary artery (RCA) 3 years prior to this.

Urgent coronary angiography (CAG) demonstrated the severe stenosis in the distal RCA with patent of implanted BMS (Fig. 1A). The selection of ap- propriate stent size and stent optimization to avoid under-expansion and malapposition due to the stenotic lesion of ectatic RCA led to an assessment with optical coherence tomography (OCT). OCT (Suppl. Video 1) demonstrated that distal reference lumen and external elastic lamina (EEL) diameter of 4.67 mm and 5.20 mm, respectively (Fig. 1B). OCT also showed a minimal lumen area of 3.32 mm2 (Fig. 1C) and proximal reference lumen and EEL diameter of

3.91 mm and 4.65 mm, respectively (Fig. 1D). The OCT assessment led to predilation with a 3.0 ×

× 15 mm balloon, and a 4.0 × 24 mm bioabsorbable polymer everolimus-eluting stent (SYNERGYTM, Boston Scientific, USA) implantation at 16 atmos- phere. Postdilation was achieved with a 5.0 × 12 mm noncompliant balloon at up to 18 atmosphere in the distal portion of implanted drug eluting stent (DES).

Repeated OCT assessment demonstrated (Suppl.

Video 2) a minimal stent area of 11.92 mm2 (Fig. 1E), excellent stent expansion, and good strut apposition without edge dissection. Final CAG showed good distal flow without residual stenosis (Fig. 1F).

Percutaneous coronary intervention with DES for ectatic coronary artery is challenging due to stent optimization. This case highlights the im- portant role OCT plays in the stent optimization for ectatic vessel.

Conflict of interest: None declared

(2)

Figure 1. A. Angiographic assessment demonstrating severe stenosis in the distal right coronary artery (RCA) with ectasia and patent bare metal stent (BMS) in the proximal RCA (white arrow); B. Optical coherence tomography (OCT) assessment demonstrating distal reference lumen diameter of 4.67 mm and external elastic lamina (EEL) diameter of 5.20 mm; C. OCT cross-section demonstrating minimal lumen area (MLA) of 3.32 mm2; D. OCT demonstrating proximal reference lumen and EEL diameter of 3.91 mm and 4.65 mm, respectively; E. OCT demonstrating minimal stent area (MSA) of 11.92 mm2 and good stent apposition; F. Final angiogram demonstrating good distal flow without residual stenosis from treatment with 4.0 × 24 mm SYNERGYTM stent.

www.cardiologyjournal.org 535

Yongcheol Kim et al., OCT-guided PCI for ectatic vessel

Cytaty

Powiązane dokumenty

Methods: Twenty-two 7-month-old male farm pigs underwent implantation of two steel stents, one short (8 mm length) and one long (16 mm length), in the right coronary artery. The

ing catheter with side holes, the right coronary artery intravascular ultrasound confirmed an underexpanded stent with heavy circumfer‑.. ential calcification and IVL treatment

We performed a serial, very long-term three- and nine-year optical coherence to- mography evaluation of neoatherosclerotic progression after sirolimus- and paclitaxel-eluting

We provided evidence that DES implantation was suc- cessfully performed for the treatment of SCA reocclusion after BMS implantation, and the vessel patency was maintained with

According to our findings and previous studies, we suggest that adequate lesion preparation, higher pressure or longer bal- loon inflation time, and adjuvant postdilatation may

We present a case of an asymptomatic migration of a bare metal stent (BMS) from the left main coronary artery (LMCA) to the right internal carotid artery (RICA), treated with

Gonenc Kocabay, MD, Department of Cardiology, Kartal Kosuyolu Heart and Research Hospital, Istanbul, Turkey, tel: +90 0532 518 00 35, telefax: +90 0216 459 63 21,

The aim of our study was to compare in a randomised study the deliverability of bare metal stents (BMS) and stents covered with a drug eluting polymer (DES), based on identical