• Nie Znaleziono Wyników

Transcatheter aortic valve implantation: the role of transcranial Doppler monitoring

N/A
N/A
Protected

Academic year: 2022

Share "Transcatheter aortic valve implantation: the role of transcranial Doppler monitoring"

Copied!
1
0
0

Pełen tekst

(1)

www.kardiologiapolska.pl

Kardiologia Polska 2014; 72, 4: 392; DOI: 10.5603/KP.2014.0081 ISSN 0022–9032

Studium przypadku / CliniCal Vignette

Transcatheter aortic valve implantation:

the role of transcranial Doppler monitoring

Przezcewnikowa implantacja zastawki aortalnej: rola monitorowania doplerem przezczaszkowym

Zenon Huczek

1

, Piotr Szczudlik

2

, Janusz Kochman

1

, Anna Kamińska

2

, Grzegorz Opolski

1

11st Department of Cardiology, Medical University of Warsaw, Warsaw, Poland

2Department of Neurology, Medical University of Warsaw, Warsaw, Poland

Transcatheter aortic valve implantation (TAVI) is an effective treatment option of severe aortic stenosis (AS) in inoperable and high-risk patients. However, the use of large-bore delivery catheters and the presence of diffuse atherosclerosis in the aortic arch, as well as calcifications of the aortic annulus, may pose a substantial risk of ischaemic stroke during bal- loon predilatation, bioprosthesis delivery and deployment. Transcranial Doppler (TCD) monitoring is a well established method of detecting cerebral embolic load during invasive procedures. We present three patients who underwent TAVI from transfemoral, transaortic and transapical access. During the entire procedure, patients were monitored with TCD and the results were analysed by an experienced neurologist. Patient no. 1: 67-year-old male with AS (ejection fraction [EF] 40%, mean pressure gradient [PG] 45 mm Hg, aortic valve area [AVA] 0.6 cm2) with severe chronic obstructive pul- monary disease and logistic Euroscore of 11.1%. Self-expandable 29 mm Corevalve was implanted via transfemoral route with two post-dilatations. TCD monitoring lasted for 135 min and consisted of 111 high intensity transient signals (HITS) most of which occurred during deployment of the device (Fig. 1). Patient no. 2: 63-year-old patient with AS (EF 65%, mean PG 80 mm Hg, AVA 0.73 cm2) and recent history of lymphoma accompanied by chronic severe anaemia (logistic Euroscore of 5%). Self-expandable 26 mm Corevalve was implanted via direct transaortic access (hemisternotomy). TCD monitoring lasted for 80 min and consisted of 134 HITS. The majority of signals occured during deployment of the device (Fig. 2). Patient no. 3: 76-year-old male with AS (EF 65%, mean PG 40 mm Hg, AVA 0.66 cm2) with porcelain aorta and logistic Euroscore of 19.9%. The patient underwent successful implantation of 26 mm self-expandable Engager valve via transapical route. TCD during 104 min revealed 294 HITS. Ischaemic stroke or transient ischaemic attack (TIA) is reported in approximately 5% of cases after TAVI and is associated with poor clinical prognosis. According to the PARTNER trial, although equal in longer-term observation, stroke and TIA occur significantly more frequently in the perioperative period after TAVI than after conventional surgery. Recent studies with vascular filters have proved that embolic debris consists of aortic wall, valve and collagenous tissue as well as thrombus. However, data from pilot studies with cerebral embolic protection devices (deflectors and filters) shows that these devices reduce only the total volume of new cerebral lesions, but not the proportion of patients with new lesions or the number of new lesions. Therefore, prospective studies with TCD and diffusion-weighted magnetic resonance imaging investigating the impact of different delivery routes and procoagulant status (e.g. platelet reactivity) on cerebrovascular events and silent ischaemia are warranted.

Address for correspondence:

Zenon Huczek, MD, PhD, 1st Chair and Department of Cardiology, Medical University of Warsaw, ul. Banacha 1A, 02–097 Warszawa, Poland, e-mail: zenon.huczek@wum.edu.pl

Conflict of interest: none declared

Figure 2. Multiple high intensity signals (HITS) obtained during transcranial Doppler (TCD) monitoring (red arrows)

Figure 1. Single high intensity signal (HITS) obtained du- ring transcranial Doppler (TCD) monitoring (red arrow)

Cytaty

Powiązane dokumenty

figure 1 A – multislice contrast computed tomography of implanted bioprosthesis and the ascending aorta, the short axis view; B – multislice contrast computed tomography of

Figure 2 Postoperative outcomes of transcarotid and transfemoral transcatheter aortic valve implantation compared between the study groups and with the preoperative values: a –

ence of >48° angle between the aortic annulus Transcatheter aortic valve implantation (TAVI)4. is a well ‑established modern treatment of severe symptomatic

However, a higher risk of THVT may be expected in patients with chronic obstructive pulmonary disease, a smaller aortic valve area, a higher mean postprocedural

Early regression of left ventricular mass associated with diastolic improvement after transcatheter aortic valve implantation.. Levy D, Garrison RJ, Savage DD, Kannel WB,

Background: Transaortic (TAo) transcatheter aortic valve implantation (TAVI) is an alter- native approach in patients considered to be at high risk for classical open surgery with poor

Transcatheter aortic valve implantation for the treatment of severe symptomatic aor- tic stenosis in patients at very high or prohibitive surgical risk:.. Acute and late outcomes of

The images show high-intensity transient sig- nals (HITS) just below the aortic valve in both par- asternal and apical long axis views.. The valve re- placement otherwise