• Nie Znaleziono Wyników

Transcatheter mitral valve replacement with Tendyne™Device: overview of three-dimensional echocardiography monitoring

N/A
N/A
Protected

Academic year: 2022

Share "Transcatheter mitral valve replacement with Tendyne™Device: overview of three-dimensional echocardiography monitoring"

Copied!
2
0
0

Pełen tekst

(1)

1161 w w w . j o u r n a l s . v i a m e d i c a . p l / k a r d i o l o g i a _ p o l s k a

Correspondence to:

Giordano Zampi, MD, Department of Cardiology, Belcolle Hospital, Strada Sammartinese s.n.c., 01100, Viterbo, Italy phone:

+39 0761 339 435/278, e-mail:

giordano.zampi@alice.it Copyright by the Author(s), 2021

Kardiol Pol. 2021;

79 (10): 1161–1162;

DOI: 10.33963/KP.a2021.0080 Received:

June 16, 2021 Revision accepted:

August 4, 2021 Published online:

August 4, 2021

„ C L I N I C A L V I G N E T T E

Transcatheter mitral valve replacement

with Tendyne™ Device: overview of three-dimensional echocardiography monitoring

Vincenzo Polizzi

1

, Amedeo Pergolini

1

, Giordano Zampi

2

, Giulio Cacioli

1

, Daniele Pontillo

3

, Francesco Musumeci

1

1Department of Cardiovascular Science “S. Camillo-Forlanini” Hospital, Rome, Italy

2Department of Cardiology, Belcolle Hospital, Viterbo, Italy

3Cardiac Intensive Care Unit, Belcolle Hospital, Viterbo, Italy

A 77-year-old Caucasian male with post-is- chemic dilated cardiomyopathy was referred to our Emergency Department with recurrent acute pulmonary edema. He reported multiple previous hospitalizations for heart failure de- spite maximal tolerated medical therapy.

Echocardiography showed a dilated left ventricle with systolic dysfunction and severe secondary mitral regurgitation (left ventricular end diastolic volume of 135 ml/m

2

; ejection fraction of 25%; effective regurgitant orifice area of 0.42 cm

2

; regurgitant fraction of 53%).

These features, together with the above-men- tioned clinical history, posed a very high surgical risk to the patient in the absence of feasibility criteria for a percutaneous edge-to- edge mitral valve repair (“proportionate” mitral valve regurgitation with inadequate coaptation length, borderline valve area). Therefore, our local Heart Team suggested the procedure of a transcatheter mitral valve replacement as an alternative therapeutic option [1].

The Tendyne Mitral Valve System (Tendyne Holdings, LLC, a subsidiary of Abbott Vascu- lar, Roseville, MN, USA) consists of a delivery system, an 18 G needle; a 36 French sheath and a D- shaped tri-leaflet porcine pericar- dial valve, supported by a synthetic circular inner frame. The replacement procedure is performed by a trans-apical approach. An alternative hybrid technique for transcatheter mitral valve replacement has been previously adopted with success in a different high-risk setting, such as infective endocarditis in pedi- atric patients [2].

In this surgical setting, echocardiography plays a paramount role both in procedure plan- ning and intra-operative monitoring. Initially, after having identified the thoracic access, the sheath is inserted rigorously orthogonally to the mitral annulus plane (Figure 1A). Subse- quently, the sheath is advanced and stopped 1 cm above the mitral annulus (Figure 1B), and the valve is finally deployed (Figure 1C–D).

Postprocedural transesophageal echocardi- ography showed correct valve seating with no residual motion of the prosthesis and no left ven- tricular outflow tract obstruction (Figure 1E–F).

This case underscores the paramount rele- vance of 3D echocardiographic monitoring in interventional cardiology in order to achieve the most favorable procedural outcomes.

Article information

Acknowledgments: IRB approval, consent statement and clinical trial registration are not applicable for this study.

Data sharing is not applicable to this article as no new data were created or analyzed in this study.

Conflict of interest: None declared.

Open access: This article is available in open access un- der Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with oth- ers as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially. For commercial use, please con- tact the journal office at kardiologiapolska@ptkardio.pl.

How to cite: Polizzi V, Pergolini A, Zampi G, et al. Tran- scatheter mitral valve replacement with Tendyne™De- vice: overview of three-dimensional echocardiography monitoring. Kardiol Pol. 2021; 79(10): 1161–1162, doi:

10.33963/KP.a2021.0080.

(2)

1162

K A R D I O L O G I A P O L S K A , 2 0 2 1 ; 7 9 ( 1 0 )

w w w . j o u r n a l s . v i a m e d i c a . p l / k a r d i o l o g i a _ p o l s k a

REFERENCES

1. Muller DWM, Farivar RS, Jansz P, et al. Tendyne Global Feasibility Trial Investigators. Transcatheter mitral valve replacement for patients with symptomatic mitral regurgitation: a global feasibility trial. J Am Coll Cardiol. 2017; 69(4): 381–391, doi: 10.1016/j.jacc.2016.10.068, indexed in Pubmed: 28040318.

Figure 1. A. Transesophageal echocardiography, biplanar imaging, obtained from inter commissural view showing the Tendyne valve partially deployed within the mitral annulus. B. 3D transesophageal echocardiography surgeon’s view, showing sheath positioning (asterisk showing the part facing LVOT; circle showing the D-shape of the valve). C. 3D transesophageal echocardiography en face (surgeon’s view).

Valve clocking (determining the radial orientation of the valve) should be performed to align the anterior cuff of Tendyne with A2 scallop, along the anterior atrial wall and behind the aortic valve. D. Transesophageal echocardiography, orthogonal biplanar imaging obtained from inter commissural view (left panel) showing the correct valve seating with no residual motion of the prosthesis and no LVOT obstruction (right panel: long axis view). E. 3D transesophageal echocardiography en face (surgeon’s view) — the final result. F. 3D transesophageal echocardiography ventricular view showing the final result

Abbreviations: Ao, aorta; LA, left atrium; LAA, left atrial appendage; LV, left ventricle

A

B

C

D

E

F

2. Haponiuk I, Chojnicki M, Paczkowski K, et al. Pediatric Melody mitral valve replacement in acute endocarditis: 2 consecutive cases operatedon with an alternative hybrid technique. Kardiol Pol. 2020; 78(1): 75–77, doi:

10.33963/KP.15132, indexed in Pubmed: 31922500.

Cytaty

Powiązane dokumenty

figure 1 A – an immobilized mitral prosthesis disc (arrow); 3‑dimensional transesophageal echocardiography (3D TEE), left atrial view; B – pathological masses on the

Figure 2 Monitoring of the process of pulling on the cardiac walls during lead dissection: A ‒ fluoroscopy showing  the extraction of a high ‑voltage lead, adhesion of

As to date there are no studies com- paring mitral paravalvular leak closure with or without fusion technology, we hypothesize that periprocedural fusion of cardiac fluoroscopy

Comparison of real-time two-dimensional transesophageal echocardiography (RT2D TEE) versus real-time three-dimensional transesophageal echocardiography (RT3D TEE) results of

Left atrial appendage peak antegrade flow velocity measured during the procedure before (A) and minutes after (B) transcatheter aortic valve implantation with help of

With its unique en face view, real time three-dimensional transesophageal echocardiography has been reported to be more precise than conventional two-dimensional studies in

Conclusions: Pre-operative forward stroke volume and right ventricle size are predictors of the perioperative hemodynamic status in patients with mitral regurgitation undergoing

Apical 3-chamber view (A3C) showing the pro- sthesis echogram 10–15 mm (arrow) above the level of the native mitral annulus (arrow).... 315 Barbara Brzezińska, Mitral valve