Advances in Interventional Cardiology 2019; 15, 1 (55)

Short communication

Corresponding author:

Bartosz Rymuza MD, 1st Department of Cardiology, Medical University of Warsaw, 1 a Banacha St, 02-097 Warsaw, Poland, phone: +48 505 402 390, e-mail: bartosz.rymuza@gmail.com

Received: 10.10.2018, accepted: 25.12.2018.

Transcatheter mitral valve-in-valve implantation using a transseptal approach

Zenon Huczek, Bartosz Rymuza, Piotr Scisło, Janusz Kochman, Krzysztof J. Filipiak, Grzegorz Opolski

1st Department of Cardiology, Medical University of Warsaw, Warsaw, Poland

Adv Interv Cardiol 2019; 15, 1 (55): 107–109 DOI: https://doi.org/10.5114/aic.2019.83775

Transcatheter mitral valve-in-valve intervention (TMVI) is an alternative mode of treatment to re-do surgery for bioprosthetic valve failure. Although transapical access represents the shortest route to deliver the new biopros- thesis in the mitral position, currently the transseptal route is becoming more popular [1, 2]. We present the first case in Poland of TMVI using transseptal access.

A  69-year-old female patient who underwent surgi- cal mitral valve replacement with an Epic 31 mm (Abbot) valve, after 2 ischemic strokes with pulmonary hyperten- sion and chronic kidney disease stage 4 (EuroSCORE II 9.8%), developed dyspnea 3 years following surgery (NYHA class III). Echocardiographic examination revealed signs of severe stenosis and mild insufficiency of the Epic valve. After discussion at the heart team meeting, due to high risk of a  re-do operation the patient was referred for TMVI.

Based on the internal lumen diameter of the Epic valve the suggested valve size should be 29  mm (Fig- ure 1 A), but cardiac computed tomography (CCT) revealed extensive hypodense pannus formation with mean inner lumen diameter of 21 mm (Figure 1 B). Because of this appearance it was agreed to perform balloon sizing of the degenerated bioprosthesis with a 22 mm balloon cathe- ter. The patient was screened for possible left ventricular outflow tract (LVOT) obstruction by means of neo-LVOT calculation and aorto-mitral angulation, showing no or little risk of obstruction (Figures 1 C–E) [3, 4].

The procedure was performed via the transvenous route in general anesthesia under transesophageal echo- cardiography (TEE) guidance. After puncture of the inter- atrial septum in postero-inferior location and crossing through the degenerated valve into the left ventricle, dil- atation of the intra septal channel was performed with a  12 × 40  mm peripheral balloon catheter. Predilation with a 22 mm balloon catheter was performed and upon

inflation a  clear waist was visible (Figure 2 A); therefore a 26 mm Sapien 3 (Edwards Lifesciences) valve was cho- sen. Despite the previous dilatation of the intra-septal channel the crossing with the delivery system showed some difficulty, but after changing to a Lunderquist Extra Stiff guidewire and some mild dilatation of the distal part of the Edwards balloon it was possible to obtain correct positioning (Figure 2 B). During rapid pacing the valve was implanted in a 20%/80% (atrium/ventricle) depth ratio and afterwards postdilated distally with an extra 2 ml of vol- ume to obtain a wider, cone-shaped, ventricular end of the valve. In post-procedural angiography there were no signs of paravalvular regurgitation (Figure 2 C), and TEE showed good expansion of the implanted valve (Figure 2 D).

In carefully selected patients TMVI is a forward-look- ing method enabling less invasive treatment for severe mitral prosthesis failure. With the use of proper implan- tation technique [5, 6] the procedure is safe and feasible via the transfemoral venous route. The most crucial part of planning the procedure, besides screening for possi- ble LVOT obstruction, is valve sizing. Given the possibility of late valve migration, undersizing should be avoided in most cases. In those situations the true ID should be chosen as the proper diameter to size the valve. In cas- es with extensive hypodense pannus formation or cal- cifications within the bioprosthetic valve an alternative may be used. Although controversial, balloon sizing may prove useful to determine the strength and flexibility of additional tissue found within the stent of the degen- erated bioprosthesis, therefore providing new informa- tion on the appropriate transcatheter valve size for mitral valve-in-valve procedures.

Acknowledgments

The authors want to thank Prof. Markus Kassel for his technical expertise and assistance during the procedure.

(2)

Zenon Huczek et al. TMVI using transseptal approach

108 Advances in Interventional Cardiology 2019; 15, 1 (55)

Figure 1. Pre-procedural cardiac computed to- mography analysis. A  – Internal dimensions (ID) of Epic 31 mm valve; based on the Valve in Valve app – true ID = 26.5  mm. B – CT-ID, dimensions of the true lumen. C – Aorto-mitral angulation (AMA) suggesting low risk of LVOT obstruction (wider than 120°). D, E – Neo-LVOT calculation with virtual valve implantation showing an area above 2.0 cm2, which could increase the risk of LVOT obstruction

A B

C D

E

(3)

Zenon Huczek et al. TMVI using transseptal approach

109

Advances in Interventional Cardiology 2019; 15, 1 (55)

Conflict of interest

The authors declare no conflict of interest.

References

1. Kamioka N, Babaliaros V, Morse M, et al. Comparison of clinical and echocardiographic outcomes after surgical redo mitral valve replacement and transcatheter mitral valve-in-valve therapy.

J Am Coll Cardiol Interv 2018; 11: 1131-8.

2. Eleid M, Whisenant B, Cabalka A, et al. Early outcomes of percu- taneous transvenous transseptal transcatheter valve implanta- tion in failed bioprosthetic mitral valves, ring annuloplasty, and severe mitral annular calcification. J Am Coll Cardiol Interv 2017;

10: 1932-42.

3. Bapat V, Pirone F, Kapetanakis S, et al. Factors influencing left ventricular outflow tract obstruction following a  mitral valve- in-valve or valve-in-ring procedure, part 1. Catheter Cardiovasc Interv 2015; 86: 747-60.

Figure 2. Transcatheter mitral valve-in-valve implantation. A – Predilatation of a 31 mm Epic bioprosthesis with a 22 mm balloon catheter. The waist is clearly visible (white arrows). B – Edwards SAPIEN 3 26 mm delivery.

In order to facilitate the delivery, mild balloon inflation (white arrow) and changing to a Lunderquis Extra Stiff guidewire (asterisk) was performed. C – Final angiography showing no residual paravalvular leak (PVL). Aorta and left ventricle marked with white dotted line; red dotted line – Epic 31 mm valve stent. D – Postprocedural photorealistic TEE (Philips Epic CVx) showing excellent prosthesis position and no PVL

A B

C D

4. Murdoch DJ, Webb JG. LAMPOON’s European vacation. EuroInt- ervention 2018; 14: 736-8.

5. Shivaraju A, Michel J, Frangieh A, et al. Transcatheter aortic and mitral valve-in-valve implantation using the Edwards Sapien 3 Heart Valve. J Am Heart Assoc 2018; 7: e007767.

6. Dvir D, Webb J. Mitral valve-in-valve and valve-in-ring: technical aspects and procedural outcomes. EuroIntervention 2016; 12:

Y93-6.

Cytaty

Powiązane dokumenty

figure 1 A – multislice contrast computed tomography of implanted bioprosthesis and the ascending aorta, the short axis view; B – multislice contrast computed tomography of

Correlations between effective regurgitant orifice area, mitral regurgitation volume, and transcatheter aortic valve implantation No correlation between MR ‑EROA reduction

ence of >48° angle between the aortic annulus Transcatheter aortic valve implantation (TAVI)4. is a well ‑established modern treatment of severe symptomatic

tion in mean (SD) transvalvular gradients after the placement of transcatheter implanted valve in surgical implanted valve of 19.0 (8.8) mm Hg (P <0.001) and a further mean

short ‑axis view; C – echocardiography imaging of implanted valvular prostheses after severe paravalvular regurgitation: long ‑axis view; D – removed infected valvular

Prosthetic valve endocarditis and acute heart failure in a patient after transcatheter aortic valve implantation procedure.. Tomasz Skowerski, Patryk Grzywocz, Mariusz Bałys,

Transthoracic (TTE) and transesopha- geal (TEE) echocardiography revealed a degenerated bi- oprosthesis in the mitral position with severe eccentric regurgitation (Figure 1 A);

As a result it was noted that TAVI with a CoreValve (Medtronic, Inc, Minneapolis, MN, USA) was technically possible in high-risk patients with mechanical mitral valves or