Address for correspondence: Jarosław Meyer-Szary, MD, PhD, Assistant teacher, Department of Pediatric Cardiology and Congenital Heart Diseases, Medical University of Gdansk, ul. M. Skłodowskiej-Curie 3a, 80–210 Gdańsk, Poland, tel: +48 58 349 2882, fax: +48 58 349 2890, e-mail: jmeyerszary@gumed.edu.pl

Received: 2.04.2020 Accepted: 5.05.2020

Follow-up on results of three-dimensional printed model aided unusual intervention on aneurysm of aortic arch lesser curvature

Robert Sabiniewicz

1

, Jarosław Meyer-Szary

1

, Lidia Woźniak-Mielczarek

1

, Dominika Sabiniewicz

2

1Department of Pediatric Cardiology and Congenital Heart Diseases, Medical University of Gdansk, Poland

22nd Department of Radiology, Medical University of Gdansk, Poland

A recent article “Feasibility of in-house rapid prototyping of cardiovascular three-dimensional models for planning and training non-standard in- terventional procedures” [1] presented the useful- ness of three-dimensional (3D) printed models in planning unusual procedures in atypical structural heart defects. In particular, the model was used to plan the procedure of closing an aneurysm on the lesser curvature of the aortic arch in a patient after previous surgery for aortic coarctation (Fig. 1A).

Thanks to the prepared model, the type and size of the closing implant were selected, optimal vascular access path was chosen, and technique of the pro- cedure was practiced. This allowed for shortening the time of procedure, perform it without complica- tions, and with a good direct result. This proves the usefulness of personalized printouts of 3D models described in the literature in planning unusual or complicated interventions [1–3].

Herein, is presented follow-up details and treatment results of a previously presented case.

Post 6 months the patient did not present any symptoms or complain of discomfort. A follow-up computed tomography scan showed a good long- -term outcome. The aneurysm orifice was closed with an ADO implant remaining in the correct

position (Fig. 1B). There was no narrowing or flow disorder in the aortic arch and no inflow to the aneurysm that was completely closed. The procedure of closing the aneurysm prevented its further enlargement or increasing pressure on surrounding structures most importantly the left pulmonary artery. Presented 3D reconstructions compare the baseline situation and the remote outcome of the procedure.

Conflict of interest: None declared

References

1. Meyer-Szary J, Woźniak-Mielczarek L, Sabiniewicz D, et al.

Feasibility of in-house rapid prototyping of cardiovascular three- -dimensional models for planning and training non-standard in- terventional procedures. Cardiol J. 2019; 26(6): 790–792, doi:

10.5603/CJ.2019.0115, indexed in Pubmed: 31970736.

2. Luo H, Meyer-Szary J, Wang Z, et al. Three-dimensional printing in cardiology: Current applications and future challenges. Cardiol J.

2017; 24(4): 436–444, doi: 10.5603/CJ.a2017.0056, indexed in Pubmed: 28541602.

3. Sabiniewicz R, Meyer-Szary J, Potaż P, et al. Melody valve implantation pre-procedural planning using custom-made 3D printed model of the region of interest. Adv Intercv Cardiol.

2018; 14(2): 210–211, doi: 10.5114/aic.2018.76419, indexed in Pubmed: 30008780.

447 www.cardiologyjournal.org

CLINICAL CARDIOLOGY

Cardiology Journal 2020, Vol. 27, No. 4, 447–448

DOI: 10.5603/CJ.2020.0122 Copyright © 2020 Via Medica

ISSN 1897–5593

LETTER TO THE EDITOR

(2)

Figure 1. Computed tomography volume rendering reconstruction showing the anatomy before the procedure (A) and after (B). The arrows show the aneurysm on the lesser curvature of the aortic arch and the ADO implanted to close it. Detrailed description in the text.

A B

448 www.cardiologyjournal.org

Cardiology Journal 2020, Vol. 27, No. 4

Cytaty

Powiązane dokumenty

Therefore, the main objective of this study was to examine the changes in material stiffness, strength, and weight of 3D-printed PLA samples as a consequence of both long and

W. Ceran (UŁ) – Przykłady z ży cia wzięte w kazaniach Jana Chryzostoma; ks. prof.  dr hab. S. Longosz (KUL) – Duszpasterstwo rodzin u Jana

Abstract: The basic three-dimensional dynamical problems for a hemitropic (non-centrally symmetric) micropolar elastic medium are con- sidered... 2 Statement of the

Laddermill is a flexible multi-body structure consisting of the kites and the cable; thus its mathematical model includes models of both.. Kites are assumed rigid so that equations of

Jankowska podkreśla, iż analizując treści prawa do autorstwa utworu w Stanach, można zauważyć, że jest ono rozumiane szeroko jako prawo do żądania wskazania swojej

By a two dimensional stability analysis for blade surface cavity in cascades [1], it was found that the steady cavity length is the dominating factor of cavitation instabilities

The design methodology to realise an integrated multi-functional magnetic structure, especially for the high conversion ratio ac-dc requirements of the PCB-assembled power converter,

According to Scott (1985), acts of daily resistance have political potential and for that reason, it is crucial to capture the continuum created by the political and