Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1340 z dnia 28.07.2020 r.
Cykl akredytacji od 28.07.2020 r. do 29.07.2024 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 1340 of 28.07.2020
Accreditation cycle from 28.07.2020 to 29.07.2024
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Issue No 12, 12 of 15.07.2021 1/22
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No AB 1340
wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 12 z/of 12 z/of 15.07.2021
Wersja strony/Page version: A Nazwa i adres / Name and address
Institute for Research and Certification OBAC Ltd.
Łabędzka street 21 44-121 Gliwice
LABOREx Laboratory
Aronii street 4 44-102 Gliwice, Poland
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- A/13 - Badania akustyczne i hałasu – w tym spowodowanego przez drgania maszyn / Acoustic and vibration tests of Machinery and devices,
- E/6; E/13 - Badania elektryczne wyrobów elektrycznych, wyposażenia maszyn / Electric tests of electric products and machinery equipment,
- G/9 - Badania dotyczące inżynierii środowiska – hałas w środowisku pracy, hałas pochodzący od instalacji i urządzeń przemysłowych / Tests concerning environmental engineering – noise in workplace, noise generated by industrial instalation and devices
- H/21 - Badania ogniowe wyrobów z tworzyw sztucznych i gumy / Fire tests of plastic and rubber products - J/6; J/8; J/13; J/21 - Badania mechaniczne wyrobów i wyposażenia elektrycznego, wyrobów konstrukcyjnych i wyposażenia
maszyn, wyrobów z tworzyw sztucznych i gumy, pojazdów / Mechanical tests of products and electric equipment , construction products and machine equipment, plastic and rubber products, vehicle - N/6 - Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego, wyrobów konstrukcyjnych i
wyposażenia maszyn, wyrobów z tworzyw sztucznych i gumy, sprzętu sportowego i rekreacyjnego / Tests of physical properties and electric equipment, construction products, machine devices, plastic and rubber products, sport equipment.
AB 1340
Edition no 12,15.07.2021 2/22 Laboratory of Electric Tests
Tested objects/Group of objects
Tested features and test/
measurement methods
Standards and/or documented testing procedures Electrical equipment for use in
potentially explosive atmospheres
Geometric linear dimensions
Method: direct PN-EN IEC 60079-0:2018-09
Resistance to impact
Range: Impact energy of up to 20J
PN-EN IEC 60079-0:2018-09 Resistance to drop-test impact PN-EN IEC 60079-0:2018-09 Thermal tests, temperatures and
temperature rise of up to +450°C PN-EN IEC 60079-0:2018-09 Thermal endurance to heat
Range: up to 180°C
PN-EN IEC 60079-0:2018-09 Thermal endurance to cold
Range: down to -75°C
PN-EN IEC 60079-0:2018-09
Cable glands PN-EN IEC 60079-0:2018-09
PN-G-50003:2003 Electrical equipment for
potentially
explosive atmospheres – Equipment protection by flameproof enclosures “d” – Cemented joints and sealed with cement
Geometric linear dimensions
Method: direct PN-EN 60079-1:2014-12
Explosion pressure, reference pressure Range: up to 3 MPa
Method: Measurement of maximum explosion pressure
PN-EN 60079-1:2014-12
Ability of the enclosure to withstand pressure
Range: up to 3 MPa
Method: static pressurization
PN-EN 60079-1:2014-12
Protection against non-transmission of explosion
PN-EN 60079-1:2014-12 Flameproof cable glands
Range: up to 3 MPa, Torque of up to 150
Nm
PN-EN 60079-1:2014-12
Electrical equipment for potentially
explosive atmospheres – Equipment protection by pressurized enclosure “p”
Geometric linear dimensions Method: direct
PN-EN 60079-2:2015-02 Ability of the enclosure to withstand
pressure
Range: up to 3 MPa
Method: static pressurization
PN-EN 60079-2:2015-02
Enclosure tightness Range: up to 3 MPa
Method: static pressurization
PN-EN 60079-2:2015-02
Containment system infallibility Range: up to 3 MPa
Method: static pressurization
PN-EN 60079-2:2015-02
Electrical equipment for potentially
explosive atmospheres – Equipment protection by powder filling “q”
Geometric linear dimensions Method: direct
PN-EN 60079-5:2015-08 Ability of the enclosure to withstand
pressure
PN-EN 60079-5:2015-08 IP degree of protection
Range of IP: 1X, 2X, 5X, 6X, X4, X5, X6, X7, X8
PN-EN 60079-5:2015-08
Thermal tests, temperatures and
temperature rise of up to 450°C PN-EN 60079-5:2015-08
Wersja strony: A
Edition no 12,15.07.2021 3/22 Tested objects/Group of objects Tested features and test/
measurement methods Standards and/or documented testing procedures Explosive atmospheres
Equipment protection by liquid immersion "o"
Type tests:
- Overpressure testing of sealed housings
- Reduced pressure testing of sealed housings
- Overpressure testing of unsealed casings
- Maximum temperature
- Switching studies Routine tests:
- Sealed housings - Unsealed housings
PN-EN 60079-6:2016-02
Electrical equipment for potentially
explosive atmospheres – Equipment protection by increased
safety “e”
Geometric linear dimensions Method: direct
PN-EN 60079-7:2016-02 +A1:2018-03
Insulation dielectric strength
Range: alternating voltage of up to 20 kV
PN-EN 60079-7:2016-02 +A1:2018-03
Electrical equipment for potentially
explosive atmospheres –
Equipment protection by intrinsic safety “i”
Geometric linear dimensions
Method: direct PN-EN 60079-11:2012
Creepage distances and clearances Direct measurement
PN-EN 60079-11:2012 Insulation dielectric strength
Range: alternating voltage of up to 20 kV
PN-EN 60079-11:2012
Capacity of cells and batteries Resistance of cells and batteries to shortcircuit
PN-EN 60079-11:2012
Mechanical resistance of casting compound
PN-EN 60079-11:2012 Transformer insulation resistance PN-EN 60079-11: 2012 Spark-initiated ignition attempt PN-EN 60079-11 :2012 Electrical equipment for
potentially
explosive atmospheres – Equipment protection by type of protection “n”
Geometric linear dimensions Method: direct
PN-EN IEC 60079-15:2019-06 Thermal endurance to heat
Range: up to 180°C PN-EN IEC 60079-15:2019-06 Resistance to drop-test impact PN-EN IEC 60079-15:2019-06 Insulation dielectric strength
Range: alternating voltage of up to 20 kV
PN-EN IEC 60079-15:2019-06
Electrical equipment for potentially
explosive atmospheres – Equipment protection by encapsulation “m”
Thermal tests, temperatures and
temperature rise of up to 450°C PN-EN 60079-18:2015-06 +A1:2018-02
Thermal endurance to heat
Range: up to 180°C PN-EN 60079-18:2015-06 +A1:2018-02
Thermal endurance to cold Range: down to -75°C
PN-EN 60079-18:2015-06 +A1:2018-02
Insulation dielectric strength
Range: alternating voltage up to 20 kV
PN-EN 60079-18:2015-06 +A1:2018-02
Ability of the enclosure to withstand pressure
Range: up to 3 MPa
Method: static pressurization
PN-EN 60079-18:2015-06 +A1:2018-02
Compound test, water absorption test PN-EN 60079-18:2015-06 +A1:2018-02
Edition no 12,15.07.2021 4/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Electrical equipment for
potentially
explosive atmospheres – Intrinsically safe electrical systems
Geometric linear dimensions Method: direct
PN-EN 60079-25:2011 Separation distances,
Direct measurement PN-EN 60079-25:2011
Insulation dielectric strength
Range: alternating voltage of up to 20 kV
PN-EN 60079-25:2011
Capacity of cells and batteries Resistance of cells and batteries to shortcircuit
PN-EN 60079-25:2011
Mechanical resistance of casting compound
PN-EN 60079-25:2011 Transformer insulation resistance PN-EN 60079-25:2011 Electrical equipment for
potentially
explosive atmospheres – Equipment with equipment protection level (EPL) Ga
Resistance to impact
Range: impact energy of up to 20 J
PN-EN 60079-26:2015-04 Thermal tests, temperatures and
temperature rise of up to 450°C
PN-EN 60079-26:2015-04
Electrical equipment for potentially
explosive atmospheres – Equipment dust ignition protection
by enclosure “t”
IP degree of protection
Range of IP: 1X, 2X, 5X, 6X, X4, X5, X6,X7, X8
PN-EN 60079-31:2014-10 IEC 60079-31:2013 Resistance to impact
Range: impact energy of up to 20 J
PN-EN 60079-31:2014-10 IEC 60079-31:2013 Ability of the enclosure to withstand
pressure
Range: up to 3 MPa
Method: static pressurization
PN-EN 60079-31:2014-10 IEC 60079-31:2013
Thermal tests, temperatures and temperature rise
Range: up to +450°C
PN-EN 60079-31:2014-10 IEC 60079-31:2013 Solid planar materials used to
avoid electrostatic charge accumulation
Surface resistance of non-metallic materials
Range: up to R = 1 x 1012 Ω
PN-EN 60079-32-2:2015-08
Resistance between non-metallic materials points
Range: up to R = 1 x 1012 Ω
PN-EN 60079-32-2:2015-08
Volume resistance of non-metallic materials
Range: up to R = 1 x 1012 Ω
PN-EN 60079-32-2:2015-08
Machines and equipment.
Degrees of protection provided by
enclosures (IP code)
IP degree of protection
Range of IP 1X, 2X, 3X, 4X, 5X, 6X, X4, X5, X6, X7, X8, X9
PN-EN 60529:2003+A2:2014-07 PN-G-50003:2003
PN-EN IEC 60034-5:2021-01 Machines and equipment.
Degrees of protection provided by enclosures (IK code)
IP degree of protection
Range of IK 01, 02, 03, 04, 05, 06, 07, 08, 09, 10
Method: Test Ehc Vertical hammer
PN-EN 62262:2003
PN-EN 60068-2-75:2015-01
Non-electrical equipment for use in potentially explosive
atmospheres
Geometric linear dimensions
Method: direct PN-EN ISO 80079-36:2016-07
wg Załącznika ZC Resistance to impact
Range: impact energy of up to 20 J Resistance to drop-test impact Maximum surface temperature Range: up to +450°C
Non-electrical type of protection constructional safety ''c'', control of ignition sources ''b'', liquid immersion ''k''
Pressure resistance of the housing Range: up to 3 MPa
Method: static pressure load
PN-EN ISO 80079-37:2016-07 wg Załącznika ZB
Wersja strony: A
Edition no 12,15.07.2021 5/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Solid planar materials used to
avoid electrostatic charge accumulation
Surface resistance of non-metallic materials
Range: up to R = 1 x 1012 Ω
PN-EN 61340-2-3:2016-11
Resistance between non-metallic materials points
Range: up to R = 1 x 1012 Ω
PN-EN 61340-2-3:2016-11
Volume resistance of non-metallic materials
Range: up to R = 1 x 1012 Ω
PN-EN 61340-2-3:2016-11 Surface resistance of non-metallic
housing parts
PN-EN IEC 60079-0:2018-09 Surface resistance PN-EN ISO 80079-36:2016-07 Non-electrical equipment for
explosive atmospheres
Breakdown voltage PN-EN ISO 80079-36:2016-07
Electrical machines and mining equipment
Creepage distances and clearances Direct measurement
PN-G-50003:2003 Insulation resistance
Range: up to 1TΩ (at U = 5 kV)
PN-G-50003:2003 Insulation electrical strength
Range: alternating voltage of up to 20 kV
PN-G-50003:2003
The equipment and insulation thermal endurance to humid constant heat Range: up to 95°C and up to 98% RH Method: Cab test
PN-G-50003:2003
Thermal endurance to cold Range: down to -75°C
PN-G-50003:2003 Thermal endurance to dry heat
Range: up to 180°C PN-G-50003:2003
Heating, temperatures and temperature
Rise, Range: up to +450°C
PN-G-50003:2003
Cable and conductor glands PN-G-50003:2003
PN-EN IEC 60079-0:2018-09 Machines and equipment
(including electrical) Thermal resistance to cold Range: down to -75°C Method: Test A
PN-EN 60068-2-1:2009
Resistance to dry heat Range: up to + 160 ° C Method: Test Bb; Trial of Bd;
Attempt at Be
PN-EN 60068-2-2:2009
Test Db: Damp cyclic heat (12h + 12h
cycle) PN-EN 60068-2-30:2008
Thermal resistance to humid constant Heat, Range: up to 95°C and to 98%
RH
Method: Cab test
PN-EN 60068-2-78:2013-11
Wersja strony: A
Edition no 12,15.07.2021 6/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Electrical appliances for
household and similar
- Checking marking
- Check the power and current - Check heating
- Check the leakage current and electric strength at operating temperature - Test for moisture
- Check the leakage current and electric strength
- Check the overload protection of the transformer and circuits fed from the transformer
- Check the operation under abnormal conditions
- Check the internal wiring
- Checking the grounding connection - Check the screws and connections - Check the insulation distances of air and
surface and the thickness of solid insulation
- Check the start-up of equipment with motorized
- Check the wear resistance - Check the stability and mechanical hazard
- Verification of components,
Checking the connection to the power supply and external hoses
- Check the external wiring terminal
PN-EN 60335-1:2012 +A11:2014-10+A13:2017-11 +A1:2019-10+A2:2019-11 +A14:2020-05
Vacuum cleaners and water- suction cleaning appliances
PN-EN 60335-2-2:2010 +A1:2013-05+A11:2013-05
Electric irons PN-EN 60335-2-3:2016-03
Stationary cooking ranges, hobs,
ovens and similar appliances PN-EN 60335-2-6:2015-05
+A1:2020-07+A11:2020-09 Shavers, hair clippers and
similar appliances
PN-EN 60335-2-8:2015-12 +A1:2016-04
Grills, toasters and similar portable cooking appliances
PN-EN 60335-2-9:2007+A12:2008 +A13:2011
Floor treatment machines and
wet scrubbing machines PN-EN 60335-2-10:2004+A1:2008
Warming plates and similar
appliances PN-EN 60335-2-
12:2004+A1:2008+A2:2019- 11+A11:2019-11
Deep fat fryers, frying pans and
similar appliances PN-EN 60335-2-
13:2010+A11:2012+A1:2019-11
Kitchen machines PN-EN 60335-2-14:2009+A1:2009
+A11:2012+A12:2016-03
Appliances for heating liquids PN-EN 60335-2-15:2016-04/
+A11:2018-10
Food waste disposers PN-EN 60335-2-16:2004+A1:2008
+A2:2012+A11:2018-09 Blankets, pads, clothing and
similar flexible heating appliances
PN-EN 60335-2-17:2013-06 +A11:2019-11+A1:2020-09
Storage water heaters PN-EN 60335-2-21:2006+A2:2009
Appliances for skin or hair care PN-EN 60335-2-23:2006+A1:2008
+A11:2010+A2:2015-03 Refrigerating appliances, ice-
cream appliances and ice makers PN-EN 60335-2-24:2010 +A1:2019-
01+A2:2019-02+A11:2020-11
Microwave ovens, including combination microwave ovens
PN-EN 60335-2-25:2012 +A1:2015-11+A2:2016-04
Sewing machines PN-EN 60335-2-28:2004+A1:2008
+A11:2018-10
Battery chargers PN-EN 60335-2-29:2005+A2:2010
+A11:2018-11
Room heaters PN-EN 60335-2-30:2010
+A11:2012+A1:2020-09 +A12:2021- 02
Range hoods and other cooking
fume extractors PN-EN 60335-2-31:2015-02
Edition no 12,15.07.2021 7/22 Particular requirements for
massage appliances
- Checking marking
- Check the power and current - Check heating
- Check the leakage current and electric
strength at operating temperature - Test for moisture
- Check the leakage current and electric
strength
- Check the overload protection of the transformer and circuits fed from the transformer
- Check the operation under abnormal conditions
- Check the internal wiring
- Checking the grounding connection - Check the screws and connections - Check the insulation distances of air and
surface and the thickness of solid insulation
- Check the start-up of equipment with motorized
- Check the wear resistance - Check the stability and mechanical hazard
- Verification of components,
Checking the connection to the power supply and external hoses
- Check the external wiring terminal
PN-EN 60335-2-32:2009 +A2:2015-03
Particular requirements for
instantaneous water heaters PN-EN 60335-2-35:2016-
03+A1:2020-05 Particular requirements for
commercial electric doughnut fryers and deep fat fryers
PN-EN 60335-2-37:2009+
A11:2012+A12:2016-05
Particular requirements for electrical heat pumps, air- conditioners and dehumidifiers
PN-EN 60335-2-40:2004+A11:2005 +A12:2005+A1:2006+A2:2009 +A13:2012
Particular clothes dryers and towel rails
PN-EN 60335-2-43:2005+A1:2006 +A2:2009
Portable heating tools and similar appliances
PN-EN 60335-2-45:2007+A1:2008 +A2:2012
Commercial electric appliances for
keeping food and crockery warm PN-EN 60335-2-
49:2010+A11:2012+A2:2020-05
Oral hygiene appliances PN-EN 60335-2-52:2004+A1:2008
+A11:2010+A12:2020-04 Particular requirements for sauna
heating appliances and infrared cabins
PN-EN 60335-2-53:2012
Surface-cleaning appliances for household use employing liquids or steam
PN-EN 60335-2-54:2009 +A11:2013-05+A1:2015-11
Projectors and similar appliances PN-EN 60335-2-56:2003+A1:2008
+A2:2014-12 Particular requirements for insect
killers PN-EN 60335-2-59:2007+A2:2010
+A11:2018-12
Thermal storage room heaters PN-EN 60335-2-61:2008+A2:2009
Water-bed heaters PN-EN 60335-2-66:2003+A1:2008
+A2:2012+A11:2020-01
Portable immersion heaters PN-EN 60335-2-74:2008+A2:2010
+A11:2018-11 Commercial dispensing appliances
and vending machines
PN-EN 60335-2-75:2005+A1:2005 +A11:2006+A2:2009+A12:2010
Outdoor barbecues PN-EN 60335-2-78:2004
+A1:2008+A11:2020-07
Fans PN-EN 60335-2-80:2007+A2:2009
Foot warmers and heating mats PN-EN 60335-2-81:2003+A1:2007
+A2:2012
Edition no 12,15.07.2021 8/22 Amusement machines and
personal service machines
PN-EN 60335-2-82:2004 +A1:2008+A2:2020-07
Humidifiers intended for use with heating, ventilation, or air- conditioning systems
PN-EN 60335-2-88:2003
Commercial refrigerating
appliances and ice-makers with an incorporated or remote refrigerant unit or motor-compressor
PN-EN 60335-2-89:2012 +A1:2016- 04+A2:2018-04
Flexible sheet heating elements for
room heating PN-EN 60335-2-96:2005+A2:2009
Drives for shutters, awnings,
blinds and similar equipment PN-EN 60335-2-97:2007+A11:2008
+A2:2010+A12:2015-02
Humidifiers PN-EN 60335-2-
98:2009+A2:2009+A11:2020-01 Gas, oil and solid-fuel burning
appliances having electrical connections
PN-EN-60335-2-102:2016-03
Edition no 12,15.07.2021 9/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Heating boilers for solid fuels,
manually and automatically stoked, nominal heat output of up to 500 kW
- Determination of the consumption of auxiliary electricity;
- Determination of the temperature of the outer surface;
- Testing the operation of the temperature regulator and the safety temperature limiter of the heating boiler
PN-EN 303-5:2012
Luminaires - Strength marking
- Mechanical and electrical construction with the exception of: requirements for vibration and UV radiation
- The correctness of external and internal
wiring
- Adapting to the ground
- Protection against electric shock - Resistance to dust, solids and water - Insulation resistance and electric strength, current, protective conductor current
- Clearances surface and air
- Hardness test and attempt Thermal - Resistance to heat, fire and to stray currents
- The correctness of the construction screw terminals
- The correctness of the construction of terminals screwless electrical
connectors
PN-EN 60598-1:2015-04 +A1:2018- 04
PN-IEC 598-2-1:1994+Ap1:2000 EN 60598-2-1:1989
PN-EN 60598-2-4:2018-06 PN-EN 60598-2-5:2016-02 PN-EN 60598-2-24:2014-02 PN-EN 60598-2-2:2012
Low-voltage switchgear and
controlgear assemblies - Verification of marking - Test for raising
- Check the degree of protection (IP code)
- Check the insulation distances of air and surface
- Check the effectiveness of the protective circuit
- Verification of dielectric properties - Check the temperature rise - Checking the insulation resistance - Electrical strength test of insulation - Verification of protection against residual voltages
PN-EN 61439-1:2011 PN-EN 61439-2:2011 PN-EN 61439-3:2012 PN-EN 61439-4:2013-06 PN-EN 61439-5:2015-02 PN-EN 62208:2011 Safety of machinery - Electrical
equipment of machines PN-EN 60204-1:2018-12
Edition no 12,15.07.2021 10/22 Hand - held motor - operated
electric tools
- Marking check
- Verification of protection against access to live parts
- Boot check
- Check power consumption and current
- Heating check
- Leakage current check - Moisture resistance check - Checking the electrical strength - Checking the protection against overload of the transformer and the circuits supplied from the transformer - Checking long-term work
- Checking the operation of the device in abnormal conditions
- Checking the protection against mechanical damage
- Checking the structure - Check the internal wiring - Checking the component parts - Checking the connection to the power supply and flexible connection cables
- Checking the external wiring - Checking the earthing connection - Checking screws and connections - Checking surface and air insulation gaps and the thickness of solid insulation
- Durability check - Rust resistance test - Checking resistance to high temperature and fire
PN-EN 60745-1:2009+A11:2011 PN-EN 62841-1:2015-11
Drills and impact drills PN-EN 60745-2-1:2010
PN-EN 62841-2-1:2018- 03+A11:2020-03 Screwdrivers and impact
wrenches
PN-EN 60745-2-2:2010 PN-EN 62841-2-2:2015-03
Grinders, polishers and disk-type sanders
PN-EN 60745-2-3:2011 +A2:2014-01+A11:2015-01+
A12:2015-08+A13:2016-03 Sanders and polishers other than
disk type PN-EN 60745-2-4:2010+A11:2012
PN-EN 62841-2-4:2015-02
Circular saws PN-EN 60745-2-5:2011
PN-EN 62841-2-5:2015-02
Hammers PN-EN 60745-2-6:2010
Shears and nibblers PN-EN 60745-2-8:2009
PN-EN 62841-2-8:2017-01
Tappers PN-EN 60745-2-9:2009
PN-EN 62841-2-9:2015-07 Reciprocating saws (jig and
sabre saws)
PN-EN 60745-2-11:2010 PN-EN 62841-2-11:2016-08 +A1:2020-10
Concrete vibrators PN-EN 60745-2-12:2009
Chain saws PN-EN 60745-2-13:2009+A1:2011
PN-EN 62841-4-1:2020-08 z wyłączeniem pkt.19.107
Planers PN-EN 60745-2-14:2009+A2:2010
PN-EN 62841-2-14:2016-02
Hedge trimmers PN-EN 60745-2-15:2009+A1:2010
PN-EN 62841-4-2:2019-10
Tackers PN-EN 60745-2-16:2011
Routers and trimmers PN-EN 60745-2-17:2010
PN-EN 62841-2-17:2018-02
Strapping tools PN-EN 60745-2-18:2009
Jointers PN-EN 60745-2-19:2009+A1:2010
Band saws PN-EN 60745-2-20:2009
Drain cleaners PN-EN 60745-2-21:2009+A1:2011
PN-EN 62841-2-21:2019-08
Cut-off machines PN-EN 60745-2-22:2011
+A11:2013-10 Die grinders and small rotary
tools PN-EN 60745-2-23:2013-10
Edition no 12,15.07.2021 11/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Safety requirements for electrical
equipment for measurement, control, and laboratory use
- Marking and documentation - Protection against electric shock - Protection against mechanical hazards
- Device temperature limits and heat resistance
- Protection against the dangers of liquids
- Protection with locks
PN-EN 61010-1:2011+A1:2019-04
Medical electrical equipment Marking durability Legibility of the marking Voltage and stored charge measurement
Protective connection impedance Leakage Current:
- earth leakage current - touch leakage current - patient leakage current - patient auxiliary current - patient's total leakage current Insulating gaps Electrical strength of the insulation
Air and surface gaps
Heat resistance Range: up to 180 ° C Moisture initial stabilization Humidity range in climate mode up to 98%
Protection against mechanical hazards with the exception of point 9.5 and 9.6
Temperature during normal use Temperature of the applied parts Degree of protection against:
- overflow in a medical device, - dousing on a medical device, - ingress of water or solids into the medical device
Damage conditions excluding points 13.2.11
Construction, mechanical strength
PN-EN 60601-1:2011 +A1:2014-02+A12:2014-12
Safety of primary and secondary lithium cells and batteries during transport
- Checking the height simulation, - Thermal study, -
short circuit test, - Crushing test, - Forced discharge test - Fall test (packaging test)
UN TEST
Nr ST/SG/AC.10/11/Rev.7:2019 Test T1, T2, T5, T6, T8
IEC 62281:2019
Test T-1, T-2, T-5, T-6, T-8, P-1
Edition no 12,15.07.2021 12/22 Laboratory of Mechanical and Physical Research
Aronii 4 street, 44-102 Gliwice Poland Tested objects/Group of objects Tested features and test/
measurement methods Standards and/or documented testing procedures Plastics - Determination of
flexural properties Flexural strength
Load range: up to 1000 kN Bending test PN-EN ISO 178:2011+A1:2013-06 PN-EN ISO 178:2019-06
Compressive strength Load range: up to 1000 kN Bending test
PN-C-89071:1993
Methods of testing cement Determination of strength
Flexural strength Compressive strength Load range: up to 1000 kN Bending test
Compression test
PN-EN 196-1:2016-07
Rubber and plastic hoses and
hose assemblies Geometric linear dimensions Range: up to 150 mm Method: direct
PN-EN ISO 4671:2008+A1:2011
Resistance to test pressure Range: up to 2500 bar Method: static pressurization
PN-EN ISO 1402:2010
Resistance to bursting pressure Range: up to 2500 bar
Method: static pressurization
PN-EN ISO 1402:2010
Leakage
Range: up to 2500 bar Method: static pressurization
PN-EN ISO 1402:2010
Test with hydraulic pulsating pressure
without bending PN-EN ISO 6803:2017-04
Resistance to sheath abrasion
Range: 5 to 51 mm PN-EN ISO 6945:2002
PN-EN 853:2015-05 PN-EN 856:2015-05 PN-EN 856+AC:2019-04 PN-EN 854:2015-05 PN-EN 857:2015-05 PN-G-32010:2012 Method: flammability test PN-EN ISO 8030:2014-09 Surface resistance PN-EN ISO 8031:2021-01 Mining hydraulic drives and
control systems
Minimum destructive pressure Range: up to 2500 bar Method: static pressurization Geometric linear dimensions Range: up to 150 mm Method: direct
PN-G-32000:2011 DIN 20043:2003
Plastics and other non-metallic
materials Flammability – exposition time 10s PN-EN ISO 340:2013-07 p.5.7 except p.5.7.5 i p.5.7.6
Flammability PN-EN ISO 9773:2003+A1:2005
Flammability – method B PN-EN 60695-11-10:2014-02
Glow wire test PN-EN 60695-2-10:2013-02
PN-EN 60695-2-11:2015-02 Attempting to press in the ball PN-EN 60695-10-2:2014-10 Mining workings lining soldered
meshes Condition of surface
Visual method PN-G-15050:2018-01
Geometric dimensions Range: up to 2000 mm Mesh bending strength Load range: up to 1000 kN Rod material strength Load range: up to 1000 kN Soldered joint shear strength Load range: up to 1000 kN
Edition no 12,15.07.2021 13/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Roadway support base Dimensions and forms PN-G-15023:2019-03
Base resistance to piercing Funkcjonalność
Load range: up to 1000 kN Steel double-action props of
roadway supports
Dimensions PN-G-15024:2017-10
Transverse stability
Stability perpendicular to the prop axis Longitudinal stability
Load range: up to 100 kN Impact attenuating playground
surfaces Critical fall height
Range: height (0 to 3.7) m (HIC coefficient)
PN-EN 1177+AC:2019-04
Playground equipment and surfacing - Part 1: General safety requirements and test methods
Structural strength Method: strength test of structural elements
PN-EN 1176-1:2017-12 Accessible for adults Measurement of
geometric quantities Range: (0 - 3000) mm
PN-EN 1176-1:2017-12
Fall protection
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-1:2017-12
Finishing the device
Measurement of geometric quantities Range: (0 - 160) mm
PN-EN 1176-1:2017-12
Moving parts
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-1:2017-12
Protection against jamming Testing with samplers,
Measurement of geometric quantities Range:(0 - 3000) mm (0 - 220) ˚
PN-EN 1176-1:2017-12
Protection against injuries during movement and falling
Measurement of geometric quantities calculations
Range: (0 - 20,000) mm
PN-EN 1176-1:2017-12
Means of access
Measurement of geometric quantities Range: (0 - 3000) mm (0 - 220) ˚
PN-EN 1176-1:2017-12
Connections
Method: sensory method PN-EN 1176-1:2017-12 Wear parts
Method: sensory method PN-EN 1176-1:2017-12 Ropes
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-1:2017-12
Chains:
Measurement of geometric quantities Range: (0 - 160) mm
PN-EN 1176-1:2017-12
Hanging heavy beams Testing with samplers,
Measurement of geometric quantities force measurement
Range: (0 - 3000) mm (0 - 1000) N.
PN-EN 1176-1:2017-12
Marking
Method: sensory method
PN-EN 1176-1:2017-12
Edition no 12,15.07.2021 14/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Playground equipment and
surfacing - Part 2: Additional specific safety requirements and test methods for swings
Geometric dimensions
Measurement of geometric quantities calculations
Range: (0 - 20,000) mm
PN-EN 1176-2+AC:2020-01
Means of suspension
Measurement of geometric quantities Range: (0 - 3000) mm (0 - 220) ˚
PN-EN 1176-2+AC:2020-01
Fall height and impact surface Measurement of geometric quantities calculations
Range: (0 - 3000) mm (0 - 220) ˚
PN-EN 1176-2+AC:2020-01
Marking Method: sensory method Geometric dimensions
Measurement of geometric quantities Range: (0 - 3000) mm (0 - 220) ˚
PN-EN 1176-2+AC:2020-01
Playground equipment and surfacing - Part 3: Additional specific safety requirements and test methods for slides
Marking Method: sensory method Geometric dimensions
Measurement of geometric quantities Range: (0 - 3000) mm (0 - 220) ˚
PN-EN 1176-3:2017-12
The surface of the slide Method: test with samplers
PN-EN 1176-3:2017-12
Free space
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-3:2017-12
Free space
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-3:2017-12
Marking Method: sensory method PN-EN 1176-3:2017-12
Wersja strony: A
Edition no 12,15.07.2021 15/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Playground equipment and
surfacing - Part 4: Additional specific safety requirements and test methods for cableways
The design and mounting knots of the carrier rope
Method: sensory method
PN-EN 1176-4+AC:2019-03
Thrust bumpers
Measurement of geometric quantities Range: (0 - 220) ˚
PN-EN 1176-4+AC:2019-03
Crane
Method: sensory method PN-EN 1176-4+AC:2019-03 Suspension assembly
Method: sensory method
PN-EN 1176-4+AC:2019-03
Cable cars arranged in parallel Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-4+AC:2019-03
Handles
Testing with samplers
Measurement of geometric quantities Range: (0 - 160) mm
PN-EN 1176-4+AC:2019-03
Speed
Measurement of time and geometrical quantities, calculations
Range: (0 - 20,000) mm
PN-EN 1176-4+AC:2019-03
Free fall height
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-4+AC:2019-03
Ground clearance Measurement of force and geometrical quantities
Range: (0 - 1000) N (0 - 3000) mm
PN-EN 1176-4+AC:2019-03
Support rope height
Measurement of geometric quantities Range: (0 - 20,000) mm
PN-EN 1176-4+AC:2019-03
Fall area and impact surface
Measurement of geometric quantities Range: (0 - 20,000) mm
PN-EN 1176-4+AC:2019-03
Marking
Method: sensory method PN-EN 1176-4+AC:2019-03
Wersja strony: A
Edition no 12,15.07.2021 16/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Playground equipment and
surfacing - Part 6: Additional specific safety requirements and test methods for rocking
equipment
Free fall height
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-6+AC:2019-03
Tilting the seat / standing position Measurement of force and geometrical quantities Range:
(0 - 1000) N (0 - 3000) mm (0 - 220) ˚
PN-EN 1176-6+AC:2019-03
Jamming, crushing
Testing with samplers PN-EN 1176-6+AC:2019-03 Traffic braking
Method: sensory method
PN-EN 1176-6+AC:2019-03
Footrests
Testing with samplers
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-6+AC:2019-03
Hand rests
Testing with samplers
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-6+AC:2019-03
Side view profiles Testing with samplers
PN-EN 1176-6+AC:2019-03
Deadlock
Testing with samplers
Measurement of geometric quantities Range: (0 - 3000) mm (0 - 220) ˚
PN-EN 1176-6+AC:2019-03
Fall space
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-6+AC:2019-03
Lateral deflection (type 1) Measurement of force and geometrical quantities
Range: (0 - 1000) N (0 - 3000) mm
PN-EN 1176-6+AC:2019-03
Rotation around the vertical axis (type 3A)
Measurement of force and geometrical quantities Range: (0 - 1000) N (0 - 3000) mm (0 - 220) ˚
PN-EN 1176-6+AC:2019-03
Total Movement Range (Type 4)
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-6+AC:2019-03
Free fall height (type 6)
Measurement of geometric quantities Range: (0 - 3000) mm (0 - 220) ˚
PN-EN 1176-6+AC:2019-03
Marking
Method: sensory method PN-EN 1176-6+AC:2019-03
Edition no 12,15.07.2021 17/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Playground equipment and
surfacing - Part 11: Additional specific safety requirements and test methods for spatial network
Fall space
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 1176-11:2014-11
Mesh sizes in three-dimensional flat nets
Measurement of geometric quantities calculations
Range: (0 - 3000) mm
PN-EN 1176-11:2014-11
Protection against injuries in the fall area
Measurement of geometric quantities calculations
Range: (0 - 3000) mm
PN-EN 1176-11:2014-11
Convergent elements Testing with testers, force measurement
Range: (0 - 3000) mm (0 - 1000) N.
PN-EN 1176-11:2014-11
Permanently installed outdoor fitness equipment - Safety requirements and test methods
Structural strength
Method: strength test of structural elements
PN-EN 16630:2015-06 PN-EN 1176-1:2017-12 Finishing the device
Testing with samplers
Measurement of geometric quantities Range: (0 - 160) mm
PN-EN 16630:2015-06
Surfaces that can be walked on Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 16630:2015-06
Moving parts
Testing with samplers
Measurement of geometric quantities Range: (0 - 160) mm (0 - 220) ˚
PN-EN 16630:2015-06
Protection against jamming Testing with samplers
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 16630:2015-06
Loads and resistors
Method: sensory method PN-EN 16630:2015-06 Regulating and blocking mechanisms
Method: sensory method
PN-EN 16630:2015-06 Accessibility of entry / exit
Method: sensory method
PN-EN 16630:2015-06 Connections
Method: sensory method
PN-EN 16630:2015-06 Wear parts
Method: sensory method PN-EN 16630:2015-06 Grip / grip
Measurement of geometric quantities Range: (0 - 160) mm
PN-EN 16630:2015-06
Ropes Measurement of geometric quantities
Range: (0 - 3000) mm
PN-EN 16630:2015-06
Chains
Testing with samplers
PN-EN 16630:2015-06 Surfaces and spaces
Measurement of geometric quantities Range: (0 - 20,000) mm
PN-EN 16630:2015-06
Free fall height
Measurement of geometric quantities Range: (0 - 20,000) mm
PN-EN 16630:2015-06
Marking Method: sensory method PN-EN 16630:2015-06
Wersja strony: A
Edition no 12,15.07.2021 18/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Sports and recreational equipment
- Parkour equipment - Safety requirements and test methods
Structural strength
Method: strength test of structural elements
PN-EN 16899:2017-02
Childproof accessibility
Measurement of geometric quantities Calculations
Range: (0 - 3000) mm
PN-EN 16899:2017-02
Finishing the device Testing with samplers
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 16899:2017-02
Parkour beams and rails
Measurement of geometric quantities Range: (0 - 3000) mm (0 - 220)˚
PN-EN 16899:2017-02
Closed passages
Measurement of geometric quantities Range: (0 - 3000) mm (0 - 220) ˚
PN-EN 16899:2017-02
Protection against injuries during movement and falling
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 16899:2017-02
Spacing
Testing with samplers
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 16899:2017-02
Protection against jamming Testing with samplers
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 16899:2017-02
Free fall height
Measurement of geometric quantities Range: (0 - 3000) mm
PN-EN 16899:2017-02
Marking
Method: sensory method
PN-EN 16899:2017-02
Edition no 12,15.07.2021 19/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Stationary training equipment —
Part 1: General safety
requirements and test methods
Stability
Functional tests at an inclination of 10˚
PN-EN ISO 20957-1:2014-02 Outdoor construction
Testing with probes, visual inspection, tactile tests
User imprisonment
Visual inspection and functional tests Regulation and lock mechanisms Functional tests, visual inspections Strength of ropes, belts, chains and slings
Tensile strength test Rope and belt guides Functional tests Flywheels
Testing with samplers Handles
Functional tests, secure mounting Weighting equipment
Force measurement
Heart rate measuring system Function check
Internal and external load Load test
Marking Inspection Stationary training equipment —
Part 4: Strength training benches, additional specific safety
requirements and test methods
Geometric dimensions Linear measurement
PN-EN ISO 20957-4:2017-03 Inspection
Functional tests
Rotary stability of the barbell
Rotary and longitudinal stability of the bench
Stationary training equipment — Part 5: Stationary exercise bicycles and upper body crank training equipment, additional specific safety requirements and test methods
Geometric dimensions PN-EN ISO 20957-5:2017-03 Inspection
Tactile tests Functional tests Temperature rise
Gear components and rotating components
Testing with samplers Internal load
Load test Seat tilt Load test Stability
Functional tests at an inclination of 10˚
Stationary training equipment — Part 9: Elliptical trainers, additional specific safety requirements and test methods
Geometric dimensions PN-EN ISO 20957-9:2017- 03+A1:2019-07
Inspection Functional tests
Squeezing and crushing places Testing with samplers
Temperature rise Internal load Load test Stability
Functional tests at an inclination of 10˚
Wersja strony: A
Edition no 12,15.07.2021 20/22 Noise Tests Laboratory
Tested objects/Group of objects Tested features and test/
measurement methods Standards and/or documented testing procedures Work environment - noise Acoustic pressure level
Range: from 23 to 137 dB Reference method
PN-EN ISO 11202:2012
Acoustic power level
Acoustic energy level (calculated) Machines and equipment - noise Equivalent noise level A
Range: (23 to 137) dB Method: direct measurement
PN-EN ISO 3746:2011+Ap1:2017- 09
Acoustic power level
Acoustic energy level (calculated) Work environment – Human
exposure to mechanical vibrations
Whole-body vibration
Effective frequency-weighted vibration acceleration
Range: (0.003 – 700) m/s2
Measurement method: direct
PN-EN 14253+A1:2011
Daily exposure expressed by energetically equivalent 8-hour exposure
to the effective frequency-weighted vibration acceleration, dominating among
the vibration accelerations, determined for
three directional components, taking into
account adequate coefficients (1.4awx, 1.4awy, awz).
30-minute and shorter exposure expressed by the effective frequencyweighted vibration acceleration,
dominating among the vibration accelerations, determined for three directional components, taking into account adequate coefficients (1.4awx, 1.4awy, awz) (obtained by
calculations).
Wersja strony: A
Edition no 12,15.07.2021 21/22 Tested objects/Group of objects Tested features and test/
measurement methods
Standards and/or documented testing procedures Work environment – Human
exposure to hand-transmitted mechanical vibrations
Effective frequency-weighted vibration acceleration
Range: (0.01 – 700) m/s2
Measurement method: direct
PN-EN ISO 5349-2:2004
Daily exposure expressed by energetically equivalent 8-hour exposure
to the vector sum of effective frequencyweighted
vibration accelerations
determined for three directional components (ahwx, ahwy, ahwz).
30-minute and shorter exposure expressed by the vector sum of effective
frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy,
ahwz)
(obtained by calculations).
Wersja strony: A
Edition no 12,15.07.2021 22/22
HOLOGRA MHOLOG RAM HOLOGRA
MHOLOG
List of changes
Scope of Accreditation No.AB 1340
Change status: original version - A