• Nie Znaleziono Wyników

Longitudinal antero-inferior approach for ultrasound-guided hip joint injection

N/A
N/A
Protected

Academic year: 2022

Share "Longitudinal antero-inferior approach for ultrasound-guided hip joint injection"

Copied!
2
0
0

Pełen tekst

(1)

e231

Longitudinal antero-inferior approach for ultrasound-guided hip joint injection

Letter to the editor

Cite as: Yildizgoren MT: Longitudinal antero-inferior approach for ultrasound-guided hip joint injection.

J Ultrason 2020; 20: e231–e232. doi: 10.15557/JoU.2020.0041.

© Polish Ultrasound Society. Published by Medical Communications Sp. z o.o. This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial- NoDerivatives License (CC BY-NC-ND). Reproduction is permitted for personal, educational, non-commercial use, provided that the original article is in whole, unmodified, and properly cited.

Longitudinal antero-inferior approach for ultrasound-guided hip joint injection

Mustafa Turgut Yildizgoren

Fizikon Medical Center, Department of Physical Medicine and Rehabilitation, Konya, Turkey Correspondence: Mustafa Turgut Yildizgoren, MD, Fizikon Medical Center, Department of Physical Medicine and Rehabilitation, Konya, Turkey; tel.: 90 332 353 6900, fax: 90 332 353 6900, e-mail: ftr.mustafaturgut@hotmail.com

DOI: 10.15557/JoU.2020.0041 Submitted:

21.05.2020 Accepted:

29.07.2020 Published:

28.09.2020

Step 1. The curved array transducer is placed on the lateral third of the inguinal ligament in the anterior oblique plane over the anterior femoral neck (Fig. 1). At this level, the anterior synovial recess, which is the target for the injec- tion, is identified (Fig. 2A). Effusion can be demonstrated as hypoechoic fluid.

Step 2. The transducer is moved cranially, from the lateral edge of the thigh to the medial, until the femoral head is seen as a hyperechoic curved line. At this level, the ante- rior hip labrum may also be seen as a triangular structure (Fig. 2A).

Step 3. The injection site is caudal to the transducer, and the target is the anterior recess. The needle is introduced at an angle of about 45 degrees to the horizontal skin plane until the needle tip hits the anterior recess (Fig. 2B).

Owing to the deep location of the hip joint, landmark- guided (blind) injections suffer from a lack of accuracy, in addition to the possibility of damage to the neurovascular bundles in proximity to the joint. In the literature, the accu- racy rates of landmark-guided injections vary from 50% to 80%, depending on the method used for treatment. The lat- eral approach is safer than the anterior approach for intra- articular injection of the hip using anatomic landmarks. In this way, there is less risk of nerve damage, and the success rate of intra-articular injections increases(1,2).

The accuracy of injections with ultrasound guidance has been reported to range from 97% to 100%. Intra-articular hip injections are used for both diagnostic and therapeu- tic purposes, such as fluid aspiration or injection of medi- cations(3). There are two injection techniques: an indirect approach (free-hand technique) and a direct approach (real time, device-guided). There are several approaches, the authors’ preferred one being the longitudinal antero- inferior approach(4).

The target is the anterior synovial recess underneath the joint capsule at the femoral head-neck junction. A 22-gauge spinal needle is inserted in-plane from lateral to medial to the junction between the femoral head and neck. The needle is inserted through the fat tissue, rectus femoris, iliopsoas muscle and capsule until bone contact is made, and is then withdrawn 1 mm(5,6) . The spread of the injec- tate is monitored in real time throughout the procedure;

this is important to make sure that the injectate is spread within the joint space.

We suggest a US-guided approach for intra-articular hip injection as the most practical method. There are three simple steps for the injection: first, the patient is placed in the supine position, with the hip in the neutral position, and a pillow under the knee may provide support comfort.

Fig. 1. Photograph demonstrating correct transducer and needle po- sition

(2)

e232

J Ultrason 2020; 20: e231–e232 Dongyan Cai, Size Wu, Ya Li, Qingfang Chen

The US-guided intra-articular hip injection technique has been shown to have very high rates of accuracy in correct needle placement into the anterior recess for subsequent hip injection. US imaging can also effectively provide real- time needle guidance for hip joint injections, completely avoiding neurovascular injury.

Conflict of interest

Author does not report any financial or personal connections with other persons or organizations, which might negatively affect the contents of this publication and/or claim authorship rights to this publication.

Fig. 2. A. Ultrasound image (longitudinal oblique plane) showing the anterior recess (*) (asterisk), the joint capsule (JC), the acetabulum (A), the femoral head (FH), and B. Longitudinal antero-inferior approach (a) and needle path (N)

References

1. Leopold SS, Battista V, Oliverio JA: Safety and efficacy of intraarticular hip injection using anatomic landmarks. Clin Orthop Relat Res 2001: 192–197.

2. Masoud MA, Said HG: Intra-articular hip injection using anatomic sur- face landmarks. Arthrosc Tech 2013; 2: e147–149.

3. Narouze SN (ed.): Atlas of Ultrasound-Guided Procedures in Interven- tional Pain Management. Springer 2018: 280–282.

4. Cosmina MM: Ultrasound guided hip injection techniques. In: Qian Chen (ed.): Osteoarthritis – Diagnosis, Treatment and Surgery, InTech 2012: 349.

5. Peng PW: Ultrasound-guided interventional procedures in pain medicine:

a review of anatomy, sonoanatomy, and procedures. Part IV: hip. Reg Anesth Pain Med 2013; 38: 264–273.

6. Smith J, Hurdle MF, Weingarten TN: Accuracy of sonographically guided intra-articular injections in the native adult hip. J Ultrasound Med 2009;

28: 329–335.

A B

Cytaty

Powiązane dokumenty

The obtained stress and strain distribution for the assigned materials prove that the ceramic elements in the analysed system will not be damaged.. Statement of the maximum values

prawę zauważono w takich wymiarach stanu zdrowia, jak energia życiowa, sprawność ruchowa, ból oraz funkcjonowanie fizyczne. Badając związek między płcią a jakością

High- frequency ultrasound guidance was used to monitor such parameters as the thickness of the dermis (DermaMed, Dramiński S.A.) or the subcutaneous tissue (Philips Epiq 5, USA)..

Conclusions: Literature to date concludes that intra-articular platelet-rich plasma injections of the hip, performed under ultrasound guidance to treat hip osteoarthritis, are

High-volume image-guided injection is a relatively new technique where a high volume of liquid is injected between the anterior aspect of the Achilles tendon and the Kager’s fat

We describe a new method (Gaurav-Botchu technique) to access the target zone (between the coracohumeral ligament and the long head of the biceps tendon) via a medial to

Conclusions: The 10-year experience presented in this study as well as literature reports prove that percutaneous ultrasound-guided thrombin injection is an effective and

The aim of the study is to perform an analysis of the stress and strain in hip joint of the children with the imbalance in muscle forces due to adductors spasticity