Bridging therapy: coil and polymer embolisation of a ruptured penetrating aortic ulceration of the visceral aorta

N/A
N/A
Protected

Academic year: 2022

Share "Bridging therapy: coil and polymer embolisation of a ruptured penetrating aortic ulceration of the visceral aorta"

Copied!
1
0
0

Pełen tekst

(1)

www.kardiologiapolska.pl

Kardiologia Polska 2015; 73, 7: 569; DOI: 10.5603/KP.2015.0125 ISSN 0022–9032

Studium przypadku / CliniCal Vignette

Address for correspondence:

Krzysztof Korzeniowski, MD, 2nd Department of Clinical Radiology, Medical University of Warsaw, ul. Banacha 1A, 02–097 Warszawa, Poland, e-mail: kkorzeniowski85@gmail.com

Conflict of interest: Mikołaj Wojtaszek and Rafał Maciąg — speaker and trainer for Covidien

Bridging therapy: coil and polymer embolisation of a ruptured penetrating aortic ulceration

of the visceral aorta

Embolizacja pęknięcia aorty za pomocą polimeru i spiral: leczenie pomostowe Mikołaj Wojtaszek

1

, Rafał Maciąg

1

, Krzysztof Korzeniowski

1

, Ireneusz Nawrot

2

, Olgierd Rowiński

1

12nd Department of Clinical Radiology, Medical University of Warsaw, Warsaw, Poland

2Department of General, Vascular, and Transplantation Surgery, Medical University of Warsaw, Warsaw, Poland

A 74-year-old woman complaining of fatigue and abdominal pain that increased during physical examination was referred to our hospital. She was conscious but hypotensive with a haemoglobin level of 8.8 g/dL. Creatinine level of 2.2 mg/dL suggested concomitant acute renal insufficiency. Abdominal contrast-enhanced computer tomography (CECT) revealed a large haematoma (132 × 118 × 80 mm) with active extravasation of contrast medium at the level between the celiac trunk and superior mesenteric artery, filling the retroperitoneal space directly adjacent to the right kidney (Fig. 1). A pen- etrating aortic ulceration was considered the most probable underlying cause of rupture. Comorbidities disqualified the patient from surgical open repair and she was referred to the radiology suite for a non-standard emergency endovascular procedure. The procedure was performed under local anaesthesia using bilateral femoral access (10 F and 6 F sheaths).

Aortography confirmed CECT findings (Fig. 2). Through the perforation, the retroperitoneal space was catheterised using a 5 F Cobra 1 catheter (Cook Medical Europe) and “jailed” with a SINUS XL 30 × 62 mm self-expandable stent (OptiMed) at the rupture level. This enabled safe filling of the retroperitoneal space with 18 pushable Nester coils (Cook Medical Europe) and 13 detachable Concerto coils (Covidien) of various sizes. Coil embolisation was followed by a 3-ampule injection of the liquid embolic agent Onyx 34 (Covidien) while protecting the potential polymer reflux with a 33-mm occlusion balloon (Equalizer, Boston Scientific). Control angiography revealed no sign of extravasation and preserved blood flow to the visceral arteries (Fig. 3). The patient was transferred to the intensive care unit for 4 days of observa- tion. During her stay she regained kidney function and was transferred for further observation to an internal medicine ward to leave the hospital 12 days after the initial procedure. Bearing in mind that the performed procedure was only a bridging therapy, a branched endoprosthesis was ordered and a secondary aortic intervention was scheduled. Unfor- tunately, the patient was never readmitted for the procedure because she died 5 weeks after the primary procedure and just 1 week before the scheduled reintervention, with symptoms strongly suggesting another rupture at the sealing level.

In conclusion, for patients with a ruptured aorta and with no means of traditional open or endovascular repair, sealing of the rupture site with embolisation polymers and coils can provide a bridging therapy before a prompt and definitive treatment can be established.

Figure 1. The calcified abdominal aorta and rup- ture with large haematoma in contrast-enhanced computer tomography

Figure 3. Final aortography sho- wed no sign of extravasation Figure 2. The retroperitoneal

space catheterised with a Cobra 1 catheter. Angiography demonstra- ted extravasation

Cytaty

Powiązane dokumenty

Figure 1 a – transmural hypoattenuation in the inferolateral wall of the left ventricle (arrow) detected by computed tomography in a patient with previous myocardial infarction; B

Advanced age, male gender, the presence of diabetes, high initial creatinine, uric acid and phosphate levels, a low GFR and a high ALP level were found to be predictors of

The nurse should be able to step up to the patient’s-initiated con- tact and direct it so that it flourishes and re- sults in the patient’s positive attitude towards the disease,

Variations of the renal arteries were observed in 83 (41.3%) patients, anomalies of the celiac trunk in 9 patients (4.5%), including variations of the superior mesenteric artery in

W nowej metodzie autorzy niniejszej pracy upatrywali możliwość dokładniejszej diagnostyki guzów nadnerczy oraz poprawę swoistości badania ultrasonograficznego w rozpoznawaniu

Introduction: The aim of this study was to analyze the diagnostic potential of contrast enhanced ultrasound (CEUS) for the reco- gnition of focal lesions of the spleen and liver

Girlich C, Schacherer D, Jung EM et al: Comparison between a clinical activity index (Harvey-Bradshaw-Index), laboratory inflammation markers and quantitative assessment of bowel

Purpose : The purpose of this study was to evaluate magnetic resonance imaging (MRI)-pathology concordance of tumour size in patients with invasive breast carcinoma, with an