184 Advances in Interventional Cardiology 2017; 13, 2 (48)

Image in intervention

Corresponding author:

Zefferino Palamà MD, Cardiology Unit, Policlinico Casilino, via Casilina, 1049 00100 Rome, Italy, phone: +39 3483153676, e-mail: zefferino.palama@icloud.com

Received: 14.12.2016, accepted: 18.01.2017.

Carotid sinus hypersensitivity syncope: is there a possible alternative approach to pacemaker implantation in young patients?

Zefferino Palamà, Ermenegildo De Ruvo, Domenico Grieco, Alessio Borrelli, Luigi Sciarra, Leonardo Calò

Cardiology Unit, Policlinico Casilino, Rome, Italy

Adv Interv Cardiol 2017; 13, 2 (48): 184–185 DOI: https://doi.org/10.5114/pwki.2017.67993

Carotid sinus hypersensitivity (CSH) is frequently found in about one third of elderly patients with syn- cope and trauma, but it may also be a common finding in younger patients. Pacemaker implantation is recom- mended in patients with recurrent syncope once CSH has been recognised. Cardioneuroablation (CNA) has been re- ported as an effective treatment in cardioinhibitory syn- cope [1, 2]. A few reports are currently available in neu- rally mediated syncope and functional atrioventricular block [3, 4], but no previous experiences are available in carotid sinus hypersensitivity syncope.

A 42-year-old female patient, with normal heart and no relevant medical history, was referred to our centre for recurrent CSH syncope. As the patient refused PM implantation, autonomic nervous system modulation through CNA was proposed. At the basic EP study normal atrioventricular conduction parameters (AH 68 ms, HV 50 ms) were documented; during CSM a sinus arrest of up to 5.4 s occurred. Electroanatomical mapping of the right atrium with identification of phrenic nerve course was performed (Figure 1 A). Anterior right CNA (35 W, 43°C, 2 min and 40 s of RF delivery) at the level of the septal as- pect of the superior vena cava determined a shortening of the basal sinus cycle length (from 975 ms to 730 ms).

Vagal stimulation by manual CSM did not cause any pause. After 20 min, a  new CSM showed suprahisian

atrioventricular block with normal HV (RR max of 2608 ms) (Figure 1 B). Inferior right CNA (35 W, 43°C, 1 min and 30 s of RF delivery) posterior to the coronary sinus os- tium was performed, in a region previously reported to be involved in AV conduction neuromodulation (located between the inferior vena cava and the right/left atrium) [1–3]. At CSM after RF and after 30 min of observation no longer pathological pauses were documented (RR max 1.4 s). Shorter AV conduction intervals were observed (AH 48 ms, HV 50 ms). At 6-month follow-up the patient is still asymptomatic for syncope and dizziness.

Ablation lesions were performed using an anatomical approach (without AF-Nest mapping); no pharmacologi- cal test was performed to confirm the denervation; only right atrial CNA was performed in order to minimize the risk of complications; a longer follow-up period is needed to confirm ablation results.

The CNA restricted to the right atrium, if properly standardized, could be an attractive and safer alternative to PM implantation to treat CSH syncope, especially in younger patients who are more vulnerable to medium- and long-term complications related to device implanta- tion.

Conflict of interest

The authors declare no conflict of interest.

(2)

Zefferino Palamà et al. A new approach to carotid sinus hypersensitivity syncope

185

Advances in Interventional Cardiology 2017; 13, 2 (48) References

1. Pachon JC, Pachon EI, Pachon JC, et al. “CNA”: new treatment for neurocardiogenic syncope, functional AV block and sinus dysfunction using catheter RF-ablation. Europace 2005; 7: 1-13.

2. Pachon JC, Pachon EI, Cunha Pachon MZ, et al. Catheter abla- tion of severe neurally meditated reflex (neurocardiogenic or vasovagal) syncope: cardioneuroablation long-term results. Eu- ropace 2011; 13: 1231-42.

3. Pachon MJC, Pachon M EI, Lobo TJ, et al. Syncopal high-degree AV block treated with catheter RF ablation without pacemaker implantation. Pacing Clin Electrophysiol 2006; 29: 318-22.

4. Fukunaga M, Wichterle D, Peicl P, et al. Differential effect of ganglionic plexi ablation in a  patient with neutrally mediated syncope and intermittent atrioventricular block. Europace 2017;

19: 119-26.

Figure 1. A – Electroanatomical map of the right atrium with identification of phrenic nerve course and lesions set, B – suprahissian atrioventricular block with normal HV after right anterior CNA

A B

Cytaty

Powiązane dokumenty

Superior vena cava (SVC) selective angiography (left) showing shunt between right and left atria through the sinus venosus atrial septal defect (SVASD) and left anterior

Pacemaker implantation due to documented bradycardia was performed according to the ESC.. Baseline demographic and clinical characteristics of the study population before

Palce pałeczkowate obserwuje się stosunkowo często u chorych na przewlekłą postać AZPP i objaw ten może być markerem klinicznego pogorszenia (5).. Pięcioro naszych chorych

The overall prognosis in the general population is by large determined by the underlying presence and severity of a given cardiac disease, but a given underlying cardiac disease

The causes of TLOC were known satisfactorily in 539 patients and included seizures (n = 102; complex partial epilepsy [50 patients] and primary generalized epile- psy [52 patients])

Conclusions: Right ventricular bifocal pacing in patients with cardiac resynchronization therapy indication and unsuccessful left ventricular lead placement seems to be a

I would take issue with this definition as it is highly dependent on how the device is programmed: too short an AV delay that usurps control from the nor- mal AV conduction system

The purpose of the present study was to ex- amine pacemaker dependency (PD) in paced pa- tients during long-term follow-up and to evaluate the difference between patients with