www.kardiologiapolska.pl

Kardiologia Polska 2015; 73, 2: 129; DOI: 10.5603/KP.2015.0018 ISSN 0022–9032

Studium przypadku / CliniCal Vignette

Address for correspondence:

Michał Lelek, MD, 1st Department of Cardiology, SPSK nr 7, Medical University of Silesia, Upper Silesian Medical Centre, ul. Ziołowa 45/47, 40–635 Katowice, Poland, e-mail: michlel@wp.pl

Conflict of interest: none declared

Figure 1. Fluoroscopy and echocardiography; A. Severe aortic bioprosthesis stenosis; B. Corevalve positioned at bioprosthesis level. Visible bioprosthetic ring (white arrow); C. Partially released Corevalve prosthesis (white arrow).

Inappropriate position over bioprosthetic ring; D. Recaptured Corevalve prosthesis; E. Early phase of second deployment; F. Corevalve completely released; G. Visible Corevalve prosthesis in left ventricular outflow track and ascending aorta (white arrows)

A

A next-generation self-expandable valve implantation in a patient with

failed aortic bioprosthesis

Przezskórna implantacja samorozprężalnej zastawki nowej generacji u pacjenta ze zdegenerowaną bioprotezą aortalną

Michał Lelek

1

, Radosław Parma

2

, Michał Krejca

3

, Piotr Pysz

4

, Andrzej Ochała

5

11st Department of Cardiology, Medical University of Silesia, Upper Silesian Medical Centre, Katowice, Poland

23rd Department of Cardiology, Medical University of Silesia, Upper Silesian Medical Centre, Katowice, Poland

3Department of Cardiac Surgery, Medical University of Silesia, Upper Silesian Medical Centre, Katowice, Poland

42nd Department of Cardiology, Medical University of Silesia, Upper Silesian Medical Centre, Katowice, Poland

5Department of Invasive Cardiology, Medical University of Silesia, Upper Silesian Medical Centre, Katowice, Poland

A 72-year-old woman with a history of aortic valve replacement with a 21 mm Sorin Pericarbon More bioprosthetic valve (Sorin, Sallugia, Italy) associated with coronary artery bypass grafting (left internal mammary artery-left anterior descending artery [LIMA-LAD], aorta-right coronary artery [Ao-RCA]) in 2007 was admitted to our hospital on account of recurrent symptoms of congestive heart failure NYHA class III. Her medical history was significant for arterial hypertension, diabetes and renal insufficiency with an estimated glomerular filtration rate of 40 mL/min. Echocardiography revealed a degener- ated aortic bioprosthesis with maximal and mean pressure gradients of 133 and 73 mm Hg, respectively and a calculated aortic valve area of 0.5 cm2 with a depressed left ventricular ejection fraction of 40% (Fig. 1A). Coronary angiography revealed significant stenosis of LAD and RCA; the LIMA and Ao-RCA grafts were patent. Peripheral angiography dem- onstrated wide iliac and common femoral arteries (CFA) suitable for transcatheter aortic valve replacement (TAVI). Risk scores were calculated: Euroscore II was 14% and STS mortality score was 22%. Taking into account the high surgical risk, the Heart Team decided to perform a valve-in-valve TAVI. The procedure was performed on 4 November 2014 under general anaesthesia. The right CFA was surgically exposed. After placing a pigtail catheter in the ascending aorta via the left CFA artery, the right CFA was punctured

and 12-F sheath was initially used to insert a stiff guidewire into the left ventricle through the degenerated bioprosthesis. We decided to use a new generation Corevalve Evolut R prosthesis (Medtronic, Minneapolis, MN, USA) which has a lower delivery profile equivalent to a 14 Fr system and offers the option to recapture and reposition during the deployment phase, if needed. The Corevalve Evolut R 23 mm was inserted and positioned at aortic bioprosthesis level (Fig. 1B). The fluoroscopically visible bioprosthetic ring facilitated the identification of the best radiographic projection. During the first at- tempt, the prosthesis was positioned too high (Fig. 1C). The valve was easily recaptured in the ascending aorta and implanted once again in the optimal position with excellent angiographic and echocardiographic results (Fig. 1D–G). Further in-hospital course was uneventful, and the patient was discharged on the seventh day after TAVI.

F G

E

B C D

Cytaty

Powiązane dokumenty

dergoing aortic valve repair (BAV > TAV) suggests that many patients with AI are still considered for aortic valve repair, except for young patients with a congenital BAV.

In a sta- ble patient, the approach is to control the posi- tion of a stiff guidewire, verify the valve shape and re-balloon in the case of distortion, as well as increase

Computed tomography showed an aortic annulus area of 293 mm 2 and significant abdominal aortic stenosis with severe calcification (indicated with a yel-.. low

In addition, initial clinical data on the first 20 patients with severe aortic stenosis, who underwent isolated aortic valve replacement (AVR) with RESILIA™ tissue valves,

Feasibility and outcomes of transcatheter aortic valve implantation in high-risk patients with stenotic bicuspid aortic valves.. Zegdi R, Khabbaz Z, Ciobotaru V

Computed tomography angiography confirmed aortic dissection — Stanford type A, with dissected aortic arch, brachiocephalic trunk, both common carotid arteries, and the left

Conclusions: This early clinical experience using an aortic bioprosthetic valve treated with a novel anti-calcification tissue processing technology demonstrated excellent

Edwards Sapien 3 prosthesis is a novel de- vice for TAVI procedures to improve results of valve implantation mainly by reducing the risk of paravalvular leaks due to a new design