Studium przypadku / CliniCal Vignette

Dual guiding catheter approach for the

treatment of massive coronary artery perforation

Równoczesne zastosowanie dwóch cewników prowadzących w leczeniu masywnej perforacji tętnicy wieńcowej

Michał Lelek, Tomasz Bochenek, Katarzyna Mizia-Stec

1st Department of Cardiology, Medical University of Silesia, Upper Silesian Medical Centre, Katowice, Poland A dual catheter approach is routinely used during percutaneous coronary in-

tervention of coronary chronic total occlusion. However, this simple technique could be used during life-threatening complications in the cath lab. We present a case in which a dual guiding catheter approach was the only possible technique to treat coronary artery perforation leading to patient haemodynamic collapse.

A 64-year-old woman was admitted to our hospital because of severe chest pain with electrocardiogram pattern of inferior ST segment elevation myocardial infarction. Immediately performed coronary angiography showed the culprit lesion in the mid portion of the circumflex artery (CX) with TIMI 2 flow (Fig. 1).

An Amplatz left 2 (AL2) 6 F Launcher guiding catheter was inserted in the left main (LM) and a coronary wire was positioned in the distal CX. The culprit lesion was directly stented with a 4.0 × 15 mm bare metal stent at 12 atm. Control angiography revealed coronary artery perforation type III at the site of the stent with massive contrast extravasation (Fig. 2). Immediately, a 4.0 × 15 mm bal- loon at 4 atm was inflated inside the stent and protamine sulphate was given to reverse anticoagulation. After prolonged 2 × 15 min balloon inflation, perfora- tion was still present (Fig. 3). Control echocardiography (ECHO) at this stage revealed no pericardial effusion. Based on normal ECHO findings, the operator decided to remove the balloon from CX and implant a 3.5 × 19 mm stent graft (Jostent, GraftMaster). According to the manufacturer, a minimum 6 F guiding catheter is recommended for stent graft placement, so the operator anticipated no problems with stent graft crossing. Unfortunately, it was impossible to insert the stent graft through AL2 guiding catheter. Once again, the balloon was in- serted and inflated in the CX. While the balloon was advancing, the patient lost consciousness and systolic pressure dropped from 120 to 60 mm Hg. High rate infusion of fluids and dopamine were given. ECHO confirmed tamponade with 15 mm free space behind right ventricle so the pig-tail

catheter was inserted into the pericardium and 240 mL of blood was aspirated. A second 7 F guiding catheter was inserted in the LM from the contralateral femoral artery and a second wire was advanced to the distal portion of the CX. Through a 7 F guiding catheter the stent graft was easily placed close to the LM (Fig. 4).

The balloon was removed from the CX and the stent graft was implanted at 18 atm inside the stent. A final angiogram showed a very good angiographic result with no signs of vessel perforation or contrast leakage (Fig. 5). Further in-hospital course was uneventful, and the patient was discharged on the 5th day.

Address for correspondence:

Michał Lelek, MD, 1st Departmentof of Cardiology, SPSK nr 7, Medical University of Silesia, Upper Silesian Medical Centre, ul. Ziołowa 45/47, 40–635 Katowice, Poland, e-mail: michlel@wp.pl

Conflict of interest: none declared

Figure 5. Final result

Figure 1. Culprit lesion in circumflex artery

Figure 4. Stent graft in distal part of 7 F guiding catheter (arrow)

Figure 2. Perfora- tion with massive contrast extrava- sation

Figure 3. Perfora- tion still present after prolonged balloon inflation

Cytaty

Powiązane dokumenty

Principal findings from this work, evaluating performance of an angiographic 3DR software in relation to its application for CAAE characteristics, are the following: (1) CAAE

The clinical and angiographic data of all pa- tients were reviewed retrospectively. Demograph- ics of the patients and angiographic data such as radial artery site, total

Also important in the development of CAP are se- veral angiographic factors including coronary artery calcification, lesion tortuosity, and type C lesions and lesion related

Coronary angiography showed a patent left main coronary artery and chronic total occlusions (CTOs) of the following vessels: mid segment of the left anterior descending artery

1 Department of Congenital Heart Defects and Paediatric Cardiology, SMDZ in Zabrze, Medical University of Silesia in Katowice, Silesian Centre for Heart Diseases, Zabrze, Poland..

1 1 st Department of Cardiology, Medical University of Silesia, Upper Silesian Medical Centre, Katowice, Poland.. 2 3 rd Department of Cardiology, Medical University of

Primary Stenting of Totally Occluded Native Coronary Arteries II (PRISON II): a randomized comparison of bare metal stent implantation with sirolimus-eluting stent implantation for

Acute air embolism has been described during central venous cannulation, but it may also occur during catheter removal in a spontaneously breathing patient.. We describe an episode of