• Nie Znaleziono Wyników

PDF stworzony przez wersję demonstracyjną pdfFactory Pro www.pdffactory.pl/

N/A
N/A
Protected

Academic year: 2021

Share "PDF stworzony przez wersję demonstracyjną pdfFactory Pro www.pdffactory.pl/"

Copied!
1
0
0

Pełen tekst

(1)

Vibration syndrome diagnosis using cooling test verified by computerised photoplethysmography

ANDRZEJ DYSZKIEWICZ, MICHAŁ TENDERA*

Computer Science Department, University of Silesia, Sosnowiec; Rehabilitation Department

"VIS"; Laboratory of Biotechnology, Poland; *3rd Division of Cardiology, Silesian School of Medicine, Poland

Acta Bioeng Biomech, 2004; 6(2):33-41

Abstract: This study addresses itself to the problem of vibration syndrome diagnosis by means of photople-thysmography. The measurement was performed on a small area on the finger-tip plexus in which many arteriovenous anastomoses are present. In the opinion of many authors, flow disorders in this area are more typical of developing vibration syndrome than changes in the microvessels. Cooling test was then performed and it was verified both visually and using the computer method, allowing the functional measurement of the flow to be obtained. Computer method proved to be much more sensitive than tradi-tional tests. The test proposed allows us to detect vascular disorders in the prodromal period and gives time for preventive measures to be taken.

Key words: vibration syndrome, microcirculation, computer diagnosis, cooling test, flow sensor modification, planimetric estimation

PDF stworzony przez wersję demonstracyjną pdfFactory Pro www.pdffactory.pl/

Cytaty

Powiązane dokumenty

According to the recommendations of the European Resuscitation Council, the clinical assessment of the location of the endotracheal tube should first be based on the observation

Abstract: A number of muscles which pull over the tibiofemoral joint (possessing maximally four kinematic degrees of freedom) is larger than necessary in order to produce

A program of investigations comprised an analysis of the state of stresses and strains in the mandible and stabilization of miniplates applying the holographic

The results showed that during axial compression there is a small increase in pressure following the introduction of bone graft when compared to the intact

Department of Anatomy and Biomechanics FTVS, Charles University, Prague; * Institute of Thermomechanics, Academy of Sciences of the Czech Republic, Prague, Czech Republic Acta

Department of Applied Mechanics, Biomechanical Laboratory, Budapest University of Technology and Economics; * Research Group of Structures, Hungarian Academy of

Our results show quite a complete picture of hemiparetic gait: a reduction of all the basic gait parameters; a reduction of joint excursions in the hip and knee on both

The selected kinematic parameter Xhip, (instantaneous hip displacement) varies little among the swimmers, whereas for the parameter k (describing the variation of