Application of miniature pressure transducers to the investigation of intradiscal pressure in the cervical spine

CELINA PEZOWICZ, BARBARA KACZMAREK, ROMUALD BĘDZIŃSKI

Division of Biomedical Engineering and Experimental Mechanics, Wroclaw University of Technology, Poland

Acta Bioeng Biomech, 2004; 6(2):23-32

Abstract: The method developed and used by the authors to measure intradiscal pressure is presented. We constructed 'needle' indicators fitted with miniature pressure transducers. Our analysis assessed the impact of stabilization on pressure in intervertebral discs adjacent to the stabilization area under compression and bending loads. The research was carried out on the post-mortem specimens of the cervical spine. The results showed that during axial compression there is a small increase in pressure following the introduction of bone graft when compared to the intact spine. On the other hand, bending has a major influence on the resultant pressure, depending on spinal level and the type of bending (flexion/extension). We have also concluded that, regardless of the type of load, in the discs above (the planned and then implemented) stabilization area, the pressure is lower than in discs located below.

Key words: intradiscal pressure, cervical spine, stabilization

PDF stworzony przez wersję demonstracyjną pdfFactory Pro www.pdffactory.pl/

Cytaty

Powiązane dokumenty

Abstract: A number of muscles which pull over the tibiofemoral joint (possessing maximally four kinematic degrees of freedom) is larger than necessary in order to produce

A program of investigations comprised an analysis of the state of stresses and strains in the mandible and stabilization of miniplates applying the holographic

Cooling test was then performed and it was verified both visually and using the computer method, allowing the functional measurement of the flow to be obtained.

Department of Anatomy and Biomechanics FTVS, Charles University, Prague; * Institute of Thermomechanics, Academy of Sciences of the Czech Republic, Prague, Czech Republic Acta

Department of Applied Mechanics, Biomechanical Laboratory, Budapest University of Technology and Economics; * Research Group of Structures, Hungarian Academy of

Our results show quite a complete picture of hemiparetic gait: a reduction of all the basic gait parameters; a reduction of joint excursions in the hip and knee on both

The selected kinematic parameter Xhip, (instantaneous hip displacement) varies little among the swimmers, whereas for the parameter k (describing the variation of

Wykonawca odpowiedzialny jest za prowadzenie robót zgodne z umową oraz za jakość stosowanych materiałów i wykonywanych robót, za ich zgodność z PB, wymaganiami ST,