(1)

Experimental and numerical method in biomechanical analysis of miniplate osteosynthesis

of mandible fracture

ANNA ZIĘBOWICZ, JAN MARCINIAK

Institute of Engineering Materials and Biomaterials, Silesian University of Technology, Poland Acta Bioeng Biomech, 2004; 6(2):17-22

Abstract: The paper presents the results of research on the choice of optimal metallic biomaterials (Cr-Ni-Mo steel and titanium) for implants applied in maxillofacial part of cranium. Based on literature the range of cognitive problems has been determined, the solution of which is of prospective importance for the development of new techniques of the osteosynthesis of mandible bone. A program of investigations comprised an analysis of the state of stresses and strains in the mandible and stabilization of miniplates applying the holographic interferometry and the finite element methods. The aim of these investigations was to check whether such implants might warrant a controlled stabilization of the broken elements and whether the yield stresses of both biomaterials are not exceeded.

Key words: miniplate osteosynthesis, metallic biomaterials, mandible fractures

PDF stworzony przez wersję demonstracyjną pdfFactory Pro www.pdffactory.pl/

Cytaty

Powiązane dokumenty

Cooling test was then performed and it was verified both visually and using the computer method, allowing the functional measurement of the flow to be obtained.

Department of Anatomy and Biomechanics FTVS, Charles University, Prague; * Institute of Thermomechanics, Academy of Sciences of the Czech Republic, Prague, Czech Republic Acta

Department of Applied Mechanics, Biomechanical Laboratory, Budapest University of Technology and Economics; * Research Group of Structures, Hungarian Academy of

Our results show quite a complete picture of hemiparetic gait: a reduction of all the basic gait parameters; a reduction of joint excursions in the hip and knee on both

The selected kinematic parameter Xhip, (instantaneous hip displacement) varies little among the swimmers, whereas for the parameter k (describing the variation of

The "standard" Coulomb active pressure wedge consists here of a "pressure" wedge at the wall (green lines) and a "resistance" wedge at the surface (red ones,

Ma atte erriia all a an nd d m me etth ho od dss:: Of the patients treated in our hospital for bone necro- sis of the mandible between January 2005 and June 2010, 16

Szmygin, PKN ICOMOS, Biuro Stołecznego Konserwatora Zabytków Urzędu Miasta Stołecznego Warszawa, Politechnika Lubelska, Warszawa–Lublin 2012, 5.. 2