SGS-THOMSON

B Y T 12 P -600 - > 800

FAST RECOVERY RECTIFIER DIODES

■ VERY HIGH REVERSE VOLTAGE CAPABILITY

■ VERY LOW REVERSE RECOVERY TIME

■ VERY LOW SWITCHING LOSSES

■ LOW NOISE TURN-OFF SWITCHING

SUITABLE A P P L IC A T IO N S

. FREE WHEELING DIODE IN CONVERTERS AND MOTOR CONTROL CIRCUITS

ABSOLUTE RATINGS (limiting values)

Sym bol P aram eter Value Unit

Ifrm Repetitive Peak Forward Current tp < 10ps 150 A

If(RMS) RMS Forward Current 25 A

If(av) Average Forward Current Tease — 10 0°C 8 = 0.5

12 A

Ifsm Surge non Repetitive Forward Current 75 A

P Power Dissipation Tease — 10 0°C 25 W

Tstg Tj

Storage and Junction Temperature Range - 40 to + 150 °C

Sym bol Param eter BYT 12 P-

Unit

600 800

Vrrm Repetitive Peak Reverse Voltage 600 800 V

Vrsm Non Repetitive Peak Reverse Voltage 640 850 V

THERM AL R E S IS TA N C E

S y m b o l P a r a m e te r V a lu e U n it

Rth (j-C) Junction-case 2 °C/W

June 1989 1/5

(2)

BYT 12P-600 -> 800

ELECTRICAL C H A R A C T E R IS TIC S

STATIC CHARACTERISTICS

S y m b o l T e s t C o n d itio n s M in . T y p . M a x . U n it

Ir T, = 25°C Vr = Vrrm 50 pA

Tj = 100°C 2.5 mA

Vf T| = 25°C If = 12A 1.9 V

T | = 100°C 1.8

RECOVERY CHARACTERISTICS

S y m b o l T e s t C o n d itio n s M in . T y p . M a x . U n it

trr

T j

= 25°C

l F

= 1A diF/dt = - 15A/ps VR = 30V 120 ns

IF = 0.5A lR = 1A l r, = 0.25 A 50

TURN -OFF SWITCHING CHARACTERISTICS (Without Series Inductance)

Symbol Parameter Min. Typ. Max. Unit

t|RM d iF /d t

= - 50 A/ps Vcc = 200V

I

f

= 12A Lp < 0.05 pH

T j-1 0 0 "C See figure 11

160 ns

d iF /d t

= -1 0 0 A/ps 100

I

rm d iF /d t

= - 50 A/ps 6 A

d iF /d t

= -1 0 0 A/ps 7.5

TURN -OFF OVERVOLTAGE COEFFICIENT (With Series Inductance)

S y m b o l T e s t C o n d itio n s M in . T y p . M a x . U n it

r - Vrp Vcc

T j = 100°C V c c = 150V If = If(a v) d iF /d t = - 1 2 A /|is L p = 4 |iH S ee F ig u re 12

4

Note : Applicable to BYT 12 P-800 only.

To evaluate the conduction losses use the following equation : V

f

= 1.47 + 0.026 I

f

P = 1.47

x

I

f

(

av

) + 0.026 I

f

2(

rms

>

f Z

T SGS-THOMSON

• *7 # RfflOOia@[i[Ul©TnK@R30eS

2/5

(3)

P (W)

FIGURE 1 : Low frequency power losses versus average current.

FIGURE 3 : Non repetitive peak surge current versus overload duration.

FIGURE 5 : Voltage drop versus forward current.

FIGURE 2 : Peak current versus fora factor.

K

FIGURE 4 : Theraal litpedance versus pulse width.

FIGURE 6 : Recovery charge versus dlp/dt.

[ Z

T SGS-THOMSON

“ ■ / / MUBOIOBJICinilSHDCS

3/5

(4)

BYT 12P-600 -> 800

FIGURE 7 : Recovery tine versus dlp/dt. FIGURE B : Peak reverse current versus dlF/dt.

0 50 100 150

FIGURE 8 : Peak forward voltage versus dlF/dt.

FIGURE 10 : Dynamic parameters versus Junction temperature.

Figure 11 : Turn-off switching characteristics (without series inductance).

SGS-THOMSON

M CH M LB CniaH IC S 4/5

(5)

if

Figure 12 : Turn-off switching characteristics (with series inductance).

7 SCS-THOMSON

“ ■ J f MOWHJCmWBJOS*

5/5

Cytaty

Powiązane dokumenty

Przedmiotem opracowania jest obliczenie i tabelaryczne zestawienie do pusz czal nej obli- czeniowej nośności dla dwóch typów i sześciu grubości ka set ścien nych pra cu ją cych

„oszczędzający tryb życia” przez 6 miesięcy. Sąd Apelacyjny podkreślił, że Sąd Okręgowy miał pełne podstawy w zgromadzonym materiale dowodowym do ustale- nia, że

Dokonanie zmiany ustalonej wartości zamówienia na przebudowę i dostosowanie do potrzeb Zespołu Szkół Niepełnosprawnych budynku Bursy Międzyszkolnej – po

Wypłacić pracownikowi zaniżoną kwotę wynagrodzenia i rozważyć wystąpienie do pracownika o dobrowolny zwrot nadpłaconej kwoty wynagrodzenia lub jej wyegzekwowanie

70005 - Gospodarka gruntami i nieruchomościami zgodnie z pismem Wydziału Infrastruktury Miasta Nr WIM/DGK/ZNM/301/8/06 z dnia 02.02.2006 roku dotyczy zwiększenia wydatków

Figure 12 : Turn-off switching characteristics (with series inductance).

[r]

szość i przyszłość”, która odbyła się pod koniec września w Raciborzu.. Placówki te, zdaniem uczestników konferencji, są mocno niedofinanso-